{"id":400251,"date":"2024-10-20T04:48:28","date_gmt":"2024-10-20T04:48:28","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-802-3cu-2021-3\/"},"modified":"2024-10-26T08:36:21","modified_gmt":"2024-10-26T08:36:21","slug":"ieee-802-3cu-2021-3","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-802-3cu-2021-3\/","title":{"rendered":"IEEE 802.3cu-2021"},"content":{"rendered":"

Amendment Standard – Active. This amendment to IEEE Std 802.3-2018 adds Physical Layer specifications and management parameters for 100 Gb\/s and 400 Gb\/s Ethernet optical interfaces for reaches up to 10 km based on 100 Gb\/s per wavelength optical signaling.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nIEEE Std 802.3cu-2021 Front Cover <\/td>\n<\/tr>\n
2<\/td>\nTitle page <\/td>\n<\/tr>\n
4<\/td>\nImportant Notices and Disclaimers Concerning IEEE Standards Documents <\/td>\n<\/tr>\n
7<\/td>\nParticipants <\/td>\n<\/tr>\n
10<\/td>\nIntroduction <\/td>\n<\/tr>\n
14<\/td>\nContents <\/td>\n<\/tr>\n
19<\/td>\n1. Introduction
1.4 Definitions <\/td>\n<\/tr>\n
20<\/td>\n30. Management
30.5 Layer management for medium attachment units (MAUs)
30.5.1 MAU managed object class
30.5.1.1 MAU attributes
30.5.1.1.2 aMAUType <\/td>\n<\/tr>\n
21<\/td>\n45. Management Data Input\/Output (MDIO) Interface
45.2 MDIO Interface Registers
45.2.1 PMA\/PMD registers
45.2.1.6 PMA\/PMD control 2 register (Register 1.7)
45.2.1.7 PMA\/PMD status 2 register (Register 1.8)
45.2.1.7.4 Transmit fault (1.8.11) <\/td>\n<\/tr>\n
22<\/td>\n45.2.1.7.5 Receive fault (1.8.10)
45.2.1.8 PMD transmit disable register (Register 1.9) <\/td>\n<\/tr>\n
23<\/td>\n45.2.1.21 400G PMA\/PMD extended ability register (Register 1.24)
45.2.1.21.1a1 400GBASE-LR4-6 ability (1.24.9)
45.2.1.21.1a2 400GBASE-FR4 ability (1.24.8) <\/td>\n<\/tr>\n
24<\/td>\n45.2.1.21b 40G\/100G PMA\/PMD extended ability 2 (Register 1.26)
45.2.1.21b.3a 100GBASE-LR1 ability (1.26.5)
45.2.1.21b.3b 100GBASE-FR1 ability (1.26.4) <\/td>\n<\/tr>\n
25<\/td>\n78. Energy-Efficient Ethernet (EEE)
78.1 Overview
78.1.4 PHY types optionally supporting EEE <\/td>\n<\/tr>\n
26<\/td>\n80. Introduction to 40 Gb\/s and 100 Gb\/s networks
80.1 Overview
80.1.3 Relationship of 40 Gigabit and 100 Gigabit Ethernet to the ISO OSI reference model
80.1.4 Nomenclature <\/td>\n<\/tr>\n
27<\/td>\n80.1.5 Physical Layer signaling systems
80.2 Summary of 40 Gigabit and 100 Gigabit Ethernet sublayers
80.2.3 Forward Error Correction (FEC) sublayers <\/td>\n<\/tr>\n
28<\/td>\n80.4 Delay constraints <\/td>\n<\/tr>\n
29<\/td>\n91. Reed-Solomon Forward Error Correction (RS-FEC) sublayer for 100GBASE-R PHYs
91.5 Functions within the RS-FEC sublayer
91.5.2.7 Reed-Solomon encoder
91.5.3 Receive function
91.5.3.3 Reed-Solomon decoder
91.5.3.3.1 FEC Degraded SER (optional) <\/td>\n<\/tr>\n
30<\/td>\n91.6 RS-FEC MDIO function mapping
91.6.2a four_lane_pmd <\/td>\n<\/tr>\n
31<\/td>\n91.7 Protocol implementation conformance statement (PICS) proforma for Clause 91, Reed-Solomon Forward Error Correction (RS-FEC) sublayer for 100GBASE-R PHYs
91.7.3 Major capabilities\/options
91.7.4 PICS proforma tables for Reed-Solomon Forward Error Correction (RS-FEC) sublayer for 100GBASE-R PHYs
91.7.4.1 Transmit function <\/td>\n<\/tr>\n
32<\/td>\n91.7.4.2 Receive function <\/td>\n<\/tr>\n
33<\/td>\n116. Introduction to 200 Gb\/s and 400 Gb\/s networks
116.1 Overview
116.1.2 Relationship of 200 Gigabit and 400 Gigabit Ethernet to the ISO OSI reference model
116.1.3 Nomenclature <\/td>\n<\/tr>\n
34<\/td>\n116.1.4 Physical Layer signaling systems
116.4 Delay constraints <\/td>\n<\/tr>\n
35<\/td>\n116.5 Skew constraints <\/td>\n<\/tr>\n
37<\/td>\n140. Physical Medium Dependent (PMD) sublayer and medium, type 100GBASE-DR, 100GBASE-FR1, and 100GBASE-LR1
140.1 Overview <\/td>\n<\/tr>\n
38<\/td>\n140.2 Physical Medium Dependent (PMD) service interface <\/td>\n<\/tr>\n
39<\/td>\n140.3 Delay and Skew
140.3.1 Delay constraints
140.5 PMD functional specifications
140.5.1 PMD block diagram
140.6 PMD to MDI optical specifications for 100GBASE-DR, 100GBASE-FR1, and 100GBASE-LR1 <\/td>\n<\/tr>\n
40<\/td>\n140.6.1 100GBASE-DR, 100GBASE-FR1, and 100GBASE-LR1 transmitter optical specifications <\/td>\n<\/tr>\n
42<\/td>\n140.6.2 100GBASE-DR, 100GBASE-FR1, and 100GBASE-LR1 receive optical specifications <\/td>\n<\/tr>\n
44<\/td>\n140.6.3 100GBASE-DR, 100GBASE-FR1, and 100GBASE-LR1 illustrative link power budgets <\/td>\n<\/tr>\n
47<\/td>\n140.7 Definition of optical parameters and measurement methods
140.7.1 Test patterns for optical parameters
140.7.5 Transmitter and dispersion eye closure for PAM4 (TDECQ) <\/td>\n<\/tr>\n
48<\/td>\n140.7.5.1 TDECQ reference equalizer
140.7.5.2 Channel requirements
140.7.5a Transmitter eye closure for PAM4 (TECQ) <\/td>\n<\/tr>\n
49<\/td>\n140.7.5b Over\/under-shoot
140.7.5c Transmitter power excursion <\/td>\n<\/tr>\n
50<\/td>\n140.7.8 Relative intensity noise (RIN15.5xOMA)
140.7.9 Receiver sensitivity
140.7.9.1 Receiver sensitivity for 100GBASE-DR
140.7.9.2 Receiver sensitivity for 100GBASE-FR1 and 100GBASE-LR1 <\/td>\n<\/tr>\n
51<\/td>\n140.7.10 Stressed receiver sensitivity
140.8 Safety, installation, environment, and labeling
140.8.2 Laser safety
140.8.4 Environment
140.8.5 Electromagnetic emission <\/td>\n<\/tr>\n
52<\/td>\n140.9 Fiber optic cabling model
140.10 Characteristics of the fiber optic cabling (channel) <\/td>\n<\/tr>\n
53<\/td>\n140.10.1 Optical fiber cable
140.10.2 Optical fiber connection
140.10.2.1 Connection insertion loss
140.10.2.2 Maximum discrete reflectance <\/td>\n<\/tr>\n
54<\/td>\n140.10.3 Medium Dependent Interface (MDI)
140.10a Interoperation between 100GBASE-DR, 100GBASE-FR1, and 100GBASE-LR1
140.10a.1 Interoperation between 100GBASE-FR1 and 100GBASE-DR <\/td>\n<\/tr>\n
55<\/td>\n140.10a.2 Interoperation between 100GBASE-LR1 and 100GBASE-DR
140.10a.3 Interoperation between 100GBASE-LR1 and 100GBASE-FR1 <\/td>\n<\/tr>\n
56<\/td>\n140.11 Protocol implementation conformance statement (PICS) proforma for Clause 140, Physical Medium Dependent (PMD) sublayer and medium, types 100GBASE-DR, 100GBASE-FR1, and 100GBASE-LR1
140.11.1 Introduction
140.11.2 Identification
140.11.2.2 Protocol summary <\/td>\n<\/tr>\n
57<\/td>\n140.11.3 Major capabilities\/options
140.11.4 PICS proforma tables for Physical Medium Dependent (PMD) sublayer and medium, type 100GBASE-DR, 100GBASE-FR1, and 100GBASE-LR1
140.11.4.3 PMD to MDI optical specifications for 100GBASE-DR
140.11.4.3a PMD to MDI optical specifications for 100GBASE-FR1 <\/td>\n<\/tr>\n
58<\/td>\n140.11.4.3b PMD to MDI optical specifications for 100GBASE-LR1
140.11.4.4 Optical measurement methods <\/td>\n<\/tr>\n
59<\/td>\n140.11.4.6 Characteristics of the fiber optic cabling and MDMDI . <\/td>\n<\/tr>\n
60<\/td>\n151. Physical Medium Dependent (PMD) sublayer and medium, type 400GBASE-FR4 and 400GBASE-LR4-6
151.1 Overview <\/td>\n<\/tr>\n
61<\/td>\n151.1.1 Bit error ratio
151.2 Physical Medium Dependent (PMD) service interface <\/td>\n<\/tr>\n
62<\/td>\n151.3 Delay and Skew
151.3.1 Delay constraints
151.3.2 Skew constraints <\/td>\n<\/tr>\n
63<\/td>\n151.4 PMD MDIO function mapping
151.5 PMD functional specifications
151.5.1 PMD block diagram <\/td>\n<\/tr>\n
64<\/td>\n151.5.2 PMD transmit function
151.5.3 PMD receive function <\/td>\n<\/tr>\n
65<\/td>\n151.5.4 PMD global signal detect function
151.5.5 PMD lane-by-lane signal detect function
151.5.6 PMD reset function
151.5.7 PMD global transmit disable function (optional) <\/td>\n<\/tr>\n
66<\/td>\n151.5.8 PMD lane-by-lane transmit disable function
151.5.9 PMD fault function (optional)
151.5.10 PMD transmit fault function (optional)
151.5.11 PMD receive fault function (optional) <\/td>\n<\/tr>\n
67<\/td>\n151.6 Wavelength-division-multiplexed lane assignments
151.7 PMD to MDI optical specifications for 400GBASE-FR4 and 400GBASE-LR4-6
151.7.1 400GBASE-FR4 and 400GBASE-LR4-6 transmitter optical specifications <\/td>\n<\/tr>\n
69<\/td>\n151.7.2 400GBASE-FR4 and 400GBASE-LR4-6 receive optical specifications <\/td>\n<\/tr>\n
71<\/td>\n151.7.3 400GBASE-FR4 and 400GBASE-LR4-6 illustrative link power budgets <\/td>\n<\/tr>\n
73<\/td>\n151.8 Definition of optical parameters and measurement methods
151.8.1 Test patterns for optical parameters <\/td>\n<\/tr>\n
74<\/td>\n151.8.2 Wavelength and side mode suppression ratio (SMSR)
151.8.3 Average optical power
151.8.4 Outer Optical Modulation Amplitude (OMAouter)
151.8.5 Transmitter and dispersion eye closure for PAM4 (TDECQ)
151.8.5.1 Channel requirements <\/td>\n<\/tr>\n
75<\/td>\n151.8.6 Transmitter eye closure for PAM4 (TECQ)
151.8.7 Over\/under-shoot
151.8.8 Transmitter power excursion
151.8.9 Extinction ratio
151.8.10 Transmitter transition time <\/td>\n<\/tr>\n
76<\/td>\n151.8.11 Relative intensity noise (RIN17.1OMA and RIN15.6OMA)
151.8.12 Receiver sensitivity <\/td>\n<\/tr>\n
77<\/td>\n151.8.13 Stressed receiver sensitivity
151.9 Safety, installation, environment, and labeling
151.9.1 General safety
151.9.2 Laser safety
151.9.3 Installation <\/td>\n<\/tr>\n
78<\/td>\n151.9.4 Environment
151.9.5 Electromagnetic emission
151.9.6 Temperature, humidity, and handling
151.9.7 PMD labeling requirements
151.10 Fiber optic cabling model <\/td>\n<\/tr>\n
79<\/td>\n151.11 Characteristics of the fiber optic cabling (channel)
151.11.1 Optical fiber cable
151.11.2 Optical fiber connection <\/td>\n<\/tr>\n
80<\/td>\n151.11.2.1 Connection insertion loss
151.11.2.2 Maximum discrete reflectance
151.11.3 Medium Dependent Interface (MDI) requirements
151.12 Interoperation between 400GBASE-LR4-6 and 400GBASE-FR4 <\/td>\n<\/tr>\n
82<\/td>\n151.13 Protocol implementation conformance statement (PICS) proforma for Clause 151, Physical Medium Dependent (PMD) sublayer and medium, type 400GBASE-FR4 and 400GBASE-LR4-6
151.13.1 Introduction
151.13.2 Identification
151.13.2.1 Implementation identification
151.13.2.2 Protocol summary <\/td>\n<\/tr>\n
83<\/td>\n151.13.3 Major capabilities\/options
151.13.4 PICS proforma tables for Physical Medium Dependent (PMD) sublayer and medium, type 400GBASE-FR4 and 400GBASE-LR4-6
151.13.4.1 PMD functional specifications <\/td>\n<\/tr>\n
84<\/td>\n151.13.4.2 Management functions <\/td>\n<\/tr>\n
85<\/td>\n151.13.4.3 PMD to MDI optical specifications for 400GBASE-FR4
151.13.4.4 PMD to MDI optical specifications for 400GBASE-LR4-6
151.13.4.5 Optical measurement methods <\/td>\n<\/tr>\n
86<\/td>\n151.13.4.6 Environmental specifications
151.13.4.7 Characteristics of the fiber optic cabling and MDI <\/td>\n<\/tr>\n
87<\/td>\nBack Cover <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

IEEE Standard for Ethernet – Amendment 11: Physical Layers and Management Parameters for 100 Gb\/s and 400 Gb\/s Operation over Single-Mode Fiber at 100 Gb\/s per Wavelength<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
IEEE<\/b><\/a><\/td>\n2021<\/td>\n87<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":400253,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2644],"product_tag":[],"class_list":{"0":"post-400251","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ieee","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/400251","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/400253"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=400251"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=400251"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=400251"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}