{"id":403381,"date":"2024-10-20T05:05:51","date_gmt":"2024-10-20T05:05:51","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-iso-ts-128352022-tc\/"},"modified":"2024-10-26T09:05:08","modified_gmt":"2024-10-26T09:05:08","slug":"bsi-pd-iso-ts-128352022-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-iso-ts-128352022-tc\/","title":{"rendered":"BSI PD ISO\/TS 12835:2022 – TC"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
246<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
252<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
253<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
255<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
259<\/td>\n | 4 Abbreviated terms and symbols 4.1 Abbreviated terms <\/td>\n<\/tr>\n | ||||||
260<\/td>\n | 4.2 Symbols <\/td>\n<\/tr>\n | ||||||
261<\/td>\n | 5 Program overview 5.1 Illustrations of selected definitions 5.2 Program flowchart <\/td>\n<\/tr>\n | ||||||
262<\/td>\n | 6 Overview and fundamental assumptions 6.1 General 6.2 Main features 6.2.1 Purpose <\/td>\n<\/tr>\n | ||||||
263<\/td>\n | 6.2.2 Applicability to service conditions 6.2.3 Rationale for development 6.2.4 Subject of evaluation 6.2.5 Application severity levels <\/td>\n<\/tr>\n | ||||||
264<\/td>\n | 6.3 Assessment philosophy and principles 6.3.1 Fundamental principles <\/td>\n<\/tr>\n | ||||||
265<\/td>\n | 6.3.2 Conservative evaluation procedure 6.3.3 Mandatory and optional tasks <\/td>\n<\/tr>\n | ||||||
266<\/td>\n | 6.3.4 Use of analysis and physical testing 6.3.5 Performance measures 6.3.6 Assessment criteria <\/td>\n<\/tr>\n | ||||||
267<\/td>\n | 6.3.7 Task outcomes \u2014 data categories 6.3.8 Prior evaluation data 6.3.9 Treatment of confidential design information <\/td>\n<\/tr>\n | ||||||
268<\/td>\n | 6.3.10 Interpretation of evaluation results 6.3.11 Avoiding perception of conflict of interest 6.4 Evaluation variables 6.4.1 Connection loading 6.4.2 Impacts of contributing variables <\/td>\n<\/tr>\n | ||||||
270<\/td>\n | 6.4.3 Pin-box interferences and tapers 6.4.4 Material yield strength <\/td>\n<\/tr>\n | ||||||
271<\/td>\n | 6.5 Evaluation procedure 6.5.1 Safety standards 6.5.2 Seepage assessment \u2014 random variations 6.5.3 Seepage rate thresholds <\/td>\n<\/tr>\n | ||||||
272<\/td>\n | 6.5.4 Seal isolation 6.5.5 Dope entrapment 6.5.6 Thermal cycle test \u2014 bake-out and hold durations <\/td>\n<\/tr>\n | ||||||
273<\/td>\n | 6.5.7 Pressure and temperature loading in thermal cycle test and analysis 6.5.8 Dependence of material strength on temperature <\/td>\n<\/tr>\n | ||||||
274<\/td>\n | 6.6 Scope of reporting 7 Program roles and proprietary design information 7.1 Program execution roles 7.2 Proprietary connection design information <\/td>\n<\/tr>\n | ||||||
275<\/td>\n | 8 Conformance requirements 8.1 Conformant evaluation program 8.2 Program non-conformances <\/td>\n<\/tr>\n | ||||||
276<\/td>\n | 8.3 Performance acceptance 8.4 Conformance of results from previous evaluations 8.5 Use of data from previous evaluations <\/td>\n<\/tr>\n | ||||||
277<\/td>\n | 8.6 Conformance to lower ASLs 9 Application severity levels 9.1 Thermal well load path <\/td>\n<\/tr>\n | ||||||
279<\/td>\n | 9.2 Temperature as controlling parameter <\/td>\n<\/tr>\n | ||||||
280<\/td>\n | 9.3 Specifications for application severity levels <\/td>\n<\/tr>\n | ||||||
281<\/td>\n | 9.4 Selection of application severity level 10 Program blocks and tasks 10.1 Evaluation procedure overview <\/td>\n<\/tr>\n | ||||||
285<\/td>\n | 10.2 Critical path tasks <\/td>\n<\/tr>\n | ||||||
286<\/td>\n | 11 Program specifications 11.1 Task overview 11.2 Identification of program roles <\/td>\n<\/tr>\n | ||||||
287<\/td>\n | 11.3 Identification of candidate connection <\/td>\n<\/tr>\n | ||||||
288<\/td>\n | 11.4 Program options <\/td>\n<\/tr>\n | ||||||
289<\/td>\n | 11.5 Data from prior evaluations 12 Determination of biased test population 12.1 Task overview <\/td>\n<\/tr>\n | ||||||
290<\/td>\n | 12.2 Initial material property characterization 12.2.1 Task description, definitions, methods <\/td>\n<\/tr>\n | ||||||
291<\/td>\n | 12.2.2 Testing conditions and scope <\/td>\n<\/tr>\n | ||||||
293<\/td>\n | 12.2.3 Procedure for tensile tests <\/td>\n<\/tr>\n | ||||||
294<\/td>\n | 12.2.4 Interpretation and processing of tensile test results <\/td>\n<\/tr>\n | ||||||
299<\/td>\n | 12.3 Specimen configuration analysis 12.3.1 Task description <\/td>\n<\/tr>\n | ||||||
300<\/td>\n | 12.3.2 Modelling and reporting requirements <\/td>\n<\/tr>\n | ||||||
301<\/td>\n | 12.3.3 Nominal reference case <\/td>\n<\/tr>\n | ||||||
302<\/td>\n | 12.3.4 Worst-case geometry configurations <\/td>\n<\/tr>\n | ||||||
304<\/td>\n | 12.3.5 Seal taper analysis <\/td>\n<\/tr>\n | ||||||
305<\/td>\n | 12.3.6 Impacts of material property variations <\/td>\n<\/tr>\n | ||||||
308<\/td>\n | 12.3.7 Make-up torque for sealability tests <\/td>\n<\/tr>\n | ||||||
310<\/td>\n | 12.3.8 Test versus production specimens 13 Specimen procurement 13.1 Task overview <\/td>\n<\/tr>\n | ||||||
311<\/td>\n | 13.2 Specimen pipe procurement 13.3 Material property verification 13.3.1 Task description 13.3.2 Specimens for tensile verification tests <\/td>\n<\/tr>\n | ||||||
312<\/td>\n | 13.3.3 Scope of tensile verification tests <\/td>\n<\/tr>\n | ||||||
313<\/td>\n | 13.3.4 Coefficient of thermal expansion verification test <\/td>\n<\/tr>\n | ||||||
314<\/td>\n | 13.4 Test specimen machining and gauging 13.4.1 General requirements 13.4.2 Specimen naming convention <\/td>\n<\/tr>\n | ||||||
315<\/td>\n | 13.4.3 Specimen length and length-reference requirements <\/td>\n<\/tr>\n | ||||||
316<\/td>\n | 13.4.4 Geometrical configurations 13.4.5 Mother pipe for specimens <\/td>\n<\/tr>\n | ||||||
317<\/td>\n | 13.4.6 Specimen machining tolerances <\/td>\n<\/tr>\n | ||||||
319<\/td>\n | 13.5 Markings 13.6 Specimen geometry verification 13.6.1 Gauging inspection scope <\/td>\n<\/tr>\n | ||||||
320<\/td>\n | 13.6.2 Inspection extent \u2013 example cases 13.6.3 Geometry inspection guidelines <\/td>\n<\/tr>\n | ||||||
321<\/td>\n | 13.7 Procurement and quality control of connection interfacial components 13.8 Specimen handling and storage 13.8.1 Handling recommendations <\/td>\n<\/tr>\n | ||||||
322<\/td>\n | 13.8.2 Treatment of damaged specimens 14 Full-scale physical tests and supplementary analyses 14.1 Task overview <\/td>\n<\/tr>\n | ||||||
323<\/td>\n | 14.2 Full-scale tests – general requirements 14.2.1 Ambient temperature at test site 14.2.2 Calibration of instrumentation <\/td>\n<\/tr>\n | ||||||
324<\/td>\n | 14.2.3 Disabling of secondary seals 14.2.4 Seepage measurement and rate definitions <\/td>\n<\/tr>\n | ||||||
326<\/td>\n | 14.2.5 Load application rates 14.2.6 Excluded connections <\/td>\n<\/tr>\n | ||||||
327<\/td>\n | 14.3 Galling resistance test 14.3.1 Task description <\/td>\n<\/tr>\n | ||||||
328<\/td>\n | 14.3.2 Rationale and objectives 14.3.3 Make-break specimens 14.3.4 Scope of galling resistance test <\/td>\n<\/tr>\n | ||||||
329<\/td>\n | 14.3.5 Set-up and instrumentation <\/td>\n<\/tr>\n | ||||||
330<\/td>\n | 14.3.6 Test procedure <\/td>\n<\/tr>\n | ||||||
331<\/td>\n | 14.3.7 Performance assessment <\/td>\n<\/tr>\n | ||||||
332<\/td>\n | 14.3.8 Reporting 14.4 Thermal cycle test 14.4.1 Task description 14.4.2 Rationale and objectives <\/td>\n<\/tr>\n | ||||||
333<\/td>\n | 14.4.3 Thermal cycle specimens 14.4.4 Scope of thermal cycle test <\/td>\n<\/tr>\n | ||||||
336<\/td>\n | 14.4.5 Mechanical strain compensations <\/td>\n<\/tr>\n | ||||||
339<\/td>\n | 14.4.6 Set-up and instrumentation <\/td>\n<\/tr>\n | ||||||
345<\/td>\n | 14.4.7 Test procedure <\/td>\n<\/tr>\n | ||||||
350<\/td>\n | 14.4.8 Performance assessment <\/td>\n<\/tr>\n | ||||||
351<\/td>\n | 14.4.9 Selection of cycled specimens for bend test and limit-strain test 14.4.10 Reporting 14.5 Bending evaluation <\/td>\n<\/tr>\n | ||||||
352<\/td>\n | 14.6 Limit-strain test 14.6.1 Task description 14.6.2 Rationale and objectives <\/td>\n<\/tr>\n | ||||||
353<\/td>\n | 14.6.3 Limit-strain specimens 14.6.4 Mandatory test description <\/td>\n<\/tr>\n | ||||||
355<\/td>\n | 14.6.5 Set-up and instrumentation <\/td>\n<\/tr>\n | ||||||
357<\/td>\n | 14.6.6 Mandatory test procedure <\/td>\n<\/tr>\n | ||||||
362<\/td>\n | 14.6.7 Performance assessment 14.6.8 Reporting 14.7 As-tested configuration analysis 15 Evaluation and inspection reports 15.1 Reporting deliverables <\/td>\n<\/tr>\n | ||||||
363<\/td>\n | 15.2 Reporting scope and contents <\/td>\n<\/tr>\n | ||||||
367<\/td>\n | 15.3 Reporting templates <\/td>\n<\/tr>\n | ||||||
368<\/td>\n | Annex A (informative) FEA modelling guidelines <\/td>\n<\/tr>\n | ||||||
378<\/td>\n | Annex B (informative) Derivations of formulae – Strain compensation factors <\/td>\n<\/tr>\n | ||||||
387<\/td>\n | Annex C (informative) Program role assignments and responsibilities <\/td>\n<\/tr>\n | ||||||
394<\/td>\n | Annex D (informative) Optional program selections, tasks, and procedures <\/td>\n<\/tr>\n | ||||||
417<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Tracked Changes. Qualification of casing connections for thermal wells<\/b><\/p>\n |