{"id":411357,"date":"2024-10-20T05:44:49","date_gmt":"2024-10-20T05:44:49","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-60384-192022-tc\/"},"modified":"2024-10-26T10:37:29","modified_gmt":"2024-10-26T10:37:29","slug":"bs-en-iec-60384-192022-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-60384-192022-tc\/","title":{"rendered":"BS EN IEC 60384-19:2022 – TC"},"content":{"rendered":"
IEC 60384-19:2022 is applicable to fixed surface mount capacitors for direct current, with metallized electrodes and polyethylene-terephthalate dielectric for use in electronic equipment. These capacitors have metallized connecting pads or soldering strips and are intended to be mounted directly onto printed boards or onto substrates for hybrid circuits. These capacitors can have “self-healing properties” depending on conditions of use. They are primarily intended for applications where the AC component is small with respect to the rated voltage. This part of IEC 60384 specifies preferred ratings and characteristics, and selects from IEC 60384?1:2021 the appropriate quality assessment procedures, tests and measuring methods, and gives general performance requirements for this type of capacitor. Test severities and requirements specified in detail specifications referring to this sectional specification are of an equal or higher performance level. Lower performance levels are not permitted. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384?14. This edition includes the following significant technical changes with respect to the previous edition: <\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | 30462593 <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | A-30413490 <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | Annex ZA (normative)Normative references to international publicationswith their corresponding European publications <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | Blank Page <\/td>\n<\/tr>\n | ||||||
77<\/td>\n | English CONTENTS <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | 3 Terms and definition 4 Preferred ratings and characteristics 4.1 Preferred climatic categories 4.2 Preferred values of ratings 4.2.1 Nominal capacitance (CN) 4.2.2 Tolerance on nominal capacitance <\/td>\n<\/tr>\n | ||||||
84<\/td>\n | 4.2.3 Rated voltage (UR) 4.2.4 Category voltage (UC) 4.2.5 Rated temperature 5 Test and measurement procedures 5.1 General 5.2 Mounting 5.2.1 Initial inspections 5.2.2 Mounting method 5.2.3 Final inspections after mounting Tables Table 1 \u2013 Percentage limit of the rated voltage at AC voltage frequency <\/td>\n<\/tr>\n | ||||||
85<\/td>\n | 5.3 Visual examination and check of dimensions 5.3.1 General 5.3.2 Visual examination and check of dimensions 5.3.3 Requirements 5.4 Electrical tests 5.4.1 Voltage proof Table 2 \u2013 Test voltages <\/td>\n<\/tr>\n | ||||||
86<\/td>\n | 5.4.2 Capacitance 5.4.3 Tangent of loss angle (tan \u03b4) Table 3 \u2013 Tangent of loss angle limits <\/td>\n<\/tr>\n | ||||||
87<\/td>\n | 5.4.4 Insulation resistance <\/td>\n<\/tr>\n | ||||||
88<\/td>\n | 5.5 Shear test 5.5.1 General 5.5.2 Final inspections 5.6 Substrate bending test 5.6.1 General Table 4 \u2013 Requirements regarding insulation resistance Table 5 \u2013 Correction factor dependent on temperature <\/td>\n<\/tr>\n | ||||||
89<\/td>\n | 5.6.2 Initial inspections 5.6.3 Final inspections and requirements 5.7 Resistance to soldering heat 5.7.1 General 5.7.2 Initial inspections 5.7.3 Test conditions 5.7.4 Recovery 5.7.5 Final inspections and requirements 5.8 Solderability 5.8.1 General <\/td>\n<\/tr>\n | ||||||
90<\/td>\n | 5.8.2 Test conditions 5.8.3 Final inspections and requirements 5.9 Rapid change of temperature 5.9.1 General 5.9.2 Initial inspections 5.9.3 Test conditions 5.9.4 Final inspections and requirements 5.10 Climatic sequence 5.10.1 General 5.10.2 Initial inspections 5.10.3 Dry heat <\/td>\n<\/tr>\n | ||||||
91<\/td>\n | 5.10.4 Damp heat, cyclic, test Db, first cycle 5.10.5 Cold 5.10.6 Damp heat, cyclic, test Db, remaining cycles 5.10.7 Recovery 5.10.8 Final inspections and requirements 5.11 Damp heat, steady state 5.11.1 General 5.11.2 Initial inspections 5.11.3 Test conditions 5.11.4 Recovery 5.11.5 Final inspections and requirements <\/td>\n<\/tr>\n | ||||||
92<\/td>\n | 5.12 Endurance 5.12.1 General 5.12.2 Initial inspections 5.12.3 Test conditions 5.12.4 Final inspections and requirements 5.13 Charge and discharge 5.13.1 General 5.13.2 Initial inspections Table 6 \u2013 Endurance test conditions <\/td>\n<\/tr>\n | ||||||
93<\/td>\n | 5.13.3 Test conditions 5.13.4 Recovery 5.13.5 Final inspections and requirements 5.14 Component solvent resistance (if required) 5.14.1 General 5.14.2 Final inspections and requirements 5.15 Solvent resistance of marking (if required) 5.15.1 General 5.15.2 Final inspections and requirements 6 Marking 6.1 General 6.2 Information for marking <\/td>\n<\/tr>\n | ||||||
94<\/td>\n | 6.3 Marking on capacitors 6.4 Marking on packaging 7 Information to be given in a detail specification 7.1 General 7.2 Outline drawing and dimensions <\/td>\n<\/tr>\n | ||||||
95<\/td>\n | 7.3 Mounting 7.4 Ratings and characteristics 7.4.1 General 7.4.2 Nominal capacitance range 7.4.3 Particular characteristics 7.4.4 Soldering 7.5 Marking 8 Quality assessment procedures 8.1 Primary stage of manufacture 8.2 Structurally similar components 8.3 Certified test records of released lots 8.4 Qualification approval procedures 8.4.1 General <\/td>\n<\/tr>\n | ||||||
96<\/td>\n | 8.4.2 Qualification approval on the basis of the fixed sample size procedure <\/td>\n<\/tr>\n | ||||||
97<\/td>\n | Table 7 \u2013 Test and sampling plan for qualification approvalAssessment level EZ <\/td>\n<\/tr>\n | ||||||
98<\/td>\n | Table 8 \u2013 Test schedule for qualification approval <\/td>\n<\/tr>\n | ||||||
103<\/td>\n | Annex A (normative)Quality conformance inspection A.1 Formation of inspection lots A.2 Test schedule A.3 Delayed delivery A.4 Assessment levels <\/td>\n<\/tr>\n | ||||||
104<\/td>\n | Table A.1 \u2013 Lot-by-lot inspection <\/td>\n<\/tr>\n | ||||||
105<\/td>\n | Table A.2 \u2013 Periodic inspection <\/td>\n<\/tr>\n | ||||||
110<\/td>\n | Annex X (informative)Cross-references to the previous edition of this document Table X.1 \u2013 Cross-references <\/td>\n<\/tr>\n | ||||||
112<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Tracked Changes. Fixed capacitors for use in electronic equipment – Sectional specification: Fixed metallized polyethylene terephthalate film dielectric surface mount DC capacitors<\/b><\/p>\n |