{"id":418030,"date":"2024-10-20T06:19:00","date_gmt":"2024-10-20T06:19:00","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-iec-ts-627382018-2\/"},"modified":"2024-10-26T11:46:57","modified_gmt":"2024-10-26T11:46:57","slug":"bsi-pd-iec-ts-627382018-2","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-iec-ts-627382018-2\/","title":{"rendered":"BSI PD IEC TS 62738:2018"},"content":{"rendered":"

This document sets out general guidelines and recommendations for the design and installation of ground-mounted photovoltaic (PV) power plants. A PV power plant is defined within this document as a grid-connected, ground-mounted system comprising multiple PV arrays and interconnected directly to a utility\u2019s medium voltage or high voltage grid. Additional criteria is that PV power plants are restricted from access by non-qualified persons and are continuously monitored for safety and protection, either by on-site personnel or by active remote monitoring. Technical areas addressed are those that largely distinguish PV power plants from smaller, more conventional installations, including ground mounted array configurations, cable routing methods, cable selection, overcurrent protection strategies, equipotential bonding over large geographical areas, and equipment considerations.<\/p>\n

Safety and design requirements are referenced to the applicable requirements of IEC 62548 to address distinct differences relative to the design requirements for residential, commercial and other non-power plant applications. In general, existing standards are referenced wherever possible for uniformity. Emphasis is placed on systems employing d.c. string based systems using large scale central inverters or 3-phase string inverters, but relevant sections are also applicable to systems employing a.c. modules or d.c.\/d.c. converters. Medium voltage transformers, switchgear, collection systems, substations, utility interconnection, auxiliary loads, energy storage systems, and communication services are addressed, but discussion is mostly limited to recommended references to other standards and requirements.<\/p>\n

Rooftop-mounted systems, building integrated PV (BIPV) and building applied PV (BAPV) are not included in the scope of this document. The principles of restricted-access power plants are not compatible with systems on buildings, which are used for purposes other than power generation.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nundefined <\/td>\n<\/tr>\n
4<\/td>\nCONTENTS <\/td>\n<\/tr>\n
7<\/td>\nFOREWORD <\/td>\n<\/tr>\n
9<\/td>\nINTRODUCTION <\/td>\n<\/tr>\n
10<\/td>\n1 Scope
2 Normative references <\/td>\n<\/tr>\n
13<\/td>\n3 Terms and definitions
4 Compliance with IEC 62548 <\/td>\n<\/tr>\n
14<\/td>\n5 PV array system configuration
5.1 General
5.2 Earthing configurations
5.2.1 General
5.2.2 Use of un-earthed d.c. circuits
5.2.3 Use of high-ohmic earthed d.c. circuits
5.2.4 Use of functionally earthed d.c. circuits
5.3 Array electrical diagrams
5.3.1 General <\/td>\n<\/tr>\n
15<\/td>\n5.3.2 Multiple sub-array configurations
Figures
Figure 1 \u2013 PV array diagram \u2013 multiple parallel string case with array divided into sub-arrays <\/td>\n<\/tr>\n
16<\/td>\nFigure 2 \u2013 PV array example using a PCE with multiple MPPT d.c. inputs <\/td>\n<\/tr>\n
17<\/td>\n5.3.3 Single array configuration
Figure 3 \u2013 PV array using a PCE with multiple d.c. inputs internallyconnected to a common d.c. bus <\/td>\n<\/tr>\n
18<\/td>\n5.3.4 Combiner boxes and string wiring harnesses
5.3.5 Series-parallel configuration
Figure 4 \u2013 PV array diagram \u2013 multiple parallel string example <\/td>\n<\/tr>\n
19<\/td>\n5.4 Energy storage in PV power plants
5.5 Array physical configurations
5.5.1 Fixed tilt arrays
5.5.2 Adjustable tilt arrays
Figure 5 \u2013 Example power plant with fixed tilt array <\/td>\n<\/tr>\n
20<\/td>\n5.5.3 Single axis tracking arrays
5.5.4 Two-axis tracking arrays
5.5.5 Concentrating PV arrays
5.5.6 Central inverter configurations <\/td>\n<\/tr>\n
21<\/td>\n5.5.7 String or module inverter configurations
Figure 6 \u2013 Example layout of power plant central inverter based array <\/td>\n<\/tr>\n
22<\/td>\n5.6 Mechanical design
5.6.1 Mechanical loads on PV structures
5.6.2 Wind
5.6.3 Snow
5.6.4 Thermal expansion
5.6.5 Flooding
Figure 7 \u2013 Example layout of power plant with string inverters <\/td>\n<\/tr>\n
23<\/td>\n5.6.6 Seismic activity
5.6.7 Corrosion
5.6.8 Access
6 Safety issues
6.1 General <\/td>\n<\/tr>\n
24<\/td>\n6.2 Restricted access
6.2.1 General
6.2.2 Access to components
6.3 Protection against overcurrent
6.3.1 DC overcurrent protection devices
6.3.2 Requirement for string overcurrent protection
6.3.3 String overcurrent protection sizing <\/td>\n<\/tr>\n
25<\/td>\n6.3.4 PV sub-array and array overcurrent protection <\/td>\n<\/tr>\n
26<\/td>\n6.4 Protection against the effects of insulation faults
6.5 Protection against effects of lightning and overvoltage
6.5.1 Lightning protection <\/td>\n<\/tr>\n
27<\/td>\nFigure 8 \u2013 Example ground plan for equipotential bondingof a PV array field <\/td>\n<\/tr>\n
28<\/td>\n6.5.2 Protection against overvoltage
6.6 Protection against fire
6.6.1 Earth-fault protection
6.6.2 Protection against arcing currents
7 Selection and erection of electrical equipment
7.1 General <\/td>\n<\/tr>\n
29<\/td>\n7.2 PV array design voltage
7.2.1 PV array maximum voltage
7.2.2 Considerations due to inverter MPPT voltage window
7.2.3 Considerations due to inverter efficiency
7.3 Component requirements
7.3.1 General <\/td>\n<\/tr>\n
30<\/td>\n7.3.2 PV combiner boxes <\/td>\n<\/tr>\n
31<\/td>\n7.3.3 Disconnectors and switch-disconnectors <\/td>\n<\/tr>\n
32<\/td>\n7.3.4 Cables <\/td>\n<\/tr>\n
34<\/td>\nFigure 9 \u2013 Example of above-ground cable tray configurations for PV plants <\/td>\n<\/tr>\n
36<\/td>\nFigure 10 \u2013 Example trench diagram with cables in ducts <\/td>\n<\/tr>\n
37<\/td>\nFigure 11 \u2013 Example trench diagram with direct buried d.c.and communication cables <\/td>\n<\/tr>\n
38<\/td>\nFigure 12 \u2013 Example trench diagram with direct buried medium voltage a.c.and communication cables <\/td>\n<\/tr>\n
39<\/td>\n7.3.5 Trackers
8 Acceptance
8.1 General
8.2 Monitoring
8.3 Commissioning tests
8.4 Preliminary performance acceptance test
8.5 Final performance acceptance test <\/td>\n<\/tr>\n
40<\/td>\n9 Maintenance
10 Marking and documentation
10.1 General
10.2 Labelling and identification
10.2.1 General
10.2.2 Labelling of disconnection devices and combiner boxes
10.3 Documentation <\/td>\n<\/tr>\n
41<\/td>\n11 Medium and high voltage a.c. systems
11.1 General
11.2 Selection of a.c. collection system voltage
11.3 Collection system configurations
11.3.1 General
11.3.2 Radial systems <\/td>\n<\/tr>\n
42<\/td>\n11.3.3 Loop systems
11.4 Medium or high voltage transformers
11.4.1 Transformer types
11.4.2 Installation <\/td>\n<\/tr>\n
43<\/td>\n11.4.3 Protection
11.5 Medium or high voltage switchgear and stations
11.5.1 General
11.5.2 Switchgear specifications
11.6 Medium voltage cable <\/td>\n<\/tr>\n
44<\/td>\n11.7 Utility interface
12 Auxiliary power systems
13 Communications systems
13.1 General
13.2 Data sampling speed requirements <\/td>\n<\/tr>\n
45<\/td>\nAnnex A (informative)Inverter application considerations in PV power plants
A.1 General
A.2 Advantages and disadvantages of central inverters
A.3 Advantages and disadvantages of string inverters <\/td>\n<\/tr>\n
46<\/td>\nA.4 Issues affecting inverter size
A.4.1 PV array output
A.4.2 Inverter ratings
A.4.3 Inverter output control requirements
A.4.4 PV power to inverter power ratio (PVIR) <\/td>\n<\/tr>\n
48<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Ground-mounted photovoltaic power plants. Design guidelines and recommendations<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2018<\/td>\n50<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":418040,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-418030","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/418030","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/418040"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=418030"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=418030"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=418030"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}