{"id":419862,"date":"2024-10-20T06:27:59","date_gmt":"2024-10-20T06:27:59","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-62059-32-12012-2\/"},"modified":"2024-10-26T12:05:22","modified_gmt":"2024-10-26T12:05:22","slug":"bs-en-62059-32-12012-2","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-62059-32-12012-2\/","title":{"rendered":"BS EN 62059-32-1:2012"},"content":{"rendered":"

The stability of metrological characteristics is one important aspect of durability.<\/p>\n

This part of IEC 62059 specifies a method for testing the stability of metrological characteristics of electricity meters, by operating a test specimen at the upper limit of the specified operating range of temperature, voltage and current for an extended period.<\/p>\n

Functional performance other than the accuracy of energy measurement is out of the scope of this standard.<\/p>\n

Note, that from the results of this test, no conclusion can be drawn for the length of period during which the stability of the metrological characteristics will be maintained when the meter is operated under usual conditions.<\/p>\n

This International Standard is applicable to all types of electricity meters in the scope of IEC TC 13.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
7<\/td>\nEnglish
CONTENTS <\/td>\n<\/tr>\n
8<\/td>\nINTRODUCTION <\/td>\n<\/tr>\n
9<\/td>\n1 Scope
2 Normative references
3 Terms and definitions <\/td>\n<\/tr>\n
10<\/td>\n4 General
5 Initial measurements
6 Conditioning <\/td>\n<\/tr>\n
12<\/td>\n7 Intermediate measurements \u2013 verification of energy measurement and registration
7.1 General
7.2 Method A: Test method using a reference meter <\/td>\n<\/tr>\n
14<\/td>\n7.3 Method B: Test method using a stable load <\/td>\n<\/tr>\n
15<\/td>\n7.4 Final temperature ramp
8 Recovery
9 Final measurements and acceptance criteria <\/td>\n<\/tr>\n
16<\/td>\n10 Information to be given in the test report
Table 1 \u2013 Limits of change in percentage error at Imax <\/td>\n<\/tr>\n
17<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Electricity metering equipment. Dependability – Durability. Testing of the stability of metrological characteristics by applying elevated temperature<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2012<\/td>\n19<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":419872,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1276,2641],"product_tag":[],"class_list":{"0":"post-419862","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-91-140-50","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/419862","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/419872"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=419862"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=419862"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=419862"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}