{"id":420167,"date":"2024-10-20T06:29:44","date_gmt":"2024-10-20T06:29:44","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-62625-22016-3\/"},"modified":"2024-10-26T12:08:38","modified_gmt":"2024-10-26T12:08:38","slug":"bs-en-62625-22016-3","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-62625-22016-3\/","title":{"rendered":"BS EN 62625-2:2016"},"content":{"rendered":"
This part of IEC 62625 covers the standardized test methods for verifying the compliance of an On board Driving Data Recording System implementation with the requirements specified by IEC 62625-1.<\/p>\n
Furthermore, it covers the conformity testing criteria for designed and manufactured ODDRS. This part of IEC 62625 includes the list of the requirements specified by IEC 62625-1 and the relevant acceptance conditions for ODDRS at design review, type test and routine test phases. For the train level design review and train level test phases, this part provides guidelines for the conformity testing methods to be applied to the ODDRS installed on the train.<\/p>\n
This part does not cover the conformity assessment schemes that, according to ISO\/IEC Directives Part 2, are the responsibility of ISO policy committee \u201cCommittee on conformity assessment\u201d (ISO\/CASCO). Consequently, this part does not include elements related to conformity assessment aspects other than design review and testing provisions for the products, processes or services which implements the requirements specified in IEC 62625-1. This part does not delete, change or interpret the general requirements for conformity assessment procedures and vocabulary detailed in ISO\/IEC 17000.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
4<\/td>\n | European foreword Endorsement notice <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | English CONTENTS <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 1 Scope 2 Normative references 3 Terms, definitions, abbreviations, acronyms, and conventions 3.1 Terms and definitions <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 3.2 Abbreviations and acronyms <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 4 Conformity testing 4.1 Overview 4.1.1 General 4.1.2 Applicability 4.1.3 Methodology <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | Figures Figure 1 \u2013 Conformity testing process <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 4.2 Implementation conformity statements 4.2.1 General 4.2.2 FICS and SICS 4.2.3 IXIT <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 5 Functional requirements conformity testing 5.1 Implementation statement for functional requirements conformity testing 5.1.1 General 5.1.2 Record train data 5.1.3 Ensure on board protection of recorded data Tables Table 1 \u2013 FICS pro-forma \u201cRecord train data\u201d <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 5.1.4 Ensure retrieval of recorded data 5.1.5 Recorded data analysis 5.1.6 List of provided optional functions Table 2 \u2013 FICS pro-forma \u201cEnsure on board protection of recorded data\u201d Table 3 \u2013 FICS pro-forma \u201cEnsure retrieval of recorded data\u201d Table 4 \u2013 FICS pro-forma \u201cRecorded data analysis\u201d Table 5 \u2013 FICS pro-forma \u201cList of provided optional functions\u201d <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 5.2 Standardized test methods for functional requirements <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Table 6 \u2013 Standardized test methods for functional requirements <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 6 System requirements conformity testing 6.1 Implementation statement for system requirements conformity testing 6.1.1 General 6.1.2 ODDRS mode 6.1.3 Recording \u00e8erformance 6.1.4 Environment 6.1.5 Availability and reliability Table 7 \u2013 SICS pro-forma \u201cODDRS mode\u201d Table 8 \u2013 SICS pro-forma \u201cRecording performance\u201d Table 9 \u2013 SICS pro-forma \u201cEnvironment\u201d <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 6.1.6 Security of records 6.1.7 Maintainability and diagnostic 6.1.8 Recorded data survivability 6.1.9 Recording resolution and frequency Table 10 \u2013 SICS pro-forma \u201cAvailability and reliability\u201d Table 11 \u2013 SICS pro-forma \u201cSecurity of records\u201d Table 12 \u2013 SICS pro-forma \u201cMaintainability and diagnostic\u201d Table 13 \u2013 SICS pro-forma \u201cRecorded data survivability\u201d <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 6.1.10 Time of day and date Table 14 \u2013 SICS pro-forma \u201cRecording resolution and frequency\u201d <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | 6.1.11 Train location 6.1.12 The unit of train speed 6.1.13 Input requirements Table 15 \u2013 SICS pro-forma \u201cTime of day and date\u201d Table 16 \u2013 SICS pro-forma \u201cTrain location\u201d Table 17 \u2013 SICS pro-forma \u201cThe unit of train speed\u201d <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | 6.1.14 Software identification and upgrading 6.1.15 Replacement time of ODDR unit 6.1.16 Power consumption 6.1.17 Data interface to subsystems and service interface Table 18 \u2013 SICS pro-forma \u201cInput requirements\u201d Table 19 \u2013 SICS pro-forma \u201cSoftware identification and upgrading\u201d Table 20 \u2013 SICS pro-forma \u201cReplacement time of ODDR unit\u201d Table 21 \u2013 SICS pro-forma \u201cPower consumption\u201d <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | 6.1.18 Optional mode switching time 6.2 Standardized test methods for system requirements Table 22 \u2013 SICS pro-forma \u201cData interface to subsystems and service interface\u201d Table 23 \u2013 SICS pro-forma \u201cOptional mode switching time\u201d <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | Table 24 \u2013 Standardized test methods for system requirements <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | 7 Arrangements for ODDR Unit type test 7.1 Type test with the integrated ODDRS 7.1.1 General 7.1.2 Equivalent signal generator, power supply <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | 7.1.3 Setup of the test environment Figure 2 \u2013 Test configurations at the integrated type test <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | Annex A (informative) FICS and SICS structure and instruction A.1 FICS and SICS pro-forma A.1.1 General A.1.2 Abbreviations used in FICS and SICS tables A.2 FICS and SICS tables A.2.1 Identification of FICS and SICS A.2.2 Identification of the implementation under test Table A.1\u00a0\u2013 FICS and SICS identification table <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | A.2.3 Identification of the IUT supplier A.2.4 Identification of the standards Table A.2\u00a0\u2013 IUT identification table Table A.3\u00a0\u2013 IUT supplier identification table Table A.4\u00a0\u2013 Applicable standards identification table <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | A.2.5 Global statement of conformity A.2.6 Level of conformity A.2.7 FICS and SICS tables structure Table A.5\u00a0\u2013 Global statement table <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | Table A.6\u00a0\u2013 FICS and SICS tables format <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | Annex B (informative) Methods for testing the parameter values of the protection capability B.1 Overview B.2 General procedure B.3 Detailed procedure B.3.1 Protection capability code FA <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | B.3.2 Protection capability code FB B.3.3 Protection capability code SA <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | B.3.4 Protection capability code SB B.3.5 Protection capability code PA B.3.6 Protection capability code CA Figure B.1 \u2013 Impact shock waveform <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | B.3.7 Protection capability code CB B.3.8 Protection capability code IA B.3.9 Protection capability code IB <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | B.3.10 Protection capability code HA B.3.11 Protection capability code MA <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Electronic railway equipment. On board driving data recording system – Conformity testing<\/b><\/p>\n |