{"id":423355,"date":"2024-10-20T06:46:03","date_gmt":"2024-10-20T06:46:03","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-620032020\/"},"modified":"2024-10-26T12:41:52","modified_gmt":"2024-10-26T12:41:52","slug":"bs-en-iec-620032020","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-620032020\/","title":{"rendered":"BS EN IEC 62003:2020"},"content":{"rendered":"

This document establishes requirements for electromagnetic compatibility testing of instrumentation, control, and electrical equipment supplied for use in systems important to safety at nuclear power plants and other nuclear facilities. The document lists the applicable IEC standards (principally the IEC 61000 series) which define the general test methods, and provides the necessary application-specific parameters and criteria to ensure that nuclear safety requirements are met.<\/p>\n

The normative part of this document is limited to the testing of equipment prior to installation in a nuclear power plant to demonstrate immunity to electromagnetic disturbances and to demonstrate that the equipment does not generate excessive emissions. Testing for the generation of excessive emissions is also applicable to non-safety equipment. This document includes informative annexes which provide additional guidance and describes approaches to maintaining electromagnetic compatibility for installed equipment. The intent of this document is to provide guidance for conducting the electromagnetic compatibility (EMC) qualification testing of the equipment and does not provide guidance for the installation of the equipment to prevent electromagnetic and radio frequency interference (EMI\/RFI). However, the configuration of the equipment under test during EMC qualification testing is representative of the intended installation in a nuclear facility.<\/p>\n

Protection against a high altitude electromagnetic pulse (HEMP) and intentional electromagnetic interference (IEMI) are outside of the scope of this document, but information can be found in IEC 61000-4-23, IEC 61000-4-24, and IEC 61000-4-25 (HEMP) and IEC 61000-4-36 (IEMI) to address these phenomena.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nundefined <\/td>\n<\/tr>\n
5<\/td>\nAnnex ZA(normative)Normative references to international publicationswith their corresponding European publications <\/td>\n<\/tr>\n
7<\/td>\nEnglish
CONTENTS <\/td>\n<\/tr>\n
9<\/td>\nFOREWORD <\/td>\n<\/tr>\n
11<\/td>\nINTRODUCTION <\/td>\n<\/tr>\n
13<\/td>\n1 Scope
2 Normative references <\/td>\n<\/tr>\n
15<\/td>\n3 Terms and definitions <\/td>\n<\/tr>\n
16<\/td>\n4 Abbreviated terms
Figures
Figure 1 \u2013 Examples of ports <\/td>\n<\/tr>\n
17<\/td>\n5 EMC test requirements <\/td>\n<\/tr>\n
18<\/td>\n6 Electromagnetic environment
Tables
Table 1 \u2013 Description of applicable EMC immunity and emissions tests for nuclear I&C and electrical equipment important to safety <\/td>\n<\/tr>\n
19<\/td>\nFigure 2 \u2013 Example of the situation of a power station <\/td>\n<\/tr>\n
20<\/td>\n7 Immunity testing
7.1 General
7.2 Applicability
7.3 Measurement uncertainty <\/td>\n<\/tr>\n
21<\/td>\n7.4 Test requirements
Table 2 \u2013 Immunity specifications \u2013 Enclosure port <\/td>\n<\/tr>\n
22<\/td>\nTable 3 \u2013 Immunity specifications \u2013 Signal and control ports <\/td>\n<\/tr>\n
23<\/td>\nTable 4 \u2013 Immunity specifications \u2013 Low voltage AC input and output power ports <\/td>\n<\/tr>\n
24<\/td>\n7.5 Immunity test considerations for wireless technology
Table 5 \u2013 Immunity specifications \u2013 Low voltage DC input and output power ports <\/td>\n<\/tr>\n
25<\/td>\n8 Emissions testing
Table 6 \u2013 Limits for radiated emissions from nuclear I&C and electrical equipment <\/td>\n<\/tr>\n
26<\/td>\n9 Test considerations
Table 7 \u2013 Limits for conducted emissions from nuclear I&C and electrical equipment <\/td>\n<\/tr>\n
27<\/td>\n10 Test report documentation <\/td>\n<\/tr>\n
28<\/td>\nAnnexes
Annex A (normative) Functional quality criteria of nuclear I&C and electrical EUT for immunity
Table A.1 \u2013 Functional quality criteria of nuclear I&C and electrical EUT for immunity <\/td>\n<\/tr>\n
29<\/td>\nAnnex B (informative) Quality characteristics defining the classification of electromagnetic environment severity in the locations where nuclear I&C and electrical power equipment is to be installed
Table B.1 \u2013 Quality characteristics defining the classification of electromagnetic environment severity in the locations where nuclear I&C and electrical equipment is to be installed <\/td>\n<\/tr>\n
32<\/td>\nAnnex C (informative) Explanation for the degrees of severity of tests for EMC immunity <\/td>\n<\/tr>\n
37<\/td>\nAnnex D (informative) Guidance for tests and evaluation of the electromagnetic environment in a nuclear power plant <\/td>\n<\/tr>\n
38<\/td>\nAnnex E (informative) Guidance for tests and evaluation of conformance with the requirements for emissions and immunity of operating nuclear I&C and electrical equipment <\/td>\n<\/tr>\n
39<\/td>\nAnnex F (informative) Example form of test plan for nuclear I&C and electrical equipment tests for emissions and immunity <\/td>\n<\/tr>\n
40<\/td>\nAnnex G (informative) Example form of test report for nuclear I&C and electrical equipment tests for emissions and immunity <\/td>\n<\/tr>\n
41<\/td>\nAnnex H (informative) EMC testing of power electronics and adjustable speed drives
Table H.1 \u2013 IEC 61800-3 conducted emissions limits for category C3 power distribution system in the second (typical industrial) environment <\/td>\n<\/tr>\n
42<\/td>\nTable H.2 \u2013 IEC 61800-3 radiated emissions limits for category C3 power distribution system in the second (typical industrial) environment <\/td>\n<\/tr>\n
43<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Nuclear power plants. Instrumentation, control and electrical power systems. Requirements for electromagnetic compatibility testing<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2020<\/td>\n44<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":423365,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[463,2641],"product_tag":[],"class_list":{"0":"post-423355","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-27-120-20","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/423355","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/423365"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=423355"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=423355"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=423355"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}