{"id":431331,"date":"2024-10-20T07:27:38","date_gmt":"2024-10-20T07:27:38","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-23-30472671-dc\/"},"modified":"2024-10-26T14:11:01","modified_gmt":"2024-10-26T14:11:01","slug":"bsi-23-30472671-dc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-23-30472671-dc\/","title":{"rendered":"BSI 23\/30472671 DC"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
6<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 4 Identification 5 Environmental conditions <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 6 Information on transport, storage and installation 7 Classification of tests <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 7.1 Design tests 7.2 Type tests 7.3 Sample tests 7.4 Routine tests 8 General requirements for insulator test specimens <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 9 Design tests 9.1 General 9.2 Tests on interfaces and connections of end fittings 9.2.1 General 9.2.2 Test specimens <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 9.2.3 Reference voltage and temperature for verification tests 9.2.4 Reference disruptive-discharge dry power frequency test 9.2.5 Product specific pre-stressing 9.2.6 Water immersion pre-stressing 9.2.7 Verification tests 9.2.7.1 General 9.2.7.2 Visual examination 9.2.7.3 Steep-front impulse voltage test 9.2.7.3.1 Procedure <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 9.2.7.3.2 Acceptance criteria 9.2.7.4 Dry power frequency voltage tests 9.2.7.4.1 Procedure 9.2.7.4.2 Acceptance criteria <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 9.3 Tests on housing material 9.3.1 Hardness test 9.3.1.1 Procedure <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 9.3.1.2 Acceptance criteria 9.3.2 Accelerated weathering test 9.3.2.1 Procedure 9.3.2.2 Acceptance criteria 9.3.3 Tracking and erosion test \u2013 1 000 h salt fog a.c. voltage test 9.3.3.1 General 9.3.3.2 Test chamber 9.3.3.3 Fog generation 9.3.3.4 Fog calibration <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 9.3.3.5 Test specimens 9.3.3.6 Test voltage 9.3.3.7 Test conditions <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 9.3.3.8 Acceptance criteria 9.3.4 Flammability test 9.3.4.1 Procedure 9.3.4.2 Acceptance criteria <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 9.3.5 Hydrophobicity transfer test 9.3.5.1 Method A 9.3.5.1.1 Test specimens 9.3.5.1.2 Test Procedure 9.3.5.1.3 Acceptance criteria 9.3.5.2 Method B 9.3.5.2.1 Test specimens <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 9.3.5.2.2 Test Procedure 9.3.5.2.3 Acceptance criteria 9.4 Tests on core material 9.4.1 Porosity test (Dye penetration test) 9.4.1.1 Procedure <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 9.4.1.2 Acceptance criteria 9.4.2 Water diffusion test 9.4.2.1 Test specimen 9.4.2.2 Test procedure 9.4.2.3 Acceptance criteria <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 9.4.3 Stress corrosion test 9.5 Water diffusion test on core with housing 9.5.1 General 9.5.2 Test specimens 9.5.3 Test procedure 9.5.4 Acceptance criteria <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Annex A (informative) Explanation of the concept of classes for the design tests <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | Annex B (informative) Recommended Test Application <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | Annex C (informative) Test for AC\/DC application <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Annex D (informative) Difference between the tracking and erosion and accelerated ageing test on polymeric insulators <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Annex E (informative) Consideration of Electric field control <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" BS EN IEC 62217. Polymeric HV insulators for indoor and outdoor use. General definitions, test methods and acceptance criteria<\/b><\/p>\n |