{"id":454245,"date":"2024-10-20T09:34:26","date_gmt":"2024-10-20T09:34:26","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iso-242522022a112023\/"},"modified":"2024-10-26T17:46:29","modified_gmt":"2024-10-26T17:46:29","slug":"bs-en-iso-242522022a112023","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iso-242522022a112023\/","title":{"rendered":"BS EN ISO 24252:2022+A11:2023"},"content":{"rendered":"
This document applies for systems for biogas production by anaerobic digestion, biogas conditioning, biogas upgrading and biogas utilization from a safety, environmental, performance and functionality perspective, during the design, manufacturing, installation, construction, testing, commissioning, acceptance, operation, regular inspection and maintenance phases. The following topics are excluded from this document: \u2014 boilers, burners, furnaces and lighting in case these are not specifically applied for locally produced biogas; \u2014 gas fuelled engines for vehicles and ships; \u2014 the public gas grid; \u2014 specifications to determine biomethane quality; \u2014 transportation of compressed or liquefied biogas; \u2014 transportation of biomass or digestate; \u2014 assessment and determination whether biomass is sourced sustainably or not. An informative explanation of the scope is included in Annex A.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Blank Page <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | European foreword <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | Annex A (informative) A\u2013deviations <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Blank Page <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 4 Abbreviated terms 5 Guide for reading this document <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 6 Safety principles <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 7 Safety studies 7.1 General 7.2 Risk assessment and evaluation 7.2.1 Risk assessment construction, start-up and maintenance 7.2.2 HAZOP\/HAZID <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 7.3 Explosion protection document (EPD) 7.4 Environmental requirements <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 8 General design requirements 8.1 Materials and structures 8.1.1 General 8.1.2 Materials <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 8.1.3 Structures, weight and stability calculations 8.1.4 Use of used materials and equipment 8.2 Process system facilities 8.2.1 General 8.2.2 Gas-side part of the system <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 8.2.3 Cooling systems 8.3 Pressure protection <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 8.4 Safety distances <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 8.5 Electronic monitoring of the process 8.5.1 General 8.5.2 Monitoring of the process <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 8.6 Buildings and building services 8.6.1 General 8.6.2 Gas detection and electronic monitoring inside buildings <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 8.6.3 Ventilation <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 8.7 Noise protection 8.8 Odour prevention 8.9 Soil and surface water protection <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 8.10 Condensate and particle removal 8.11 Storage of hazardous substances 8.11.1 Storage hazardous substances in general 8.12 Facilities at power failure <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 8.13 Air pollution control devices for removal of superfluous biogas (flares, thermal oxidizers gas, etc.) <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 8.14 Unwanted venting and discharges of hazardous gases 8.15 Flame protection and mitigation 8.16 Fire-fighting and extinguishing <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 8.17 Earthing and lightning protection 8.18 Emergency routing 8.19 Anti-collision 8.20 Access control 8.21 Electrical, instrumentation and process control <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 9 Biogas pipelines for untreated biogas 9.1 General 9.2 Materials <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | 9.3 Civil design 9.4 Removal of moisture and contaminants 10 Technical specifications and requirements biogas production 10.1 General <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | 10.2 Biomass supply and storage 10.3 Desulphurization 10.4 Biogas buffer 10.5 Storage, removal and stabilizing digestate <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | 10.6 Specific attention points and requirements landfill sites 10.7 Specific requirements additional to Clause 8 10.7.1 Materials and structures <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | 10.7.2 Equipment, pipes, valves and other process system facilities 10.7.3 Pressure protection 10.7.4 Foam <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | 10.7.5 Safety distances 10.7.6 Electronic monitoring of the process 10.7.7 Buildings and building services 10.7.8 Noise protection 10.7.9 Soil and surface water protection <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 10.7.10 Condensate and particle removal 10.7.11 Storage of hazardous substances 10.7.12 Facilities at power failure 10.7.13 Air pollution control devices for removal of superfluous biogas (flares, thermal oxidizers gas etc.) 10.7.14 Venting 10.7.15 Flame protection and mitigation 10.7.16 Firefighting and extinguishing <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | 10.7.17 Earthing and lightning protection 10.7.18 Emergency routing 10.7.19 Anti-collision 10.7.20 Electrical, instrumentation & process control 11 Technical specifications and requirements biogas treatment, CHP, upgrading and liquefaction 11.1 General 11.2 Desulphurization <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | 11.3 Biogas upgrading and liquefaction 11.4 Process system facilities 11.4.1 General 11.4.2 Gas-side part of the system 11.4.3 Cooling systems <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | 11.5 Specific requirements additional to Clause 8 11.5.1 Materials and structures 11.5.2 Pressure protection 11.5.3 Safety distances 11.5.4 Electronic monitoring of the process 11.5.5 Buildings and building services 11.5.6 Noise protection 11.5.7 Soil protection <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | 11.5.8 Condensate and particle removal 11.5.9 Storage of hazardous substances <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | 11.5.10 Facilities at power failure 11.5.11 Air pollution control devices for removal of superfluous biogas (flares, thermal oxidizers gas etc.) 11.5.12 Venting 11.5.13 Flame protection and mitigation 11.5.14 Fire-fighting and extinguishing 11.5.15 Earthing and lightning protection 11.5.16 Emergency routing 11.5.17 Anti-collision 11.5.18 Electrical, instrumentation & process control <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | 12 Construction and testing 12.1 General 12.2 Construction 12.2.1 Safety during construction 12.2.2 Prefabrication 12.2.3 Construction on site 12.3 Testing and commissioning <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | 12.4 Start-up 12.5 Requirements for commissioning and start-up of specific systems 12.5.1 Biogas production systems 12.5.2 Biogas treatment, CHP, upgrading and liquefaction systems 13 Operations and maintenance 13.1 General <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | 13.2 Supplier of the biogas system 13.3 System owner <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | 13.4 Emergency plan <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | 13.5 Service technician 13.6 Requirements for commissioning and start-up of specific systems 13.6.1 Biogas production systems 13.6.2 Biogas treatment, CHP, upgrading and liquefaction systems <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | 13.7 Requirements for shut-down of biogas system <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | Annex A (informative) Explanation to the scope <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | Annex B (informative) Biogas characteristics, processes and classifications <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | Annex C (informative) Guidelines to prevent risks from gases and explosive atmospheres in buildings <\/td>\n<\/tr>\n | ||||||
64<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Biogas systems. Non-household and non-gasification<\/b><\/p>\n |