{"id":459895,"date":"2024-10-20T10:06:35","date_gmt":"2024-10-20T10:06:35","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-61784-5-82024\/"},"modified":"2024-10-26T18:40:33","modified_gmt":"2024-10-26T18:40:33","slug":"bs-en-iec-61784-5-82024","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-61784-5-82024\/","title":{"rendered":"BS EN IEC 61784-5-8:2024"},"content":{"rendered":"

IEC 61784-5-8:2024 is available as IEC 61784-5-8:2024 RLV<\/span> which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61784-5-8:2024 specifies the installation profiles for CPF 8 (CC-LinkTM[1]). The installation profiles are specified in the annexes. These annexes are read in conjunction with IEC 61918:2018, IEC 61918:2018\/AMD1:2022 and IEC 61918:2018\/AMD2:2024. [1] CC-Link\u2122, CC-Link\/LT\u2122 and CC?Link IE\u2122 are trade names of Mitsubishi Electric Co., control of trade name use is given to CCLink Partner Association. This information is given for the convenience of users of this document and does not constitute an endorsement by IEC of the trademark holder or any of its products. Compliance to this profile does not require use of the trade name. Use of the trade name requires permission of the trade name holder.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nundefined <\/td>\n<\/tr>\n
5<\/td>\nAnnex ZA (normative)Normative references to international publicationswith their corresponding European publications <\/td>\n<\/tr>\n
6<\/td>\nEnglish
CONTENTS <\/td>\n<\/tr>\n
11<\/td>\nFOREWORD <\/td>\n<\/tr>\n
13<\/td>\nINTRODUCTION
Figures
Figure 1 \u2013 Standards relationships <\/td>\n<\/tr>\n
14<\/td>\n1 Scope
2 Normative references
3 Terms, definitions and abbreviated terms <\/td>\n<\/tr>\n
15<\/td>\n4 CPF 8: Overview of installation profiles
5 Installation profile conventions <\/td>\n<\/tr>\n
16<\/td>\n6 Conformance to installation profiles <\/td>\n<\/tr>\n
17<\/td>\nAnnex A (normative) CP 8\/1 and CP 8\/2 (CC-Link\u2122\/V1 and CC-Link\u2122\/V2) specific installation profile
A.1 Installation profile scope
A.2 Normative references
A.3 Installation profile terms, definitions, and abbreviated terms
A.3.1 Terms and definitions
A.3.2 Abbreviated terms
A.3.3 Conventions for installation profiles
A.4 Installation planning
A.4.1 General <\/td>\n<\/tr>\n
18<\/td>\nA.4.2 Planning requirements
A.4.3 Network capabilities <\/td>\n<\/tr>\n
19<\/td>\nFigure A.1 \u2013 Pass-through connector configuration
Figure A.2 \u2013 Bus t-branch topology <\/td>\n<\/tr>\n
20<\/td>\nA.4.4 Selection and use of cabling components
Tables
Table A.1 \u2013 Basic network characteristics for balanced cabling not based on Ethernet
Table A.2 \u2013 Bus t-branch network characteristics <\/td>\n<\/tr>\n
21<\/td>\nTable A.3 \u2013 Information relevant to copper cable: fixed cables <\/td>\n<\/tr>\n
22<\/td>\nFigure A.3 \u2013 Wiring
Table A.4 \u2013 Connectors for copper cabling CPs not based on Ethernet <\/td>\n<\/tr>\n
25<\/td>\nA.4.5 Cabling planning documentation
A.4.6 Verification of cabling planning specification
A.5 Installation implementation
A.5.1 General requirements <\/td>\n<\/tr>\n
26<\/td>\nA.5.2 Cable installation
Table A.5 \u2013 Parameters for balanced cables <\/td>\n<\/tr>\n
27<\/td>\nA.5.3 Connector installation
A.5.4 Terminator installation
Table A.6 \u2013 Cable conductor assignments <\/td>\n<\/tr>\n
28<\/td>\nA.5.5 Device installation
A.5.6 Coding and labelling
A.5.7 Earthing and bonding of equipment and devices and shield cabling
A.5.8 As-implemented cabling documentation <\/td>\n<\/tr>\n
29<\/td>\nA.6 Installation verification and installation acceptance test
A.6.1 General
A.6.2 Installation verification <\/td>\n<\/tr>\n
30<\/td>\nA.6.3 Installation acceptance test
A.7 Installation administration
A.8 Installation maintenance and installation troubleshooting <\/td>\n<\/tr>\n
31<\/td>\nAnnex B (normative) CP 8\/3 (CC-Link\/LT\u2122) specific installation profile
B.1 Installation profile scope
B.2 Normative references
B.3 Installation profile terms, definitions, and abbreviated terms
B.3.1 Terms and definitions
B.3.2 Abbreviated terms
B.3.3 Conventions for installation profiles
B.4 Installation planning
B.4.1 General <\/td>\n<\/tr>\n
32<\/td>\nB.4.2 Planning requirements
B.4.3 Network capabilities <\/td>\n<\/tr>\n
33<\/td>\nFigure B.1 \u2013 Powered network topology
Figure B.2 \u2013 Bus t-branch topology <\/td>\n<\/tr>\n
34<\/td>\nTable B.1 \u2013 Basic network characteristics for balanced cabling not based on Ethernet
Table B.2 \u2013 CP 8\/3 additional topology length limits <\/td>\n<\/tr>\n
35<\/td>\nB.4.4 Selection and use of cabling components
Figure B.3 \u2013 Flat cable cross section \u2013 with key
Figure B.4 \u2013 Flat cable cross section \u2013 without key <\/td>\n<\/tr>\n
36<\/td>\nFigure B.5 \u2013 Flat cable polarity marking
Table B.3 \u2013 Information relevant to copper cable: cords <\/td>\n<\/tr>\n
37<\/td>\nFigure B.6 \u2013 Wiring <\/td>\n<\/tr>\n
38<\/td>\nFigure B.7 \u2013 Flat cable connector and terminal cover <\/td>\n<\/tr>\n
39<\/td>\nTable B.4 \u2013 Connectors for copper cabling CPs not based on Ethernet <\/td>\n<\/tr>\n
42<\/td>\nB.4.5 Cabling planning documentation
B.4.6 Verification of cabling planning specification
B.5 Installation implementation
B.5.1 General requirements
B.5.2 Cable installation
Table B.5 \u2013 Parameters for balanced cables <\/td>\n<\/tr>\n
43<\/td>\nB.5.3 Connector installation
Table B.6 \u2013 Flat cable conductor assignments <\/td>\n<\/tr>\n
44<\/td>\nB.5.4 Terminator installation
B.5.5 Device installation
B.5.6 Coding and labelling
B.5.7 Earthing and bonding of equipment and devices and shield cabling
B.5.8 As-implemented cabling documentation <\/td>\n<\/tr>\n
45<\/td>\nB.6 Installation verification and installation acceptance test
B.6.1 General
B.6.2 Installation verification <\/td>\n<\/tr>\n
46<\/td>\nB.6.3 Installation acceptance test
B.7 Installation administration
B.8 Installation maintenance and installation troubleshooting <\/td>\n<\/tr>\n
47<\/td>\nAnnex C (normative) CP 8\/4 (CC-Link IE\u2122 Controller Network) specific installation profile
C.1 Installation profile scope
C.2 Normative references
C.3 Installation profile terms, definitions, and abbreviated terms
C.3.1 Terms and definitions
C.3.2 Abbreviated terms
C.3.3 Conventions for installation profiles
C.4 Installation planning
C.4.1 General
C.4.2 Planning requirements <\/td>\n<\/tr>\n
48<\/td>\nC.4.3 Network capabilities <\/td>\n<\/tr>\n
49<\/td>\nC.4.4 Selection and use of cabling components
Table C.1 \u2013 Network characteristics for balanced cabling based on Ethernet
Table C.2 \u2013 Network characteristics for optical fibre cabling <\/td>\n<\/tr>\n
50<\/td>\nTable C.3 \u2013 Information relevant to copper cable: fixed cables <\/td>\n<\/tr>\n
51<\/td>\nTable C.4 \u2013 Information relevant to optical fibre cables
Table C.5 \u2013 Connectors for balanced cabling CPs based on Ethernet <\/td>\n<\/tr>\n
52<\/td>\nTable C.6 \u2013 Optical fibre connecting hardware
Table C.7 \u2013 Relationship between FOC and fibre types (CP 8\/4) <\/td>\n<\/tr>\n
55<\/td>\nC.4.5 Cabling planning documentation
C.4.6 Verification of cabling planning specification
C.5 Installation implementation
C.5.1 General requirements <\/td>\n<\/tr>\n
56<\/td>\nC.5.2 Cable installation
Table C.8 \u2013 Parameters for balanced cables
Table C.9 \u2013 Parameters for silica optical fibre cables <\/td>\n<\/tr>\n
57<\/td>\nC.5.3 Connector installation
C.5.4 Terminator installation <\/td>\n<\/tr>\n
58<\/td>\nC.5.5 Device installation
C.5.6 Coding and labelling
C.5.7 Earthing and bonding of equipment and devices and shield cabling <\/td>\n<\/tr>\n
59<\/td>\nC.5.8 As-implemented cabling documentation
C.6 Installation verification and installation acceptance test
C.6.1 General
C.6.2 Installation verification <\/td>\n<\/tr>\n
60<\/td>\nC.6.3 Installation acceptance test
C.7 Installation administration
C.8 Installation maintenance and installation troubleshooting <\/td>\n<\/tr>\n
61<\/td>\nAnnex D (normative) CP 8\/5 (CC-Link IE\u2122 Field Network) specific installation profile
D.1 Installation profile scope
D.2 Normative references
D.3 Installation profile terms, definitions, and abbreviated terms
D.3.1 Terms and definitions
D.3.2 Abbreviated terms
D.3.3 Conventions for installation profiles
D.4 Installation planning
D.4.1 General
D.4.2 Planning requirements <\/td>\n<\/tr>\n
62<\/td>\nD.4.3 Network capabilities <\/td>\n<\/tr>\n
63<\/td>\nD.4.4 Selection and use of cabling components
Table D.1 \u2013 Network characteristics for balanced cabling based on Ethernet <\/td>\n<\/tr>\n
64<\/td>\nTable D.2 \u2013 Information relevant to copper cable: fixed cables <\/td>\n<\/tr>\n
65<\/td>\nTable D.3 \u2013 Connectors for balanced cabling CPs based on Ethernet <\/td>\n<\/tr>\n
68<\/td>\nD.4.5 Cabling planning documentation
D.4.6 Verification of cabling planning specification
D.5 Installation implementation
D.5.1 General requirements
D.5.2 Cable installation <\/td>\n<\/tr>\n
69<\/td>\nTable D.4 \u2013 Parameters for balanced cables <\/td>\n<\/tr>\n
70<\/td>\nD.5.3 Connector installation
D.5.4 Terminator installation
D.5.5 Device installation
D.5.6 Coding and labelling
D.5.7 Earthing and bonding of equipment and devices and shield cabling <\/td>\n<\/tr>\n
71<\/td>\nD.5.8 As-implemented cabling documentation
D.6 Installation verification and installation acceptance test
D.6.1 General
D.6.2 Installation verification <\/td>\n<\/tr>\n
72<\/td>\nD.6.3 Installation acceptance test <\/td>\n<\/tr>\n
73<\/td>\nD.7 Installation administration
D.8 Installation maintenance and installation troubleshooting <\/td>\n<\/tr>\n
74<\/td>\nAnnex E (normative) CP 8\/6 (CC-Link IE\u2122 TSN) specific installation profile
E.1 Installation profile scope
E.2 Normative references
E.3 Installation profile terms, definitions, and abbreviated terms
E.3.1 Terms and definitions
E.3.2 Abbreviated terms
E.3.3 Conventions for installation profiles
E.4 Installation planning
E.4.1 General <\/td>\n<\/tr>\n
75<\/td>\nE.4.2 Planning requirements
E.4.3 Network capabilities <\/td>\n<\/tr>\n
76<\/td>\nTable E.1 \u2013 Network characteristics for balanced cabling based on Ethernet <\/td>\n<\/tr>\n
77<\/td>\nE.4.4 Selection and use of cabling components
Table E.2 \u2013 Network characteristics for optical fibre cabling <\/td>\n<\/tr>\n
78<\/td>\nTable E.3 \u2013 Information relevant to copper cable: fixed cables <\/td>\n<\/tr>\n
79<\/td>\nTable E.4 \u2013 Information relevant to optical fibre cables <\/td>\n<\/tr>\n
80<\/td>\nTable E.5 \u2013 Connectors for balanced cabling CPs based on Ethernet
Table E.6 \u2013 Optical fibre connecting hardware
Table E.7 \u2013 Relationship between FOC and fibre types (CP 8\/6) <\/td>\n<\/tr>\n
83<\/td>\nE.4.5 Cabling planning documentation
E.4.6 Verification of cabling planning specification <\/td>\n<\/tr>\n
84<\/td>\nE.5 Installation implementation
E.5.1 General requirements
E.5.2 Cable installation
Table E.8 \u2013 Parameters for balanced cables
Table E.9 \u2013 Parameters for silica optical fibre cables <\/td>\n<\/tr>\n
85<\/td>\nE.5.3 Connector installation <\/td>\n<\/tr>\n
86<\/td>\nE.5.4 Terminator installation
E.5.5 Device installation
E.5.6 Coding and labelling
E.5.7 Earthing and bonding of equipment and devices and shield cabling <\/td>\n<\/tr>\n
87<\/td>\nE.5.8 As-implemented cabling documentation
E.6 Installation verification and installation acceptance test
E.6.1 General
E.6.2 Installation verification <\/td>\n<\/tr>\n
88<\/td>\nE.6.3 Installation acceptance test
E.7 Installation administration
E.8 Installation maintenance and installation troubleshooting <\/td>\n<\/tr>\n
89<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Industrial networks. Profiles – Installation of fieldbuses. Installation profiles for CPF 8<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2024<\/td>\n90<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":459905,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[385,2641],"product_tag":[],"class_list":{"0":"post-459895","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-25-040-40","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/459895","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/459905"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=459895"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=459895"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=459895"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}