{"id":463301,"date":"2024-10-20T10:27:51","date_gmt":"2024-10-20T10:27:51","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-2845-2023-6\/"},"modified":"2024-10-26T19:21:26","modified_gmt":"2024-10-26T19:21:26","slug":"ieee-2845-2023-6","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-2845-2023-6\/","title":{"rendered":"IEEE 2845-2023"},"content":{"rendered":"
New IEEE Standard – Active. This standard is applicable to celebratory balloons that are comparable in size and shape to what are commonly referred to as foil balloons and are available in retail stores and filled with helium or a lighter-than-air gas. The dielectric performance of celebratory balloons in contact with simulated energized overhead distribution power lines with the intent of minimizing balloon-caused power system outages (or electrical faults) are evaluated by the test procedures. The scope is limited to distribution system voltages of 38 kV or less and only single balloons. The effects of having any moisture, contaminants, or string or ribbon attachments to the balloon(s) are not investigated under this procedure.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | IEEE Std 2845\u2122-2023 Front cover <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | Title page <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Important Notices and Disclaimers Concerning IEEE Standards Documents <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Participants <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | Contents <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 1.\u2002Overview 1.1\u2002Scope 1.2\u2002Purpose <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 1.3\u2002Word usage 2.\u2002Normative references 3.\u2002Definitions, acronyms, and abbreviations 3.1\u2002Definitions 3.2\u2002Acronyms and abbreviations <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 4.\u2002Introduction <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 5.\u2002Safety awareness 5.1\u2002General 5.2\u2002High-voltage warning 5.3\u2002Ozone caution <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 6.\u2002Testing apparatus 6.1\u2002High-voltage source 6.2\u2002Voltage measurement 6.3\u2002Test conductor and configuration <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 6.4\u2002Ancillary positioning device <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 6.5\u2002Duration timing device 7.\u2002Prevailing conditions for testing <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 8.\u2002Test specimen 8.1\u2002General 8.2\u2002Balloon envelope <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 8.3\u2002Lighter-than-air gas 8.4\u2002Test specimen preparation <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 9.\u2002Sampling 9.1\u2002General 9.2\u2002Balloon envelope characteristics 9.3\u2002Number of test specimens in the sample <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 9.4\u2002Unacceptable sample 10.\u2002Test procedure 10.1\u2002General <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 10.2\u2002Determine test specimen dimension 10.3\u2002Maximum applicable voltage class 10.4\u2002Minimum applicable voltage class 10.5\u2002Testing <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 11.\u2002Acceptance criteria 11.1\u2002General <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 11.2\u2002Pass or fail 12.\u2002Marking and reporting 12.1\u2002Balloon marking <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 12.2\u2002Reporting <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | Annex\u00a0A (informative) The need for a testing methodology A.1\u2002General <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | Annex\u00a0B (informative) Development of spacing and withstand voltage B.1\u2002General <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | B.2\u2002Helium gas mix dielectric strength comparison <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | Annex\u00a0C (informative) Example of Class B balloon type for electrical testing C.1\u2002General <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | C.2\u2002Identification of the sample C.3\u2002Test specimen dimensional length C.4\u2002Maximum applicable voltage class C.5\u2002Minimum applicable voltage class <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | C.6\u2002Testing apparatus configuration <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | C.7\u2002The test sample C.8\u2002Hypothetical test results <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | Annex\u00a0D (informative) Bibliography <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | Back cover <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" IEEE Trial-Use Standard for Testing and Evaluating the Dielectric Performance of Celebratory Balloons in Contact with Overhead Power Distribution Lines Rated up to 38 kV System Voltage (Published)<\/b><\/p>\n |