{"id":72590,"date":"2024-10-17T16:20:53","date_gmt":"2024-10-17T16:20:53","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-d893-2011\/"},"modified":"2024-10-24T19:07:19","modified_gmt":"2024-10-24T19:07:19","slug":"astm-d893-2011","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-d893-2011\/","title":{"rendered":"ASTM-D893 2011"},"content":{"rendered":"<\/p>\n

1.1 This test method covers the determination of pentane and toluene insolubles in used lubricating oils.<\/p>\n

1.2 Procedure A<\/span><\/span> covers the determination of insolubles without the use of coagulant in the pentane. It provides an indication of the materials that can readily be separated from the oil-solvent mixtures by centrifuging.<\/p>\n

1.3 Procedure B<\/span><\/span> covers the determination of insolubles in oils containing detergents and employs a coagulant for both the pentane and toluene insolubles. In addition to the materials separated by using Procedure A, this coagulation procedure separates some finely divided materials that may be suspended in the oil.<\/p>\n

Note<\/span> 1Results obtained by Procedures A and B should not be compared since they usually give different values. The same procedure should be employed when comparing values obtained periodically on an oil in use or when comparing results determined by two or more laboratories.<\/p>\n

1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.<\/p>\n

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see Section 7 and 9.1.1.<\/span><\/span><\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nScope
Referenced Documents
Terminology
Summary of Test Method <\/td>\n<\/tr>\n
2<\/td>\nSignificance and Use
Apparatus
FIG. 1
TABLE 1
TABLE 2 <\/td>\n<\/tr>\n
3<\/td>\nReagents and Solvents
Sampling
Procedure A for Pentane and Toluene Insolubles Without Coagulant <\/td>\n<\/tr>\n
4<\/td>\nProcedure B for Coagulated Pentane and Toluene Insolubles
Calculation
Report
Precision and Bias
Keywords <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

D893-11 Standard Test Method for Insolubles in Used Lubricating Oils<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASTM<\/b><\/a><\/td>\n2011<\/td>\n11<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":72591,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2637],"product_tag":[],"class_list":{"0":"post-72590","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-astm","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/72590","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/72591"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=72590"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=72590"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=72590"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}