{"id":75000,"date":"2024-10-17T17:00:40","date_gmt":"2024-10-17T17:00:40","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-c791-3\/"},"modified":"2024-10-24T19:18:34","modified_gmt":"2024-10-24T19:18:34","slug":"astm-c791-3","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-c791-3\/","title":{"rendered":"ASTM-C791"},"content":{"rendered":"<\/p>\n
1.1 These test methods cover procedures for the chemical, mass spectrometric, and spectrochemical analysis of nuclear-grade boron carbide powder and pellets to determine compliance with specifications.<\/p>\n
1.2 The analytical procedures appear in the following order:<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | Scope Referenced Documents Significance and Use Reagents Safety Precautions Sampling <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | Scope Summary of Test Method Interferences Apparatus Reagents Sampling and Sample Preparation Calibration Procedure <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Calculation ( ) Scope Summary of Method Interferences <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Apparatus Reagents Precautions Sampling and Sample Preparation Procedure <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | Titrimetric Determination of Boron <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | ICP OES <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Precision and Bias Scope Summary of Method Interferences Isotopic Composition by TIMS <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Isotopic Composition by ICP MS <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | Scope Summary of Method Interferences Apparatus Reagents Precautions Procedure <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Pyrohydrolysis as Sample Preparation Procedure for Isotipic Composition by ICP MS Scope Summary of Method <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | Interferences Apparatus Reagents Calibration of Titrator Procedure Calculation Precision and Accuracy Scope Summary of Method <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | Interferences Apparatus Reagents Calibration of Electrode Procedure Calculation Precision and Accuracy Preface <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | Scope Water by Constant-Voltage Coulometry <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | Weight Loss on Drying Method <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | DCArc OES Method <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | Wet Chemical Methods <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Scope Summary of Method Interferences <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | Apparatus Reagents Precautions Standardization of Titrant Blank Sample Preparation Procedure <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | Calculation Procedure Calculation Precision and Bias <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Determination of Soluble Boron by ICP OES Scope Summary of Method Interferences Apparatus <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Reagents Sample Preparation Calibration Procedure Calculation of Free Carbon Content <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Precision and Bias A1. Commercial Reference Materials REFERENCES <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | TABLE 1 <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | FIG. 1 FIG. 2 <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | FIG. 3 <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | FIG. 4 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" C791-12 Standard Test Methods for Chemical, Mass Spectrometric, and Spectrochemical Analysis of Nuclear-Grade Boron Carbide <\/b><\/p>\n |