ANSI/ASHRAE/ASHE Standard 170 offers guidance, regulation, and mandates to designers of health care facilities. The revised 2017 edition incorporates 12 addenda to the 2013 standard andincludes the following significant changes: Addition of adiabatic humidifiers as an acceptable type Addition of a new type of exam room with lower requirements for less-acute applications Clarification around the prohibition of controls to change pressure relationships between spaces Reduction in requirements for electroconvulsive therapy procedure rooms Reduction in requirements for laboratories when allowed by certain calculations Higher requirements for higher hazard exhaust airstreams Coordination of space temperature requirements in the Sterile Processing Department withother industry groups Clarification of the definition of the primary diffuser array in operating rooms The standard has also been reorganized into three sections: hospital spaces, outpatient spaces, and nursing home spaces. These changes were made to bring Standard 170 into alignment with the forthcoming 2018 FGI Guidelines.

PDF Catalog

PDF Pages PDF Title
1 ANSI/ASHRAE/ASHE Standard 170-2017
3 CONTENTS
4 1. PURPOSE
2. SCOPE
3. DEFINITIONS
6 4. COMPLIANCE
5. PLANNING
6. SYSTEMS AND EQUIPMENT
8 Table 6.4 Minimum Filter Efficiencies
9 Table 6.7.2 Supply Air Outlets
10 7. SPACE VENTILATION—HOSPITAL SPACES
11 Table 7.1 Design Parameters—Hospital Spaces (Continued)
17 8. SPACE VENTILATION—OUTPATIENT SPACES
19 Table 8.1 Design Parameters—Outpatient Spaces
25 9. SPACE VENTILATION—NURSING HOME SPACES
27 Table 9.1 Design Parameters—Nursing Home Spaces
32 10. PLANNING, CONSTRUCTION, AND SYSTEM STARTUP
33 11. NORMATIVE REFERENCES
34 INFORMATIVE APPENDIX A—OPERATIONS AND MAINTENANCE (O&M) PROCEDURES
A1. O&M in Health Care Facilities
A2. Special Maintenance for HVAC Units
A3. Air Intake Opening for Areaway
Figure A3 Provisions for areaways.
35 INFORMATIVE APPENDIX B—INFORMATIVE REFERENCES AND BIBLIOGRAPHY
36 INFORMATIVE APPENDIX C—ADDENDA DESCRIPTION INFORMATION
Table C-1 ANSI/ASHRAE Addenda to ANSI/ASHRAE Standard 170-2013