Shopping Cart

No products in the cart.

ASHRAE 32.2 03 RA07 2003

$21.13

ASHRAE Standard 32.2-2003 (RA 2007) Methods of Testing for Rating Pre-Mix and Post-Mix Beverage Dispensing Equipment (ANSI Approved)

Published By Publication Date Number of Pages
ASHRAE 2003 12
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
4 FOREWORD
FOREWORD
1. PURPOSE
1. PURPOSE
2. SCOPE
2. SCOPE
3. DEFINITIONS
3. DEFINITIONS
4. CLASSIFICATION
4. CLASSIFICATION
5. MEASUREMENTS
5. MEASUREMENTS
5.1 Temperature Measurement. Temperature shall be measured with a calibrated instrument accurate to ±1ËšF (±0.5ËšC), traceable to NIST, within one year of calibration.
5.1 Temperature Measurement. Temperature shall be measured with a calibrated instrument accurate to ±1ËšF (±0.5ËšC), traceable to NIST, within one year of calibration.
5 5.2 Electrical Measurement. Electrical energy input shall be measured with an integrating instrument with the smallest- scale di…
5.2 Electrical Measurement. Electrical energy input shall be measured with an integrating instrument with the smallest- scale di…
5.3 Time Measurement. Time shall be measured with instruments having an accuracy within ±0.1% of the interval measured.
5.3 Time Measurement. Time shall be measured with instruments having an accuracy within ±0.1% of the interval measured.
5.4 Flow Measurement. Flow shall be measured with a device that measures mass or volume within an accuracy of ±1% and a time measurement.
5.4 Flow Measurement. Flow shall be measured with a device that measures mass or volume within an accuracy of ±1% and a time measurement.
6. TEST CONDITIONS
6. TEST CONDITIONS
6.1 Standard Test Conditions. The test conditions specified in Table 1 shall be used to determine standard performance.
6.1 Standard Test Conditions. The test conditions specified in Table 1 shall be used to determine standard performance.
6.2 Voltage and Frequency. Tests shall be performed at the nameplate rated voltage ±2% and at the rated frequency ±1%.
6.2 Voltage and Frequency. Tests shall be performed at the nameplate rated voltage ±2% and at the rated frequency ±1%.
7. TEST PROCEDURE GENERAL REQUIREMENTS
7. TEST PROCEDURE GENERAL REQUIREMENTS
7.1 Installation. The dispenser shall be
7.1 Installation. The dispenser shall be
7.2 Circulation of Air. To restrict the circulation of air at the rear of the equipment, a vertical partition or wall shall be l…
7.2 Circulation of Air. To restrict the circulation of air at the rear of the equipment, a vertical partition or wall shall be l…
7.3 Measurement of Ambient Temperature. The ambient temperature shall be measured by a single sensor located 12 in. (300 mm) in …
7.3 Measurement of Ambient Temperature. The ambient temperature shall be measured by a single sensor located 12 in. (300 mm) in …
8. ENERGY CONSUMPTION TEST
8. ENERGY CONSUMPTION TEST
8.1 Purpose. The purpose of this test is to determine the daily energy consumption of a mechanically refrigerated dispenser operating on standby.
8.1 Purpose. The purpose of this test is to determine the daily energy consumption of a mechanically refrigerated dispenser operating on standby.
8.2 Procedure
8.2 Procedure
6 9. PRODUCT DELIVERY PERFORMANCE TESTS
9. PRODUCT DELIVERY PERFORMANCE TESTS
9.1 Pre-Mix, Water, and Syrup Temperature Control. Pre-mix, water, and syrup temperatures shall be maintained within ±1.0ËšF (±0.5ËšC) of the specified temperature.
9.1 Pre-Mix, Water, and Syrup Temperature Control. Pre-mix, water, and syrup temperatures shall be maintained within ±1.0ËšF (±0.5ËšC) of the specified temperature.
9.2 Standard Drink Temperature Measurement. Beverage temperature shall be recorded as the lowest temperature measured while stirring the beverage.
9.2 Standard Drink Temperature Measurement. Beverage temperature shall be recorded as the lowest temperature measured while stirring the beverage.
9.3 High Ambient Temperature Performance Tests
9.3 High Ambient Temperature Performance Tests
7 9.4 Room Temperature Performance Tests
9.4 Room Temperature Performance Tests
9.5 Very High Ambient Performance Tests
9.5 Very High Ambient Performance Tests
8 INFORMATIVE APPENDIX A
INFORMATIVE APPENDIX A
Reporting Forms for Equipment Tested Using ANSI/ASHRAE Standard 32.2-2003 (RA 2007)
Reporting Forms for Equipment Tested Using ANSI/ASHRAE Standard 32.2-2003 (RA 2007)