Scope
1.1 This practice covers the minimum requirements and procedures for field or prefabricated application of Class PB Exterior Insulation and Finish Systems (EIFS) and EIFS with Drainage. Class PB EIFS are systems applied over insulation board, in which the base coat ranges from not less than 1/16 in. (1.6 mm) to ¼ in. (6.4 mm) in dry thickness, depending upon the number of nonmetallic reinforcing mesh layers encapsulated in the base coat (see Specification E 2568). The base coat is then covered with a finish coat of varying thickness in a variety of textures and colors. EIFS with Drainage provides a mechanism to drain incidental moisture
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 The text of this practice references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as a requirement of the standard.
1.4 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Keywords
Class PB; coating; drainage; EIFS; exterior insulation and finish system ; water-resistive barrier; WRB; Class PB exterior insulation/finish system; EIFS (exterior insulation/finish systems); Installation–gypsum products; Insulation
ICS Code
ICS Number Code 91.100.99 (Other construction materials)
DOI: 10.1520/C1397-09
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Terminology |
2 | Significance and Use Delivery of Materials Inspection Rejection Certification Storage of Materials Environmental Conditions Assessment of Condition of Substrates to Receive Water-Resistive Barrier Coating (if applicable) or Exterior Insulation and Finish Systems or Both |
3 | Water-Resistive Barrier (WRB) Coating (When Specified) (See Test Methods ) |
4 | Drainage Means (If Applicable) Insulation Board Installation Adhesive and Mechanical Attachment Method Mechanical Attachment Method General Requirements |
5 | Aesthetic Reveals Reinforced Base Coat Application Finish Coat Application |
6 | Curing Time Between Application Steps Cleanup Keywords A1. GENERAL INFORMATION A1.1 A1.2 |
7 | A1.3 A1.4 A1.5 A1.6 A1.7 A1.8 |
8 | A1.9 A2. EVALUATION OF PAPER-FACED GYPSUM SHEATHING FOR SURFACE ACCEPTABILITY A2.1 A2.2 A2.3 A2.4 A2.5 A3. SEALANT SYSTEMS A3.1 A3.2 A3.3 A3.4 A3.5 |