ASTM-C698 2010
$58.50
C698-10 Standard Test Methods for Chemical, Mass Spectrometric, and Spectrochemical Analysis of Nuclear-Grade Mixed Oxides ((U, Pu)O2)
Published By | Publication Date | Number of Pages |
ASTM | 2010 | 28 |
1.1 These test methods cover procedures for the chemical, mass spectrometric, and spectrochemical analysis of nuclear-grade mixed oxides, (U, Pu)O 2 , powders and pellets to determine compliance with specifications.
1.2 The analytical procedures appear in the following order:
1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. (For specific safeguard and safety precaution statements, see Sections 11, 20, 64, and 112 and 102.6.1.)
7.1 This test method covers the determination of 5 to 100 ? g/g of nitride nitrogen in mixtures of plutonium and uranium oxides in either pellet or powder form.
15.1 This test method covers the determination of 10 to 200 ? g of residual carbon in nuclear grade mixed oxides, (U,Pu)O 2 .
27.1 This test method is applicable to the determination of 5 to 100 ? g/g of chlorine and 1 to 100 ? g/g of fluorine in 1-g samples of nuclear-grade mixed oxides, (U, Pu)O 2 .
35.1 This test method covers the determination of sulfur in the concentration range from 10 to 600 ? g/g for samples of nuclear-grade uranium and plutonium mixed oxides, (U, Pu)O 2 .
44.1 This test method covers the determination of moisture in nuclear-grade mixed oxides of uranium and plutonium (U,Pu)O 2 . Detection limits are as low as 10 ? g.
52.1 This test method covers the determination of rare earths in uranium-plutonium dioxide over the range from 10 to 200 ? g/g.
60.1 This test method covers the analysis of uranium-plutonium dioxide [(U, Pu)O 2 ] for the 25 elements in the ranges indicated in Table 1, using gallium oxides or sodium fluoride as the carrier. (See also Table 2.)
70.1 This test method covers the spark source spectrographic analysis of uranium and plutonium dioxide for impurity elements. Because of its extreme sensitivity, it may be the most practical test method for the determination of certain impurities whose concentration is below the detectable limits of other spectrographic methods.
77.1 This test method covers the measurement of volatiles other than water in reactor-grade mixed dioxide pellets. The lower limit of the test method using the described equipment and a sample of approximately 1 g is 0.01 cm 3 per gram of sample at STP conditions (23).
85.1 This test method covers the determination of 5 to 150 ? g of tungsten in 1-g samples of nuclear-grade uranium and plutonium mixed oxides (U, Pu)O 2 (24).
94.1 This test method covers the determination of dysprosium, europium, gadolinium, and samarium in mixed oxides of uranium and plutonium over the concentration range from 0.1 to 10 ? g/g of mixed oxide.
98.1 This test method covers the determination of the isotopic composition of uranium and plutonium in nuclear-grade mixed oxides ((U, Pu)O 2 ).
107.1 This test method covers the determination of the oxygen-to-metal atom ratio (O/M) in sintered mixed oxide pellets and powders.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents |
2 | Significance and Use Reagents Safety Precautions |
3 | Sampling and Dissolution Scope Summary of Test Method Apparatus Reagents Precautions Procedure FIG. 1 |
4 | Calculation Precision and Bias Scope Summary of Test Method FIG. 2 |
5 | Interferences Apparatus Reagents and Materials Safety Precautions Sampling and Preparation Preparation of Apparatus Calibration |
6 | Procedure Calculation Precision and Bias Scope Summary of Test Method Interferences Apparatus (See and ) FIG. 3 |
7 | Reagents Pyrohydrolysis Procedure Measurement of Chloride and Fluoride |
8 | Precision and Bias |
9 | Scope Summary of Test Method Interference Apparatus Reagents FIG. 4 |
10 | Calibration Procedure Calculation Precision and Bias Scope FIG. 5 |
11 | Summary of Test Method Apparatus Reagents Operation Standardization Calculation Precision and Bias Scope Summary of Test Method |
12 | Apparatus Reagents and Materials Calibration Procedure Calculation Precision and Bias Scope |
13 | Summary of Test Method Apparatus Reagents and Materials Safety Precautions Calibration Procedure TABLE 1 TABLE 2 |
14 | Measurement Calculation FIG. 6 TABLE 3 |
15 | Precision and Bias Scope Summary of Test Method Apparatus Reagents Procedure |
16 | Calculation Precision and Bias Scope Summary of Test Method |
17 | Interferences Apparatus Reagents Procedure FIG. 7 |
18 | Calculation FIG. 8 |
19 | Precision and Bias Scope Summary of Test Method Interference Apparatus Reagents Procedure |
20 | Sample Analysis Calculation Precision and Bias Scope Summary of Test Method |
21 | Interferences Procedure Scope Summary of the Test Method Interferences Apparatus Reagents |
22 | Calibration of the Mass Spectrometer Procedure |
24 | Calculation |
25 | Precision and Bias Scope Summary of Test Method |
26 | Interferences Apparatus Reagents Safety Precautions Procedure FIG. 9 |
27 | Calculation Precision and Bias REFERENCES |