ASTM-D2791:2001 Edition
$40.63
D2791-93(2001) Standard Test Methods for Continuous Determination of Sodium in Water
Published By | Publication Date | Number of Pages |
ASTM | 2001 | 10 |
ASTM D2791-93-Reapproved2001
Historical Standard: Standard Test Methods for Continuous Determination of Sodium in Water
ASTM D2791
Scope
1.1 These test methods cover the continuous determination of trace amounts of sodium in water using an ion-selective electrode and flame photometry. Two test methods are included:
1.2 Test Method A is based on continuous application of the sodium ion electrode as reported in the technical literature (1-3). It is generally applicable over the range of 0.05 to 10 000 µg/L.
1.3 Test Method B is based on the use of flame photometry. It is most applicable to measurements below 20 µg/L. Compared with Test Method A, it is less vulnerable to interference from other monovalent cations at low concentrations and can reach equilibrium with very low sample throughput.
1.4 The analyst should be aware that adequate collaborative data for precision and bias statements as required by Practice D2777 are not provided. See Sections 16 and 26 for details.
1.5 The values stated in SI units are to be regarded as standard. The inch-pound units given in parentheses are for information only.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements see Section 6.
Keywords
continuous sodium measurement; flame photometry; ion-selective electrode; specific ion
ICS Code
ICS Number Code 13.060.50 (Examination of water for chemical substances)
DOI: 10.1520/D2791-93R01
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Terminology Significance and Use Reagents and Materials |
2 | Hazards Sampling Scope Summary of Test Method Interferences |
3 | Apparatus Reagents and Materials Calibration and Standardization |
5 | Procedure Response Time Precision and Bias Scope Summary of Test Method Interferences |
6 | Apparatus Reagents and Materials Sampling Calibration and Standardization |
7 | Procedure |
8 | Calculation Precision and Bias Keywords A1. CONSTRUCTION OF pH ADJUSTMENT SYSTEMS FOR TEST METHOD A A1.1 Anhydrous Ammonia A1.2 Morpholine A1.3 Dimethylamine A1.4 Diisopropylamine A1.5 Ammonium Hydroxide or Monoethylamine Solution |
9 | A2. ELECTRODE RESPONSE IN TEST METHOD A A2.1 Faulty Electrode Response A2.2 Impaired Electrode Response A2.3 Electrode Cleaning Techniques A2.4 Temperature Compensation X1. SPECTROPHOTOMETER CHARACTERISTICS X1.1 X1.2 X1.3 |
10 | X1.4 REFERENCES |