Scope

1.1 These test methods cover the determination of ethylbenzene and total eight-carbon (C8) and heavier aromatics in the concentration range from 0.1 to 30 % in mineral spirits having a distillation range from 149 to 210Ā°C (300 to 410Ā°F) as determined by Test Method D 86. The procedures permit the identification and calculation of concentrations of aromatic components to 0.1 volume %.

1.2 It is recognized by analytical chemists that a single column gas chromatography analysis of an unknown sample is risky. In such cases, multiple and different analytical techniques must be used for absolutely positive identification, for example, several different gas chromatography columns, gas chromatography/mass spectrometer, or gas chromatography/infrared, etc. In these test methods the material is known and is clearly defined.

1.3 Oxygenated compounds, if present, may interfere and cause erroneous results. Such oxygenated compounds are not normally present in mineral spirits.

1.4 Three test methods are covered as follows:

1.4.1 Test Method A measurement of ethylbenzene content, C8 plus higher aromatics (except ethylbenzene), and total aromatics by means of a single packed column gas chromatographic analysis.

1.4.2 Test Method B measurement of ethylbenzene content by means of a rapid packed column gas chromatographic analysis.

1.4.3 Test Method C measurement of ethylbenzene content, C8 plus higher aromatics (except ethylbenzene) and total aromatics by means of a capillary column gas chromatographic analysis.

1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.6 For purposes of determining conformance of an observed or a calculated value using this test method to relevant specifications, test result(s) shall be rounded off “to the nearest unit” in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E 29.

1.7 For hazard information and guidance, see the supplier’s Material Safety Data Sheet.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

aromatics in mineral spirits; ethylbenzene in mineral spirits; gas chromatography (GC); mineral spirits

ICS Code

ICS Number Code 87.060.30 (Solvents)

DOI: 10.1520/D3257-06

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Summary of Test Methods
2 Significance and Use
FIG. 1
FIG. 2
FIG. 3
3 Apparatus
Reagents and Materials
Calibration
TABLE 1
TABLE 2
4 Procedure
Calculation
Report
Precision and Bias
5 Apparatus
Reagents and Materials
Procedure
Calculation
Report
Precision and Bias
6 Apparatus
Preparation of Apparatus
Calibration
TABLE 3
7 Calculation
Report
Precision and Bias
FIG. 4
8 Keywords