$44.96

D3859-08 Standard Test Methods for Selenium in Water

Published By Publication Date Number of Pages
ASTM 2008 11
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

1.1 These test methods cover the determination of dissolved and total recoverable selenium in most waters and wastewaters. Both test methods utilize atomic absorption procedures, as follows:

1.2 These test methods are applicable to both inorganic and organic forms of dissolved selenium. They are applicable also to particulate forms of the element, provided that they are solubilized in the appropriate acid digestion step. However, certain selenium-containing heavy metallic sediments may not undergo digestion.

1.3 These test methods are most applicable within the following ranges:

These ranges may be extended (with a corresponding loss in precision) by decreasing the sample size or diluting the original sample, but concentrations much greater than the upper limits are more conveniently determined by flame atomic absorption spectrometry.

1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see 11.12 and 13.14.

7.1 This test method covers the determination of dissolved and total recoverable selenium in the range from 1 to 20 ? g/L. The range may be extended by decreasing the sample size or diluting the original sample.

7.2 This test method has been used successfully with reagent water, natural water, wastewater, and brines. The information on precision may not apply to waters of other matrices.

17.1 This test method includes the determination of dissolved and total recoverable selenium in the range from 2 to 100 ? g/L. The range may be extended by decreasing the sample size or diluting the original sample.

17.2 This test method has been used successfully with reagent water, waste treatment plant effluent, tap water, well water, and treated wood plant effluent. The information on precision may not apply to waters of other matrices.

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
Significance and Use
2 Purity of Reagents
Sampling
Scope
Summary of Test Method
Interferences
Apparatus
3 FIG. 1
4 Reagents and Materials
Standardization
Procedure
5 Calculation
Precision and Bias
Quality Control
TABLE 1
6 TABLE 2
7 Scope
Summary of Test Method
Interferences
Apparatus
Reagents and Materials
8 Standardization
Procedure
9 Calculation
Precision and Bias
Quality Control
TABLE 3
10 Keywords
ASTM-D3859 2008
$44.96