ASTM-D3871:2011 Edition
$40.63
D3871-84(2011) Standard Test Method for Purgeable Organic Compounds in Water Using Headspace Sampling
Published By | Publication Date | Number of Pages |
ASTM | 2011 | 9 |
ASTM D3871-84-Reapproved2011
Historical Standard: Standard Test Method for Purgeable Organic Compounds in Water Using Headspace Sampling
ASTM D3871
Scope
1.1 This test method covers the determination of most purgeable organic compounds that boil below 200°C and are less than 2 % soluble in water. It covers the low μg/L to low mg/L concentration range (see Section 15 and Appendix X1).
1.2 This test method was developed for the analysis of drinking water. It is also applicable to many environmental and waste waters when validation, consisting of recovering known concentrations of compounds of interest added to representative matrices, is included.
1.3 Volatile organic compounds in water at concentrations above 1000 μg/L may be determined by direct aqueous injection in accordance with Practice D2908.
1.4 It is the user’s responsibility to assure the validity of the test method for untested matrices.
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in 8.5.5.1.
Keywords
drinking water; gas chromatography; purge and trap; volatile organic compounds; Dynamic headspace analysis; Organic compounds–water; Purgeable organic compounds; Sampling water analysis applications; Wastewater testing/treatment
ICS Code
ICS Number Code 13.060.50 (Examination of water for chemical substances)
DOI: 10.1520/D3871-84R11
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Terminology Summary of Test Method Significance and Use Interferences Apparatus |
2 | Reagents and Materials |
3 | Sampling Calibration and Standardization Conditioning Traps |
4 | Procedure Calculation Report Precision and Bias |
5 | Keywords TABLE 1 TABLE 2 |
6 | A1. LIST OF PARTS AND INSTRUCTIONS FOR ASSEMBLY OF PURGING DEVICE, TRAP, AND DESORBERS A1.1 Purging Device A1.2 Trap FIG. A1.1 FIG. A1.2 |
7 | A1.3 Desorbers FIG. A1.3 FIG. A1.4 |
8 | X1. SINGLE-OPERATOR PRECISION AND BIAS X1.1 TABLE X1.1 |
9 | REFERENCES TABLE X1.2 TABLE X1.3 |