D422-63(2002)e1 Standard Test Method for Particle-Size Analysis of Soils

Published By Publication Date Number of Pages
ASTM 2002 8
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

1.1 This test method covers the quantitative determination of the distribution of particle sizes in soils. The distribution of particle sizes larger than 75 ?m (retained on the No. 200 sieve) is determined by sieving, while the distribution of particle sizes smaller than 75 ?m is determined by a sedimentation process, using a hydrometer to secure the necessary data (Note 1 and Note 2).

Note 1Separation may be made on the No. 4 (4.75-mm), No. 40 (425-?m), or No. 200 (75-?m) sieve instead of the No. 10. For whatever sieve used, the size shall be indicated in the report.

Note 2Two types of dispersion devices are provided: ( 1 ) a high-speed mechanical stirrer, and ( 2 ) air dispersion. Extensive investigations indicate that air-dispersion devices produce a more positive dispersion of plastic soils below the 20-?m size and appreciably less degradation on all sizes when used with sandy soils. Because of the definite advantages favoring air dispersion, its use is recommended. The results from the two types of devices differ in magnitude, depending upon soil type, leading to marked differences in particle size distribution, especially for sizes finer than 20 ?m.

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Apparatus
2 Dispersing Agent
FIG. 1
FIG. 2
3 Test Sample
FIG. 3
FIG. 4
4 Procedure
Determination of Composite Correction for Hydrometer Reading
Hygroscopic Moisture
Dispersion of Soil Sample
5 Hydrometer Test
Sieve Analysis
Sieve Analysis Values for the Portion Coarser than the No. 10 (2.00-mm) Sieve
Hygroscopic Moisture Correction Factor
Percentages of Soil in Suspension
6 Diameter of Soil Particles
Sieve Analysis Values for Portion Finer than No. 10 (2.00-mm) Sieve
TABLE 1
7 Graph
Report
TABLE 2
8 Keywords
TABLE 3