ASTM-D5093 2015
$40.63
D5093-15 Standard Test Method for Field Measurement of Infiltration Rate Using Double-Ring Infiltrometer with Sealed-Inner Ring
Published By | Publication Date | Number of Pages |
ASTM | 2015 | 7 |
ASTM D5093-15
Historical Standard: Standard Test Method for Field Measurement of Infiltration Rate Using Double-Ring Infiltrometer with Sealed-Inner Ring
ASTM D5093
Scope
1.1 This test method describes a procedure for measuring the infiltration rate of water through in-place soils using a double-ring infiltrometer with a sealed inner ring.
1.2 This test method is useful for soils with infiltration rates in the range of 1āĆā10ā5 cm/s to 1āĆā10ā8 cm/s. When infiltration rates ā„1āĆā10ā5 cm/s are to be measured Test Method D3385 shall be used.
1.3 All observed and calculated values shall conform to the guide for significant digits and rounding established in Practice D6026.
1.3.1 The method used to specify how data are collected, calculated, or recorded in this standard is not directly related to the accuracy to which the data can be applied in design or other uses, or both. How one applies the results obtained using this standard is beyond its scope.
1.4 This test method provides a direct measurement of infiltration rate, not hydraulic conductivity. Although the units of infiltration rate and hydraulic conductivity are similar, there is a distinct difference between these two quantities. They cannot be directly related unless the hydraulic boundary conditions, such as hydraulic gradient and the extent of lateral flow of water are known or can be reliably estimated.
1.5 This test method can be used for natural soil deposits, recompacted soil layers, and amended soils such as soil bentonite and soil lime mixtures.
1.6 UnitsāThe values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units, which are provided for information only and are not considered standard.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Keywords
double ring infiltration; in-place infiltration; soil moisture infiltrometer ;