Shopping Cart

No products in the cart.

ASTM-D6793 2012

$40.63

D6793-02(2012) Standard Test Method for Determination of Isothermal Secant and Tangent Bulk Modulus

Published By Publication Date Number of Pages
ASTM 2012 5
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

ASTM D6793-02-Reapproved2012

Withdrawn Standard: Standard Test Method for Determination of Isothermal Secant and Tangent Bulk Modulus (Withdrawn 2021)

ASTM D6793

Scope

1.1 This test method covers the determination of isothermal secant and tangent bulk modulus of liquids which are stable and compatible with stainless steel under the conditions of test.

1.2 This test method is designed to be used over the temperature range from -40 to 200Ā°C and from ambient to 68.95 Mpa (10 000 psig).

Note 1ā€”Because of the design of the test apparatus, the upper limit of pressure which can be attained is limited by the bulk modulus of the test fluid. Pressures as high as 68.95 Mpa will not be attained for fluids of relatively low bulk modulus at the test temperature.

1.3 This test method assumes that the user is proficient in the assembly and use of medium pressure (m/p) threaded and coned fittings which are intended for use at pressures up to 137.9 Mpa (20 000 psig).

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Note 2ā€”Because hydraulic pressure in the test system is produced by purely mechanical means, the test method is not subject to the hazards associated with systems which are pressurized pneumatically. Even small leaks will result in immediate drop in pressure to ambient without production of a high pressure liquid stream or mist.

Keywords

density; dynamic bulk modulus; isentropic bulk modulus; isothermal bulk modulus; isothermal secant bulk modulus; isothermal tangent bulk modulus; pressure; static bulk modulus; Compressibility; Dynamic analysis/testing; Isentropic bulk modulus; Isothermal conditions/testing; Secant bulk modulus; Static bulk modulus; Tangent bulk modulus

ICS Code

ICS Number Code 75.160.20 (Liquid fuels)

DOI: 10.1520/D6793-02R12

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
Summary of Test Method
2 Significance and Use
Apparatus
Reagents and Materials
Sampling
Preparation of Apparatus
FIG. 1
3 Calibration
Procedure
Calculations
Report
Precision and Bias
Keywords
4 X1. ISOTHERMAL BULK MODULUS CALIBRATION
X1.1 Calibration Fluid
X1.2 Calibration Temperature
X1.3 Data from International Critical Tables
X1.4 Calibration
X2. DETERMINATION OF ISOTHERMAL SECANT BULK MODULUS
X2.1
X2.2 Test Specimen
X2.3 Test Temperature
X2.4 Calibration Fluid
X2.5 Calibration
TABLE X1.1
TABLE X2.1
ASTM-D6793 2012