Scope

1.1 These specifications cover the equipment making up the temporary grounding system used on de-energized electric power lines, electric supply stations, and equipment.

1.2 It is common practice for the users of protective grounding equipment to prepare complete instructions and regulations to govern in detail the correct use and maintenance of such equipment.

1.3 The uses and maintenance of this equipment are beyond the scope of these specifications.

1.4 These specifications for a system of protective grounding utilizing copper cables are covered in four parts, as follows:

1.5 Each of the four parts is an entity of itself, but is listed as a part of the system for completeness and clarification.

1.6 Currents presented in Table 1 are based upon cable melting times, as determined from equations by I. M. Onderdonk and are to used in situations involving an asymmetry value less than 20 % (X/R 1.8). See Appendix X3.

1.6.1 Currents presented in Table 2 are based upon the values from EPRI Project RP2446 Computer Program RTGC A Desktop Computer Program for Calculating Rating of Temporary Grounding Cables and are to be used in situations involving an asymmetry value greater then 20 % (X/R 1.8), see Appendix X4.

Note 1—Table 1 represents the clamp and assembly ratings that existed prior to this revision. Table 2 represents new ratings now required for high X/R situations.

1.6.2 See Appendix X3 and Appendix X4 for a discussion of these topics.

1.7 The values stated in Newton-Meter units are to be regarded as the standard. The values in parentheses are the inch-pound units.

1.8 The following precautionary caveat pertains to the test method portions, Sections 12 and 25 of these specifications: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

Current measurement; Electrical insulating materials–specifications; Electrical power systems–specifications; Electrical protective equipment–specifications; Grounding; Protective grounds; Temporary grounding systems

ICS Code

ICS Number Code 29.120.50 (Fuses and other overcurrent protection devices)

DOI: 10.1520/F0855-09

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
2 Terminology
TABLE 1
TABLE 2
3 Scope
Classification
Sizes
Ordering Information
Materials
Electrical and Mechanical Properties
4 Workmanship, Finish, and Appearance
Sampling
Design Tests
TABLE 3
5 Inspection and Product Testing
Acceptance, Rejection, and Rehearing
Certification
Packaging and Package Marking
Scope
FIG. 1
6 Classification
Size
Ordering Information
Materials
Electrical and Physical Properties
TABLE 4
7 Workmanship, Finish, and Appearance
Sampling
Design Tests
TABLE 5
8 Inspection
Acceptance, Rejection, and Rehearing
Certification
Product Marking
Packaging
Scope
Classification
Size
Ordering Information
TABLE 6
9 Materials
Workmanship, Finish, and Appearance
Sampling
Tests
Protective Cable Ratings
TABLE 7
10 Scope
Classification
FIG. 2
11 Sizes
Ordering Information
Materials
Electrical and Mechanical Properties
Workmanship, Finish, and Appearance
FIG. 3
FIG. 4
12 Sampling
FIG. 5
FIG. 6
FIG. 7
FIG. 8
13 Design Tests
Inspection and Production Testing
Acceptance, Rejection, and Rehearing
FIG. 9
14 Certification
Packaging and Package Marking
FIG. 10
15 X1. MANUFACTURE OF GROUNDING CABLE
X1.1
X1.2
X1.3
16 X2. COMMENTARY
X2.1
X2.2
X2.3
X3. DISCUSSION OF CABLE FUSING
X3.1
X3.2
X4. EFFECT OF ASYMMETRICAL CURRENTS ON TEMPORARY PROTECTIVE GROUNDING EQUIPMENT
X4.1
X4.2
17 X4.3
X4.4
X4.5
X4.6
X4.7
FIG. X4.1
18 X5. TESTING FOR MULTIPLE ASSEMBLIES
X5.1
X5.2
FIG. X4.2
ASTM-F855 2009
$44.96