Shopping Cart

No products in the cart.

BS 7870-4.13:2001

$142.49

LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV – Single core 33 kV copper wire/foil sheath cables – Section 4.13: Single core 33 kV copper wire/foil sheath cables

Published By Publication Date Number of Pages
BSI 2001 26
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
1 BRITISH STANDARD
2 Committees responsible for this British�Standard
3 Contents
5 1 Scope
2 Normative references
3 Voltage designation
4 Construction and dimensions
4.1 Conductors
6 4.2 Screens and insulation
4.3 Metallic screen
4.4 Water blocking tape
7 4.5 Copper foil sheath
4.6 Oversheath
4.7 Triplex cables
4.8 Marking
8 4.9 End sealing
4.10 Dimensions
Table 1
9 5 Tests
Table 2
10 6 Routine tests
6.1 Spark test
6.2 Conductor resistance
6.3 Copper wire/foil sheath resistance
Table 3
6.4 Voltage test
6.5 Partial discharge test
6.6 Cable markings
7 Sample tests
7.1 Conductor material and construction
7.2 Conductor screen
11 7.3 Insulation
7.4 Circularity of insulated core
7.5 Insulation screen
7.6 Irregularities of insulation and screen
7.7 Metallic screen
7.8 Water blocking tape
7.9 Copper foil sheath
12 7.10 Oversheath
7.11 Bending test/4�h voltage test
8 Type tests
8.1 Material tests
13 Table 4
14 Table 5
Table 6
15 8.2 Sequential electrical tests
Table 7
Table 8
16 8.3 Long term test
8.4 Short-circuit test
8.5 Earth fault spiking test
17 Annex A (informative)
Guidance on selection of single core copper foil sheath cables
Table A.1
Annex B (informative)
Guidance on type tests
General
Type tests on cables
18 Compatibility test
Type tests on components
Annex C (normative)
Water penetration test
Test piece
Test
19 Figure C.1 Water penetration test
20 Annex D (normative)
Peel strength of copper foil overlap
Figure D.1 Peel strength of copper foil overlap
21 Annex E (normative)
Sidewall pressure test
Figure E.1 Sidewall pressure test
Table E.1 Sidewall pressure
22 Annex F (normative)
Impact test
Figure F.1 Impact test
23 Annex G (normative)
Earth fault spiking test
Objective
Spiking test sample
Electrical circuit
Spiking procedure
Test procedure
24 Number of samples/tests
Examination
BS 7870-4.13:2001
$142.49