BS EN 1366-10:2022
$215.11
Fire resistance tests for service installations – Smoke control dampers
Published By | Publication Date | Number of Pages |
BSI | 2022 | 104 |
This document specifies test methods for smoke control dampers to assess their performance under elevated temperature or fire conditions, as well as at ambient temperatures. Smoke control damper tests are used to confirm that the furnace testing requirements of EN 12101-8 are met and EN 12101-8 is for consideration before carrying out these tests. Smoke control dampers tested to this document are expected to be classified using EN 13501-4 and this document is expected to be considered before carrying out these tests. NOTE Some smoke control dampers to be tested might require testing following the information given in EN 1366-2 and this needs consideration before carrying out testing. This document is expected to be read in conjunction with EN 12101-8, EN 13501-4, EN 1366-2 and EN 1363-1, the latter giving further details for fire resistance testing. For installation details, the requirements for smoke extraction ducts are for consideration and these are defined in EN 1366-8 and EN 1366-9.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
11 | 1 Scope 2 Normative references 3 Terms and definitions |
14 | 4 Test equipment 4.1 General 4.2 Test duct for surface mounted SCDs |
15 | 4.3 Connecting duct for compartment boundary mounted SCDs 4.3.1 Compartmentation test 4.3.2 Maintenance of opening test 4.4 Cycling equipment 4.5 Condensing unit 4.6 Gas temperature measuring devices 4.7 Exhaust fan system |
16 | 4.8 Perforated plate 4.9 Volume and flow measurement for duct mounted SCDs 4.10 Volume flow measurement for compartment boundary mounted SCDs 4.10.1 Compartmentation test 4.10.2 Maintenance of opening test |
17 | 4.11 Ambient leakage measurement equipment 4.12 Pressure sensors for differential pressure control 4.12.1 Duct mounted smoke control dampers 4.12.2 Compartment boundary mounted smoke control dampers 4.13 Welded connecting tube 4.14 Extract fan connecting duct 4.15 Extraction fan 4.16 Thermocouples 4.17 Oxygen measuring equipment |
18 | 4.18 Observation windows 5 Test specimens 5.1 Cross-section 5.2 Design 5.2.1 General 5.2.2 Supporting constructions 5.2.2.1 General 5.2.2.2 Duct for single compartment smoke control dampers 5.2.2.3 Duct for multi compartment smoke control dampers |
19 | 5.2.2.4 Smoke control dampers mounted in a compartment boundary 5.2.3 Inclusion of grilles 6 Test methods 6.1 General 6.2 Test sequence |
21 | 6.3 Ambient leakage 6.3.1 Units of the largest size 6.3.2 Units of smallest size 6.4 Cycling requirements 6.4.1 General 6.4.2 Smoke control damper to be used in dedicated smoke control systems, operated only in the case of emergency 6.4.3 Smoke control damper to be used as part of a general HVAC system as well as a smoke control system, or as part of a smoke control systems that is cycled every day to check operation |
22 | 6.4.4 Smoke control damper to be used as part of a general HVAC system as well as a smoke control system, that uses a modulating actuator 6.5 Selection of elevated temperature and fire resistance tests |
23 | 6.6 Fire resistance tests and elevated temperature tests 6.6.1 Duct mounted smoke control dampers 6.6.1.1 Mounting conditions |
24 | 6.6.1.2 Elevated temperature tests and fire resistance tests for duct mounted smoke control dampers (single and multi-compartment respectively) 6.6.1.3 Maintenance of opening for duct mounted smoke control dampers 6.6.2 Compartment boundary mounted smoke control dampers 6.6.2.1 Mounting conditions |
25 | 6.6.2.2 Fire resistance test for compartment boundary mounted smoke control dampers |
26 | 6.6.2.3 Maintenance of opening test for compartment boundary mounted smoke control dampers |
27 | 6.6.3 Additional test information 6.6.3.1 Smoke control dampers mounted on a duct 6.6.3.2 Smoke control dampers mounted in a compartment boundary |
28 | 6.7 Initiation regime 6.7.1 Smoke control dampers for systems with automatic activation (AA) 6.7.1.1 Duct mounted smoke control dampers 6.7.1.2 Compartment boundary mounted smoke control dampers fire resistance test |
29 | 6.7.1.3 Compartment boundary mounted smoke control dampers maintenance of opening test 6.7.2 Smoke control damper for systems with manual activation (MA) 6.7.2.1 Duct mounted smoke control dampers |
30 | 6.7.2.2 Compartment boundary mounted smoke control dampers fire resistance test 6.7.2.3 Compartment boundary mounted smoke control dampers maintenance of opening test |
31 | 6.8 HOT400/30 extension test 6.9 Special constructions 7 Test procedure 7.1 Fire resistance or elevated temperature and maintenance of opening test for duct mounted smoke control dampers 7.1.1 General 7.1.2 Pre-test calibration 7.1.2.1 Oxygen-measuring instrument |
32 | 7.1.2.2 Perforated plate 7.1.2.3 Ambient leakage measurement 7.1.2.4 Extraction fan |
33 | 7.1.3 Ignition of furnace 7.1.4 Operate the damper 7.1.5 Furnace conditions 7.1.6 Thermocouples for insulation (I) 7.1.6.1 Thermocouples at the compartment boundary outside of the furnace 7.1.6.2 Thermocouples on the duct mounted damper outside the furnace on blades or grille |
34 | 7.1.7 Oxygen measurements 7.1.7.1 Smoke control damper for systems with automatic activation 7.1.7.2 Smoke control damper for systems with manual activation 7.1.8 General observations 7.1.9 Reduction of cross-section/maintenance of opening 7.1.10 Leakage calculations 7.1.11 Termination of test |
35 | 7.2 Fire resistance tests for smoke control dampers mounted in a compartment boundary 7.2.1 General 7.2.2 Pre-test calibration 7.2.2.1 Ambient leakage measurement 7.2.2.2 Extraction fan 7.2.3 Ignition of furnace 7.2.4 Operate the damper 7.2.5 Furnace conditions 7.2.6 Thermocouples for insulation (I) 7.2.6.1 Thermocouples at the compartment boundary outside of the furnace |
36 | 7.2.7 General observations 7.2.8 Leakage calculations 7.2.9 Termination of test 7.3 Maintenance of opening test for compartment boundary mounted smoke control dampers 7.3.1 General 7.3.2 Pre-test calibration 7.3.2.1 Oxygen-measuring instrument 7.3.2.2 Perforated plate 7.3.2.3 Ambient leakage measurement |
37 | 7.3.2.4 Extraction fan 7.3.3 Ignition of furnace 7.3.4 Operate a damper 7.3.5 Furnace conditions 7.3.6 Thermocouples for insulation (I) 7.3.6.1 Thermocouples at the compartment boundary outside of the furnace 7.3.7 General observations |
38 | 7.3.8 Reduction of cross-section/maintenance of opening 7.3.9 Termination of test 8 Performance criteria 8.1 Integrity 8.1.1 General 8.1.2 Integrity at perimeter 8.1.2.1 Duct mounted SCDs |
39 | 8.1.2.2 Compartment boundary mounted SCDs |
42 | 8.2 Insulation 8.2.1 General 8.2.2 Thermocouples at the compartment boundary outside of the furnace 8.3 Reduced leakage |
43 | 8.4 Times and observations 8.5 Other 9 Test report 9.1 General |
44 | 9.2 Duct mounted single and multi-compartment tests |
45 | 9.3 Compartment boundary compartmentation test 9.4 Compartment boundary maintenance of opening test |
46 | 10 Direct field of application of test results (DIAP) 10.1 Compartment boundary mounted smoke control dampers 10.2 Smoke control damper sizes 10.3 Duct mounted smoke control damper mounting positions 10.4 Distance between mounting positions in compartment boundary applications 10.5 Blade pivot axis |
47 | 10.6 Pressure difference 10.7 Elevated temperatures 10.8 Cycling tests 10.8.1 Smoke control dampers meeting the cycling requirements for modulating applications 10.8.2 Smoke control dampers meeting the cycling requirements for use with combined smoke control and general HVAC applications and for smoke control systems that are cycle checked every day 10.8.3 Smoke control dampers meeting the cycling requirements for smoke control dampers that are operated only in the case of emergency 10.8.4 Load application 10.9 Initiation method |
48 | 10.10 Duct mounted smoke control dampers – application to ducts other than that tested 10.10.1 Single compartment smoke control dampers 10.10.2 Multi compartment smoke control dampers |
49 | 10.11 Compartment mounted smoke control dampers – application to shafts, walls and constructions other than that tested 10.11.1 Single compartment smoke control dampers 10.11.2 Multi compartment smoke control dampers 10.12 Standard damper open or closed position |