Ventilation for buildings. Air terminal devices. Aerodynamic testing of damper and valves
Published By | Publication Date | Number of Pages |
BSI | 2024 | 34 |
This document specifies methods for the testing and rating of dampers and valves used in air distribution systems with pressure differences up to 2 000 Pa. The tests incorporated in this document will address: – leakage past a closed damper or valve (for classification, see Annex C); – casing leakage (for classification, see Annex C); – flow rate/pressure requirement characteristics; – torque: (see Annex A); – thermal transmittance: (see Annex B). The tests specified above are applicable to the following: – measurement of leakage past a closed damper or valve; – measurement of casing leakage; – determination of flow rate and pressure requirements; – measurement of torque characteristics (see Annex A); – measurement of thermal transfer characteristics to determine insulation properties (see Annex B). This document does not apply to the acoustic testing of dampers and valves. NOTE Certain aspects of the dynamic performance of dampers and/or valves are dependent upon the air distribution system to which they are connected and are, therefore, difficult to measure in isolation. Such considerations have led to the omission of these aspects of the dynamic performance measurements from this document. Also, in common with other air distribution components, the results from tests carried out in accordance with this document might not be directly applicable if the damper or valve is situated in an area of non-uniform flow.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
6 | 1 Scope 2 Normative references |
7 | 3 Terms, definitions, symbols and suffixes 3.1 Terms and definitions 3.2 Symbols |
8 | 3.3 Suffixes 4 Instrumentation 4.1 Air flow rate measurement |
9 | 4.2 Pressure measurement 4.3 Temperature measurement |
10 | 5 Leakage tests 5.1 General 5.2 Damper and valve leakage 5.3 Casing leakage |
11 | 6 Flow rate and pressure tests 6.1 Ducted method |
12 | 6.2 Chamber method 6.2.1 General 6.2.2 Size relationship 6.2.3 Tests |
13 | 6.3 Calculations and report |
20 | Annex A (informative)Mechanical testing of dampers and valves A.1 General A.2 Instrumentation: Torque measurement A.3 Pressure test to determine limiting value for structural stability |
21 | A.4 Torque tests to determine the torque required to operate the damper or valve and the limiting value to avoid structural damage A.4.1 Torque required to operate damper A.4.2 Maximum permitted torque |
23 | Annex B (informative)Thermal transmittance through dampers and valves B.1 General B.2 Thermal loss test using a substitution method |
26 | Annex C (normative)Classification of a damper or valve leakage C.1 General C.2 Leakage through closed blade(s) |
28 | C.3 Casing leakage |
30 | Annex D (informative)Effect of duct configuration on pressure loss coefficient D.1 General |
31 | D.2 Application of correction factor |