Shopping Cart

No products in the cart.

BS EN 61300-3-51:2014

$102.76

Fibre optic interconnecting devices and passive components. Basic test and measurement procedures – Examinations and measurements. Pin gauge withdrawal force for rectangular ferrule multi-fibre connectors

Published By Publication Date Number of Pages
BSI 2014 22
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC 61300-3-51:2014 is intended to describe the procedure required to measure the pin gauge withdrawal force for rectangular ferrule multi-fibre connectors. This measurement can be used as an alternative to the measurement of the pin gauge insertion force, both of which evaluate the fit of the pin gauge(s) into the guide pin hole(s) of the female-type connector. The experimental verification of interchangeability between them is shown in Annex A. For the male-type connector, IEC 61300-3-49 is applied to evaluate how securely the guide pins are retained in the guide holes. Keywords: pin gauge withdrawal force, pin gauge insertion force

PDF Catalog

PDF Pages PDF Title
6 English
CONTENTS
8 1 Scope
2 Normative references
9 3 General description
3.1 General
3.2 Test conditions
4 Apparatus
4.1 Fixture
4.2 Pin gauge chuck
4.3 Plug gauge chuck
4.4 Pin gauge
Tables
Table 1 – Test conditions
10 4.5 Plug gauge
Figures
Figure 1 – Pin gauge
Figure 2 – Plug gauge for guide pin holes
Table 2 – Dimensions of the pin gauge
11 4.6 Weight
4.7 Tensile testing machine
5 Procedure
5.1 Method A: Method using the weight (Figure 3)
Table 3 – Dimensions for plug gauge for guide pin holes
12 5.2 Method B: Method using the tensile testing machine (Figure 4)
Figure 3 – Method A for examination of pin gauge/plug gauge withdrawal force (method using the weight)
13 Figure 4 – Method B for examination of pin gauge/plug gauge withdrawal force (method using the tensile testing machine)
14 6 Details to be specified
15 Annex A (informative) Experimental verification of the interchangeability between the pin gauge insertion force and the pin gauge withdrawal force
A.1 General
A.2 Measurement system
A.3 Measurement sample
Figure A.1 – Measurement system
16 A.4 Measurement procedure
A.5 Measurement results
Figure A.2 – Insertion/withdrawal force measurement results
Table A.1 – Guide hole pitch of measurement samples
17 A.6 Conclusion
18 Annex B (informative) Experimental verification of compatibility of Method A (method using the weight) and Method B (method using the tensile testing machine)
Figure B.1 – Relation between the withdrawal force values measured by Method A and Method B
19 Bibliography
BS EN 61300-3-51:2014