IEC 61347-2-9:2012 series specifies particular safety requirements for electromagnetic controlgear for discharge lamps such as high-pressure mercury vapour, low-pressure sodium vapour, high-pressure sodium vapour and metal halide lamps. The standard covers inductive-type electromagnetic controlgear for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz, associated with discharge lamps, having rated wattages, dimensions and characteristics as specified in IEC 60188, IEC 60192 and IEC 60662. This second edition cancels and replaces the first edition published in 2000, Amendment 1:2003 and Amendment 2:2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) the addition of a new Clause 14; b) the word “ballast” is changed to “electromagnetic controlgear”. This publication is to be read in conjunction with /2.

PDF Catalog

PDF Pages PDF Title
7 English
CONTENTS
9 INTRODUCTION
10 1 Scope
2 Normative references
3 Terms and definitions
11 4 General requirements
4.1 General
4.2 Capacitors and other components
4.3 Thermally protected electromagnetic controlgear
5 General notes on tests
12 6 Classification
7 Marking
7.1 General
7.2 Mandatory markings
7.3 Information to be provided, if applicable
7.4 Other information
13 8 Protection against accidental contact with live parts
9 Terminals
10 Provisions for earthing
11 Moisture resistance and insulation
12 Electric strength
13 Thermal endurance test for windings
14 Electromagnetic controlgear heating
14.1 General
14.2 Test requirements
Table 1 – Test voltages for electromagnetic controlgear generating pulse voltages
14 14.3 Normal operating condition
14.4 Abnormal operating condition
15 Table 2 – Maximum temperatures
16 Table 3 – Limiting temperatures of windings under abnormal operating conditions and at 110 % of rated voltage for electromagnetic controlgear subjected to endurance test duration of 30 days
Table 4 – Limiting temperatures of windings under abnormal operating conditions and at 110 % of rated voltage for electromagnetic controlgear marked D6 which are subjected to an endurance test duration of 60 days
17 15 High-voltage impulse testing
15.1 General
15.2 Test for electromagnetic controlgear operating with lamp with external starting devices
15.3 Test for electromagnetic controlgear operating with lamps with internal starting devices
18 Figure 1 – Test circuit for electromagnetic controlgear for lamps with integral starting devices
19 16 Fault conditions
17 Construction
18 Creepage distances and clearances
19 Screws, current-carrying parts and connections
20 Resistance to heat, fire and tracking
21 Resistance to corrosion
22 No-load output voltage
20 Annex A (normative) Test to establish whether a conductive part is a live part which may cause an electric shock
21 Annex B (normative) Particular requirements for thermally protected lamp electromagnetic controlgear
22 Annex C (normative) Particular requirements for electronic lamp controlgear with means of protection against overheating
23 Annex D (normative) Requirements for carrying out the heating tests of thermally protected lamp electromagnetic controlgear
24 Annex E (normative) Use of constant S other than 4 500 in tw tests
25 Annex F (normative) Draught-proof enclosure
26 Annex G (normative) Explanation of the derivation of the values of pulse voltages
27 Annex H (normative) Tests
28 Annex I (normative) Method for selection of varistors
I.1 General
I.2 Selection of the varistors
29 Annex J (informative) Explanation of electromagnetic controlgear temperatures
J.1 General
J.2 Endurance
30 J.3 Electromagnetic controlgear heating
J.4 Test arrangement
31 Figure J.1 – Test hood for electromagnetic controlgear heating test
Figure J.2 – Test corner for electromagnetic controlgear heating
32 Annex K (normative) Additional requirements for built-in electromagnetic controlgear with double or reinforced insulation
33 Bibliography