BS EN IEC 61788-22-3:2022
$142.49
Superconductivity – Superconducting strip photon detector. Dark count rate
Published By | Publication Date | Number of Pages |
BSI | 2022 | 30 |
IEC 61788-22-3:2022 is applicable to the measurement of the dark count rate (DCR, RD) of superconductor strip photon detectors (SSPDs). It specifies terms, definitions, symbols and the measurement method of DCR that depends on the bias current (Ib) and operating temperature (T). NOTE The data of measurement results in Annex A are based on measurements of one institute only. The standard will be updated after the data of a complete round robin test are available.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
4 | European foreword Endorsement notice |
5 | English CONTENTS |
7 | FOREWORD |
9 | INTRODUCTION |
11 | 1 Scope 2 Normative references 3 Terms, definitions and abbreviated terms 3.1 Terms and definitions |
12 | Figures Figure 1 – Example of one dark count pulse in the pulse train in inset |
13 | 3.2 Abbreviated terms 4 Principle of the measurement method |
14 | 5 Apparatus 5.1 Detector packaging 5.2 Cryogenic system Figure 2 – Schematic curve of RD as a function of normalized bias current |
15 | Figure 3 – Schematic diagram of a typical DCR measurement system |
16 | 5.3 Measurement system Figure 4 – Equivalent circuit of the DCR measurement |
17 | 6 Measurement procedure 6.1 Measurement of temperature 6.2 Measurement of switching current |
18 | 6.3 Measurement of RD Figure 5 – Typical current-voltage (I-U) curve of an SSPD |
19 | 7 Standard uncertainty 7.1 Type A uncertainty 7.2 Type B uncertainty |
20 | 7.3 Uncertainty budget table |
21 | 7.4 Uncertainty requirement 8 Test report 8.1 Identification of device under test (DUT) 8.2 Measurement conditions and results Tables Table 1 – Uncertainty budget table for RD |
22 | 8.3 Miscellaneous optional report |
23 | Annex A (informative)Results of the round robin test A.1 DUT packages A.2 Measurement conditions Figure A.1 – Photograph of the DUT with an SSPD and a temperature sensor |
24 | A.3 Measurement results |
25 | Figure A.2 – I-U curve and RD curves Table A.1 – Test data of DUT |
26 | Table A.2 – Temperature sensitivity and bias current sensitivityabove a normalized bias current of 0,9 Table A.3 – uA and uB above a normalized bias current of 0,9 Table A.4 – Budget table for RD at a bias point of 5,25 µA (Ib/Isw = 0,955) |
27 | Table A.5 – DCR values measured at a bias point of 5,25 µA (Ib/Isw = 0,955) Table A.6 – Temperature measurement |
28 | Bibliography |