BS EN IEC 62271-204:2022 – TC:2023 Edition

$258.95

Tracked Changes. High-voltage switchgear and controlgear – Rigid gas-insulated transmission lines for rated voltage above 52 kV

Published By Publication Date Number of Pages
BSI 2023 140
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of IEC 62271 applies to rigid HV gas-insulated transmission lines (GIL) in which the insulation is obtained, at least partly, by a non-corrosive insulating gas, other than air at atmospheric pressure, for alternating current of rated voltages above 52 kV, and for service frequencies up to and including 60 Hz. It is intended that this international standard shall be used where the provisions of IEC 62271-203 do not cover the application of GIL (see Note 3). At each end of the HV gas-insulated transmission line, a specific element may be used for the connection between the HV gas-insulated transmission line and other equipment like bushings, power transformers or reactors, cable boxes, metal-enclosed surge arresters, voltage transformers or GIS, covered by their own specification. Unless otherwise specified, the HV gas-insulated transmission line is designed to be used under normal service conditions. Note 1 to entry: In this international standard, the term “HV gas-insulated transmission line” is abbreviated to “GIL”. Note 2 to entry: In this international standard, the word “gas” means gas or gas mixture, as defined by the manufacturer. Note 3 to entry: Examples of GIL applications are given: – where all or part of the HV gas-insulated transmission line is directly buried; or – where the HV gas-insulated transmission line is located, wholly or partly, in an area accessible to public; or – where the HV gas-insulated transmission line is long (typically longer than to 500 m) and the typical gas compartment length exceeds the common practice of GIS technology.

PDF Catalog

PDF Pages PDF Title
81 undefined
84 Annex ZA (normative)Normative references to international publicationswith their corresponding European publications
86 English
CONTENTS
87 FOREWORD
89 1 Scope
2 Normative references
90 3 Terms and definitions
92 4 Normal and special service conditions
93 5 Ratings
94 6 Design and construction
98 Table 1 – Second characteristic numeral of IP coding
105 7 Type tests
112 8 Routine tests
113 9 Guide to the selection of GIL (informative)
114 10 Information to be given with enquiries, tenders and orders (informative)
116 11 Transport, storage, installation, operating instructions and maintenance
122 12 Safety
123 13 Influence of the product on the environment
124 Annex A (informative) Estimation of continuous current
129 Annex B (informative) Earthing
132 Figure B.1 – Example of earthing system together with active anti-corrosion system in the case of solid bonding of the enclosure at both ends
133 Annex C (informative) Long-term testing of buried installations
135 Annex D (normative) Requirements for welds on pressurized parts
Table D.1 – Quantity of NDTs
136 Table D.2 – Acceptance criteria of imperfections
137 Bibliography
BS EN IEC 62271-204:2022 - TC
$258.95