BS IEC 61156-11:2019

$142.49

Multicore and symmetrical pair/quad cables for digital communications – Symmetrical single pair cables with transmission characteristics up to 600 MHz. Horizontal floor wiring. Sectional specification

Published By Publication Date Number of Pages
BSI 2019 28
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of IEC 61156 describes cables intended to be used for transmission of 1 Gbps over a single twisted pair for office, home and industrial application. An example of existing application is 1000BASE-T1, see ISO/IEC TR 11801-99061. The transmission characteristics of these cables are specified up to a frequency of 600 MHz and at a temperature of 20 °C. The cable type recognised is intended to be used for shielded channels with a nominal length of 40 m. Possible designs are U/FTP, X/UTP and X/FTP, where X stands for F, S or SF. A blank detail specification can be found in Annex A.

These cables can comprise more than one pair in the event that several systems are operated in parallel. In this case, refer to Clause 7 of this document.

The cables covered by this document are intended to operate with voltages and currents normally encountered in communication systems. While these cables are not intended to be used in conjunction with low impedance sources, for example, the electric power supplies of public utility mains, they are intended to be used to support the delivery of low-voltage remote powering applications.

PDF Catalog

PDF Pages PDF Title
2 undefined
4 CONTENTS
7 FOREWORD
9 1 Scope
2 Normative references
10 3 Terms and definitions
4 Installation considerations
4.1 General remarks
4.2 Bending radius of installed cable
4.3 Climatic conditions
5 Materials and cable construction
5.1 General remarks
11 5.2 Cable construction
5.3 Conductor
5.4 Insulation
5.5 Cable element
5.6 Screening of the cable element
5.7 Cable make-up
5.8 Screening of the cable core
5.9 Sheath
12 5.10 Identification
5.11 Finished cable
6 Characteristics and requirements
6.1 General remarks
6.2 Electrical characteristics and tests
6.2.1 Conductor resistance
6.2.2 Resistance unbalance
13 6.2.3 Dielectric strength
6.2.4 Insulation resistance
6.2.5 Mutual capacitance
6.2.6 Capacitance unbalance
6.2.7 Transfer impedance
6.2.8 Coupling attenuation
Tables
Table 1 – Transfer impedance
14 6.2.9 Current-carrying capacity
6.3 Transmission characteristics
6.3.1 Velocity of propagation (phase velocity)
6.3.2 Phase delay and differential delay (delay skew)
6.3.3 Attenuation (α)
Table 2 – Coupling attenuation
15 6.3.4 Unbalance attenuation (TCL and EL TCTL)
6.3.5 Alien (exogenous) near-end crosstalk (PS ANEXT)
Table 3 – Attenuation equation constants
Table 4 – TCL requirements
Table 5 – EL TCTL requirements
16 6.3.6 Alien (exogenous) far-end crosstalk (PS AACR-F)
6.3.7 Alien (exogenous) crosstalk of bundled cables
6.3.8 Impedance
6.3.9 Return loss (RL)
Table 6 – PS ANEXT requirements
Table 7 – PS AACR-F requirements
17 6.4 Mechanical and dimensional characteristics and requirements
6.4.1 Dimensional requirements
6.4.2 Elongation at break of the conductor
6.4.3 Tensile strength of the insulation
6.4.4 Elongation at break of the insulation
6.4.5 Adhesion of the insulation to the conductor
6.4.6 Elongation at break of the sheath
6.4.7 Tensile strength of the sheath
6.4.8 Crush test of the cable
6.4.9 Impact test of the cable
Table 8 – RL requirements
18 6.4.10 Bending under tension
6.4.11 Repeated bending of the cable
6.4.12 Tensile performance of the cable
6.4.13 Shock-test requirements of the cable
6.4.14 Bump-test requirements of the cable
6.4.15 Vibration-test requirements of a cable
6.5 Environmental characteristics
6.5.1 Shrinkage of the insulation
6.5.2 Wrapping test of the insulation after thermal ageing
6.5.3 Bending test of insulation at low temperature
6.5.4 Elongation at break of the sheath after ageing
6.5.5 Tensile strength of the sheath after ageing
6.5.6 Sheath pressure test at high temperature
19 6.5.7 Cold bend test of the cable
6.5.8 Heat shock test
6.5.9 Damp heat steady state
6.5.10 Solar radiation
6.5.11 Solvents and contaminating fluids
6.5.12 Salt mist and sulphur dioxide
6.5.13 Water immersion
6.5.14 Hygroscopicity
6.5.15 Wicking
6.5.16 Flame propagation characteristics of a single cable
6.5.17 Flame propagation characteristics of bunched cables
6.5.18 Halogen gas evolution
20 6.5.19 Smoke generation
6.5.20 Toxic gas emission
6.5.21 Integrated fire test method for cables in environmental air handling spaces
7 Bundled cable requirements
7.1 General
7.2 Single pairs sharing one sheath
7.2.1 General
7.2.2 Near-end crosstalk (NEXT)
Table 9 – NEXT and PS NEXT requirements
21 7.2.3 Attenuation to crosstalk ratio far-end (PS ACR-F)
Table 10 – ACR-F and PS ACR-F requirements
22 Annex A (informative) Blank Detail Specification
27 Bibliography