BS ISO 11799:2024
$189.07
Information and documentation. Document storage requirements for archive and library materials
Published By | Publication Date | Number of Pages |
BSI | 2024 | 50 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
7 | Foreword |
8 | Introduction |
9 | 1 Scope 2 Normative references 3 Terms and definitions |
10 | 4 Sustainability — Collections storage and preservation 4.1 General |
11 | 4.2 Specifying storage spaces/conditions 5 Design planning 5.1 Identify design participants |
12 | 5.2 Establish design priorities 5.3 Establish design specifications |
13 | 5.4 Risk assessment 5.4.1 General 5.4.2 Hazards to collections |
14 | 5.4.3 Site risk assessment |
15 | 5.5 Location of repository within structure 5.6 Subgrade storage considerations |
16 | 6 Building materials and assembly 6.1 Building fabric and environmental protection 6.1.1 General 6.1.2 Insulation and thermal stability (Thermal) |
17 | 6.1.3 Airtightness 6.1.4 Hygroscopicity/permeability (Vapor) 6.1.5 Air pressurization and repositories |
18 | 6.1.6 Modelling 6.2 Building materials and stability 6.2.1 General 6.2.2 Foundations and ground-bearing slabs |
19 | 6.2.3 Exterior 6.2.4 Roof |
20 | 6.2.5 Interior — General 6.2.6 Interior finishes 6.2.7 Off gassing of construction materials |
21 | 6.2.8 Building equilibration 6.2.9 Floors |
22 | 6.3 Mechanical/HVAC systems 6.3.1 General 6.3.2 Equipment location 6.3.3 Design considerations |
25 | 6.4 Security 6.4.1 General 6.4.2 Protection against intruders 6.4.3 Doors and circulation routes |
26 | 6.4.4 Services 6.4.5 Windows 7 Furniture and lighting considerations 7.1 Furniture 7.1.1 General 7.1.2 Material requirements 7.1.3 Furniture configuration in the repository ambient conditions |
27 | 7.1.4 Types of storage furniture |
28 | 7.1.5 Mobile shelving systems 7.2 Lighting 7.2.1 General |
29 | 7.2.2 Repository 7.2.3 Artificial light sources |
30 | 7.2.4 Natural light sources 7.2.5 Collection-level mitigation strategies for reducing light exposure in existing repositories |
31 | 8 Environmental monitoring 8.1 General 8.2 Methodology 8.2.1 General 8.2.2 Equipment 8.2.3 Deployment and sample rates |
32 | 8.2.4 Data retention and analysis 8.2.5 Other data sources |
33 | 9 Building-related hazards to collections 9.1 Pest considerations 9.2 Water considerations 9.3 Fire protection and prevention 9.3.1 General |
34 | 9.3.2 Fire risk assessment 9.3.3 Structural fire protection |
35 | 9.3.4 Minimizing fire hazard in an electrical system |
36 | 9.3.5 Minimizing fire hazards in ventilation plant and equipment 9.3.6 Fire detection and firefighting |
37 | 9.4 Seismic |
38 | 9.5 Power/Emergency power 9.5.1 General 9.5.2 Emergency power 10 Facility records and maintenance 10.1 Facility records 10.2 Maintenance |
40 | Annex A (informative) Automatic fire-fighting systems |
42 | Annex B (informative) Recommended climatic conditions for the long-term storage of archive and library materials |
45 | Annex C (informative) Environmental transitions for materials |
46 | Bibliography |