Shopping Cart

No products in the cart.

BSI 19/30406447 DC:2019 Edition

$13.70

BS EN 62606 AMD2. General requirements for arc fault detection devices

Published By Publication Date Number of Pages
BSI 2019 17
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
5 1 Scope
2 Normative references
3 Terms and definitions
3.1
3.2
3.3
3.4 arc fault detection unit
4 Classification
4.1 According to the method of construction
6 4.1.1
4.1.2 AFDD as one single device, comprising an AFD unit and a protective device.
4.1.2.1 AFD unit integrated in a protective device complying with one of the following standards: IEC 60898-1, IEC 61008-1, IEC 61009-1 or IEC 62423.
4.1.2.2 AFD unit assembled by the manufacturer to a protective device complying with one of the following standards: IEC 60898-1, IEC 61008-1, IEC 61009-1 or IEC 62423.
5 Characteristics of AFDDs
5.1
5.2
5.3
5.4 Standard values of rated impulse withstand voltage (Uimp)
6 Marking and other product information
7 Standard conditions for operation in service and for installation
7.1 Standard conditions
8 Requirements for construction and operation
8.1 General
7 8.2
8.3
8.4
8.5 Temperature rise
8.5.1 Temperature-rise limits
8.6 Operating characteristics
8.6.1 Operating characteristics of the protective device part
9 Testing procedure
9.1 General
9.1.1 General testing procedure for the different type of AFDDs
8 9.1.2 The characteristics of AFDDs are checked by means of type tests
9.2
9.3
9.4
9.5
9.6
9.7
9.7.1
9.7.2
9.7.3
9.7.4
9.7.5
9.7.6 Capability of control circuits connected to the main circuit in respect of withstanding high DC voltages due to insulation measurements
9.7.7
9.7.7.1
9.7.7.2
9.7.7.3
9.7.7.4
9.7.7.5 Verification of the behaviour of components bridging the basic insulation
9.8
9.9
9.9.1
9.9.2 Series arc fault tests
9.9.2.1 General
9 9.9.2.2
9.9.2.3
9.9.2.4
9.9.2.5 Test at the temperature limits
9.9.2.6
9.9.2.7
9.9.2.8 Verification of correct operation in case of arc in a three-phase system with unbalanced load
9.9.3
9.9.4
9.9.4.1
9.9.4.2 Masking test with inhibition loads
10 9.9.4.3
9.9.4.4
9.9.4.5 Masking test with inhibition loads for three-pole and four-pole AFDDs
9.9.5
9.9.5.1
9.9.5.2
9.9.5.3
9.9.5.4 Test with various disturbing loads for single-pole AFDD with two current path and two-pole AFDD
9.9.5.4 Test with various disturbing loads for single-pole AFDD with two current paths, two-pole AFDDs and four-pole AFDDs
11 9.9.5.5 Test with various disturbing loads for three-pole and four-pole AFDDs
9.10 Verification of mechanical and electrical endurance
9.10.1
9.10.2
9.10.3 Condition of the AFDD after test
9.11 Verification of the behaviour of the AFDD under short-circuit conditions
9.11.1 General
9.11.2 Short-circuit tests for AFDDs according to 4.1.1
9.11.2.1
9.11.2.2 General conditions for test
9.11.2.3 Verification of the rated making and breaking capacity (Im)
12 9.11.2.4 Verification of the rated making and breaking capacity on one pole (Im1) of AFDDs and their suitability for use in IT systems
9.12 Verification of resistance to mechanical shock and impact
9.12.1
9.12.2
9.12.2.1
9.12.2.2
9.12.2.3 AFDDs designed to be mounted on a rail are mounted as for normal use on a rail rigidly fixed on a vertical rigid wall, but without cables being connected and without any cover or cover-plate.
9.13 Test of resistance to heat
9.13.1 The samples, without removable covers, if any, are kept for 1 h in a heating cabinet at a temperature of 100 C ± 2 C; removable covers, if any, are kept for 1 h in the heating cabinet at a temperature of 70 C ± 2 C.
9.14
9.15
9.16
9.17
9.18
9.18.1
9.18.2
9.18.2.1
9.18.2.2 Test results
9.19
9.19.1
9.19.2
9.19.2.1
9.19.2.2
9.19.2.3
9.19.2.4 Testing procedure
9.19.2.5
9.19.2.6 Final verification
9.19.3 Test with temperature of 40 C
13 9.20 Verification of ageing of electronic components
9.21 Electromagnetic compatibility (EMC)
9.21.1
9.21.2
9.21.3
9.21.4
9.21.4.1
9.21.4.2 Criteria A
9.21.4.3 Criteria B
9.21.4.4 Criteria C
14 Annex A (normative) Test sequence and number of samples to be submitted for certification purposes
15 Annex D (normative) Additional requirements and tests for AFDDs according to the classification 4.1.3 designed to be assembled on site together with a main protective device (circuit-breaker or RCCB or RCBO)
D.6 Type tests and verifications
D.6.3 Tests on assembled AFDDs
16 Annex E (normative) Routine tests
E.3 Electric strength test
17 Annex ID (informative) Follow-up testing program for AFDDs
BSI 19/30406447 DC
$13.70