BSI PD ISO/TS 21396:2017:2018 Edition
$142.49
Rubber. Determination of mass concentration of tire and road wear particles (TRWP) in soil and sediments. Pyrolysis-GC/MS method
Published By | Publication Date | Number of Pages |
BSI | 2018 | 32 |
This document specifies a method for the determination of the soil or sediment mass concentration (μg/g) of tyre and road wear particles (TRWP) in environmental samples.
This document establishes principles for soil or sediment sample collection, the generation of pyrolysis fragments from the sample, and the quantification of the generated polymer fragments. The quantified polymer mass is used to calculate the concentration of TRWP in soil or sediment. These quantities are expressed on a TRWP basis, which includes the mass of tyre tread and mass of road wear encrustations, and can also be expressed on a tyre rubber polymer or tyre tread basis.
NOTE Tyre and road wear particles are a discrete mass of elongated particles generated at the frictional interface between the tyre and roadway surface during the service life of a tyre. The particles consist of tyre tread enriched with mineral encrustations from the roadway surface.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | National foreword |
6 | Foreword |
7 | Introduction |
9 | 1 Scope 2 Normative references 3 Terms and definitions |
10 | 4 Principle 5 Reagents |
11 | 6 Apparatus |
13 | 7 Specimen preparation laboratory 8 Measuring range 9 Limit of detection |
14 | 10 Procedure 10.1 General 10.2 Sample collection 10.3 Deuterated internal standard preparation |
15 | 10.4 Calibration curve preparation 10.4.1 Stock solutions 10.4.2 Calibration curves |
16 | 10.5 Sample preparation 10.5.1 Oven drying 10.5.2 Sieving and homogenization 10.6 Sample measurement 10.6.1 Sample mass 10.6.2 Internal standard addition |
17 | 10.6.3 Pyrolysis-gas chromatograph/mass spectrometer measurement 11 Analysis 11.1 TRWP detection limit 11.2 Quantity of tyre polymer in the sample |
18 | 11.3 Mass concentration of TRWP 12 Performance characteristics 12.1 General 12.2 Specific performance characteristics 12.3 Method detection limit 13 Test report |
20 | Annex A (informative) Recipe for calibration curves and stock solutions |
22 | Annex B (informative) Curie-point pyrolyser |
23 | Annex C (informative) Representative calibration curves and pyrograms |
28 | Annex D (normative) Calculation of TRWP detection limits |
29 | Annex E (normative) Calculation of results using dimer markers |
30 | Bibliography |