FEMA E 74 2012
$53.30
FEMA E-74, Reducing the Risks of Nonstructural Earthquake Damage—A Practical Guide, Fourth Edition
Published By | Publication Date | Number of Pages |
FEMA | 2012 | 885 |
None
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 0-82 00_FEMAE-74-Cover |
2 | 1-82 01_FEMAE-74-Preface |
3 | 02_FEMAE-74-TableofContents |
6 | 03_FEMAE-74_Chapter1 |
13 | 04_FEMAE-74-Chapter2 |
42 | 5-82.pdf 05_FEMAE-74_Chapter3 3.1 Survey of Nonstructural Components |
44 | 3.1.1 Survey Forms |
47 | 3.2 Estimating Seismic Risk 3.2.1 Estimating Seismic Shaking Intensity |
50 | 3.2.2 Estimating Seismic Risk Ratings |
51 | 3.2.3 Assigning Priority Ratings 3.2.4 Application of Nonstructural Guidelines |
53 | 06_FEMAE_74_Chapter4 4.1 Program Objectives and Scope |
54 | 4.1.1 Voluntary vs. Mandatory Risk Reduction |
55 | 4.1.2 Performance-Based Design Concepts |
62 | 4.1.3 Legal Considerations |
63 | 4.2 Design considerations |
65 | 4.3 Project planning and implementation strategies |
67 | 4.3.1 Integration with Maintenance Programs 4.3.2 Integration with Remodeling |
68 | 4.3.3 Phased or Incremental Upgrading 4.3.4 Integration with Purchasing 4.4 Responsibility and Program Management 4.4.1 Responsibility |
72 | 4.4.2 Sustaining Protection 4.4.3 Program Evaluation |
73 | 4.5 Cost benchmarks – Examples 4.5.1 Example 1 – Manufacturing Facility |
74 | 4.5.2 Example 2 – School District |
75 | 4.5.3 Example 3 – California Hospital |
77 | 07_FEMAE-74_Chapter5 5.1 Program Objectives and Scope |
79 | 5.1.1 Voluntary vs Mandatory Risk Reduction |
80 | 5.1.2 Performance-Based Design concepts |
82 | 5.2 Design Considerations |
83 | 5.3 Building code requirements 5.3.1 2012 Edition of the International building code (IBC 2012) |
87 | 5.3.2 Enforcement of Code Requirements |
88 | Plan Review Construction Inspection |
89 | 5.3.3 Requirements for Contents 5.3.4 Other Standards and Protocols |
90 | 5.3.5 Validation and Refinement of Code Requirements 5.4 Responsibility and Project Management |
92 | 5.4.1 Example: Responsibility Matrix |
93 | 5.4.2 Example: Seismic Code Block, Saint Louis county, Missouri |
95 | 08_FEMAE-74_Chapter6_part1 6.1 Protective Measures 6.1.1 Common Sense Measures |
96 | 6.1.2 Nonstructural Component Protection Measures |
98 | 6.1.3 building Protection Measures |
99 | 6.2 Nonstructural Component examples |
100 | 6.2.1 Typical Mitigation Details Non-Engineered (NE) Details Prescriptive (PR) Details |
101 | Engineering Required (ER) Details |
105 | 09_FEMAE-74_Chapter6_3_1_1 6.3 Architectural Components 6.3.1 Exterior Wall Components 6.3.1.1 Adhered Veneer Provisions BUILDING CODE PROVISIONS Retrofit standard Provisions |
106 | Typical Causes of Damage |
107 | Damage Examples |
110 | Seismic Mitigation Considerations |
111 | Mitigation Examples |
112 | Mitigation Details |
113 | 10_FEMAE-74-Chapter6_3_1_2 6.3 Architectural Components 6.3.1 Exterior Wall Components 6.3.1.2 Anchored Veneer Provisions Building Code Provisions |
114 | Retrofit Standard Provisions Typical Causes of Damage |
115 | Damage Examples |
117 | Seismic Mitigation Considerations Mitigation Examples |
118 | Mitigation Details |
119 | 11_FEMAE-74-Chapter6_3_1_3 6.3 Architectural Components 6.3.1 Exterior Wall Components 6.3.1.3 Prefabricated Panels Provisions Building Code Provisions Retrofit Standard Provisions |
120 | Typical Causes of Damage |
121 | Damage Examples |
127 | Seismic Mitigation Considerations |
130 | Mitigation Details |
132 | 12_FEMAE-74-Chapter6_3_1_4 6.3 Architectural Components 6.3.1 Exterior Wall Components 6.3.1.4 Glazing Provisions Building Code Provisions Retrofit Standard Provisions |
133 | Typical Causes of Damage |
134 | Damage Examples |
140 | Seismic Mitigation Considerations |
141 | Mitigation Details |
142 | 13_FEMAE-74-Chapter6_3_1_5 6.3 Architectural Components 6.3.1 Exterior Wall Components 6.3.1.5 Glass block Provisions Building Code Provisions Retrofit Standard Provisions |
143 | Typical Causes of Damage |
144 | Damage Examples |
146 | Seismic Mitigation Considerations |
148 | Mitigation Examples |
150 | Mitigation Details |
152 | 14_FEMAE-74-Chapter6_3_2_1 6.3 Architectural Components 6.3.2 Interior Partitions 6.3.2.1 Interior Partition Walls, Heavy Provisions Building Code Provisions Retrofit Standard Provisions |
153 | Typical Causes of Damage |
154 | Damage Examples |
158 | Seismic Mitigation Considerations |
159 | Mitigation Examples |
161 | Mitigation Details |
163 | 15_FEMAE-74-Chapter6_3_2_2 6.3 Architectural Components 6.3.2 Interior Partitions 6.3.2.2 Interior Partition Walls, Light Provisions Building Code Provisions |
164 | Retrofit Standard Provisions Typical Causes of Damage |
166 | Damage Examples |
170 | Seismic Mitigation Considerations |
171 | Mitigation Examples |
172 | Mitigation Details |
174 | 16_FEMAE-74-Chapter6_3_2_3 6.3 Architectural Components 6.3.2 Interior Partitions 6.3.2.3 Glazed Partitions Provisions Building Code Provisions Retrofit Standard Provisions |
175 | Typical Causes of Damage |
176 | Damage Examples |
178 | Seismic Mitigation Considerations |
180 | Mitigation Examples |
182 | Mitigation Details |
183 | 17_FEMAE-74-Chapter6_3_3_1 6.3 ARCHITECTURAL COMPONENTS 6.3.3 Interior Veneers 6.3.3.1 Stone, Tile and Masonry Veneer Provisions Building Code Provisions Retrofit Standard Provisions |
184 | Typical causes of damage Damage Examples |
186 | Seismic Mitigation Considerations |
187 | Mitigation Details |
188 | 18_FEMAE-74-Chapter6_3_4_1 6.3 Architectural Components 6.3.4 Ceilings 6.3.4.1 Suspended Lay-in Tile Ceiling Systems Provisions Building Code Provisions Retrofit Standard Provisions |
189 | Typical Causes of Damage |
190 | Damage Examples |
194 | Seismic Mitigation Considerations |
197 | Mitigation Examples |
198 | Mitigation Details |
202 | 19_FEMAE-74-Chapter6_3_4_2 6.3 Architectural Components 6.3.4 Ceilings 6.3.4.2 Ceilings applied Directly to Structure Provisions Building Code Provisions Retrofit Standard Provisions |
203 | Typical Causes of Damage |
204 | Damage Examples |
208 | Seismic Mitigation Considerations |
209 | Mitigation Examples |
211 | Mitigation Details |
213 | 20_FEMAE-74-Chapter6_3_4_3 6.3 Architectural Components 6.3.4 Ceilings 6.3.4.3 Suspended Heavy Ceilings Provisions Building Code Provisions |
214 | Retrofit Standard Provisions Typical Causes of Damage |
215 | Damage Examples |
217 | Seismic Mitigation Considerations |
219 | Mitigation Examples |
220 | Mitigation Details |
223 | 21_FEMAE-74-Chapter6_3_5_1 6.3 Architectural Components 6.3.5 Parapets and Appendages 6.3.5.1 Unreinforced Masonry Parapets Provisions Building Code Provisions Retrofit Standard Provisions Typical Causes of Damage |
224 | Damage Examples |
226 | Seismic Mitigation Considerations Mitigation Examples |
228 | Mitigation Details |
229 | 22_FEMAE-74-Chapter6_3_6_1 6.3 Architectural Components 6.3.6 Canopies, Marquees, and Signs 6.3.6.1 Canopies, Marquees, and Signs Provisions Building Code Provisions Retrofit Standard Provisions Typical Causes of Damage |
230 | Damage Examples |
231 | Seismic Mitigation Considerations Mitigation Details |
232 | 23_FEMAE-74-Chapter6_3_7_1 6.3 Architectural Components 6.3.7 Chimneys and Stacks 6.3.7.1 Unreinforced Masonry Chimney Provisions Building Code Provisions Retrofit Standard Provisions Typical Causes of Damage |
233 | Damage Examples |
235 | Seismic Mitigation Considerations |
236 | Mitigation Examples Mitigation Details |
237 | 24_FEMAE-74-Chapter6_3_8_1 6.3 Architectural Components 6.3.8 Stairways 6.3.8.1 Stairways Provisions Building Code Provisions Retrofit Standard Provisions |
238 | Typical Causes of Damage |
239 | Damage Examples |
243 | Seismic Mitigation Considerations |
244 | Mitigation Details |
247 | 25_FEMAE-74-Chapter6_3_9_1 6.3 Architectural Components 6.3.9 Freestanding Walls or Fences 6.3.9.1 Freestanding Masonry Wall or Fence Typical Causes of Damage |
248 | Damage Examples |
251 | Seismic Mitigation Considerations |
253 | Mitigation Details |
255 | 26_FEMAE-74-Chapter6_4_1_1 6.4 Mechanical, Electrical, and Plumbing Components |
256 | 6.4.1 Mechanical Equipment 6.4.1.1 Boilers, Furnaces, Pumps, and Chillers Provisions Building Code Provisions |
257 | Retrofit Standard Provisions Typical Causes of Damage |
258 | Damage Examples |
259 | Seismic Mitigation Considerations |
260 | Mitigation Examples |
262 | Mitigation Details |
264 | 27_FEMAE-74-Chapter6_4_1_2 6.4 Mechanical, Electrical, and Plumbing Components 6.4.1 Mechanical Equipment 6.4.1.2 General Manufacturing and Process Machinery Provisions Building Code Provisions |
265 | Retrofit Standard Provisions |
266 | Typical Causes of Damage |
267 | Damage Examples |
269 | Seismic Mitigation Considerations |
270 | 28-82.pdf 28_FEMAE-74-Chapter6_4_1_3 6.4 Mechanical, Electrical, and Plumbing Components 6.4.1 Mechanical Equipment 6.4.1.3 HVAC Equipment with Vibration Isolation Provisions Building Code Provisions Retrofit Standard Provisions |
271 | Typical Causes of Damage |
272 | Damage Examples |
274 | Seismic Mitigation Considerations |
276 | Mitigation Examples |
278 | Mitigation Details |
279 | 29_FEMAE-74-Chapter6_4_1_4 6.4 Mechanical, Electrical, and Plumbing Components 6.4.1 Mechanical Equipment 6.4.1.4 HVAC Equipment without External Vibration Isolation Provisions Building Code Provisions Retrofit Standard Provisions |
280 | Typical Causes of Damage Damage Examples |
282 | Seismic Mitigation Considerations |
283 | Mitigation Details |
284 | 30_FEMAE-74-Chapter6_4_1_5 6.4 Mechanical, Electrical, and Plumbing Components 6.4.1 Mechanical Equipment 6.4.1.5 HVAC Equipment Suspended In-Line with Ductwork Provisions Building Code Provisions |
285 | Retrofit Standard Provisions Typical Causes of Damage |
286 | Damage Examples |
288 | Seismic Mitigation Considerations Mitigation Examples |
289 | Mitigation Details |
292 | 31_FEMAE-74-Chapter6_4_1_6 6.4 Mechanical, Electrical, and Plumbing Components 6.4.1 Mechanical Equipment 6.4.1.6 Suspended Equipment Provisions Building Code Provisions Retrofit Standard Provisions Typical Causes of Damage |
293 | Damage Examples |
294 | Seismic Mitigation Considerations |
295 | Mitigation Details |
296 | 32_FEMAE-74-Chapter6_4_2_1 6.4 Mechanical, Electrical, and Plumbing Components 6.4.2 Storage Tanks and Water Heaters 6.4.2.1 Structurally Supported Tanks and Vessels Provisions Building Code Provisions |
297 | Retrofit Standard Provisions Typical Causes of Damage |
298 | Damage Examples |
301 | Seismic Mitigation Considerations |
302 | Mitigation Examples |
304 | Mitigation Details |
305 | 33_FEMAE-74-Chapter6_4_2_2 6.4 Mechanical, Electrical, and Plumbing Components 6.4.2 Storage Tanks and Water Heaters 6.4.2.2 Flat Bottom Tanks and Vessels Provisions Building Code Provisions |
306 | Retrofit Standard Provisions Typical Causes of Damage |
307 | Damage Examples |
310 | Seismic Mitigation Considerations |
311 | Mitigation Examples |
314 | Mitigation Details |
315 | 34_FEMAE-74-Chapter6_4_2_3 6.4 Mechanical, Electrical, and Plumbing Components 6.4.2 Storage Tanks and Water Heaters 6.4.2.3 Compressed Gas Cylinders Provisions Building Code Provisions Retrofit Standard Provisions Typical Causes of Damage |
316 | Damage Examples Seismic Mitigation Considerations |
317 | Mitigation Examples |
320 | Mitigation Details |
321 | 35_FEMAE-74_Chapter6_4_2_4 |
330 | 36_FEMAE-74-Chapter6_4_3_1 6.4 Mechanical, Electrical, and Plumbing Components 6.4.3 Pressure piping 6.4.3.1 Suspended Pressure Piping Provisions Building Code Provisions |
331 | Retrofit Standards Provisions Typical Causes of Damage |
332 | Damage Examples |
335 | Seismic Mitigation Considerations |
336 | Mitigation Examples |
339 | Mitigation Details |
344 | 37_FEMAE-74-Chapter6_4_3_2 6.4 Mechanical, Electrical, and Plumbing Components 6.4.3 Pressure Piping 6.4.3.2 In-Line Valves and Pumps Provisions Building Code Provisions |
345 | Retrofit Standard Provisions Typical Causes of Damage Seismic Mitigation Considerations |
347 | Mitigation Examples |
348 | Mitigation Details |
351 | 38_FEMAE-74-Chapter6_4_3_3 6.4 Mechanical, Electrical, and Plumbing Components 6.4.3 Pressure piping 6.4.3.3 Flexible Connections, Expansion Joints, and Seismic Separations Provisions Building Code Provisions Retrofit Standard Provisions |
352 | Typical Causes of Damage Damage Examples |
353 | Seismic Mitigation Considerations |
354 | Mitigation Examples |
357 | Mitigation Details |
358 | 39_FEMAE-74-Chapter6_4_3_4 6.4 Mechanical, Electrical, and Plumbing Components 6.4.3 Pressure Piping 6.4.3.4 Pipe Risers Provisions Building Code Provisions Retrofit Standard Provisions Typical Causes of Damage |
360 | Damage Examples Seismic Mitigation Considerations |
362 | Mitigation Examples |
365 | Mitigation Details |
369 | 40_FEMAE-74-Chapter6_4_3_5 6.4 Mechanical, Electrical, and Plumbing Components 6.4.3 Pressure Piping 6.4.3.5 Floor-mounted supports Provisions Building Code Provisions |
370 | Retrofit Standard Provisions Typical Causes of Damage |
371 | Damage Examples |
372 | Seismic Mitigation Considerations |
373 | Mitigation Examples |
376 | Mitigation Details |
379 | 41_FEMAE-74-Chapter6_4_3_6 6.4 Mechanical, Electrical, and Plumbing Components 6.4.3 Pressure Piping 6.4.3.6 Roof-Mounted Supports Provisions Building Code Provisions |
380 | Retrofit Standard Provisions Typical Causes of Damage |
381 | Damage Examples |
383 | Seismic Mitigation Considerations |
384 | Mitigation Examples |
385 | Mitigation Details |
387 | 42_FEMAE-74-Chapter6_4_3_7 6.4 Mechanical, Electrical, and Plumbing Components 6.4.3 Pressure Piping 6.4.3.7 Wall-Mounted Supports Provisions Building Code Provisions |
388 | Retrofit Standard Provisions Typical Causes of Damage |
389 | Damage Examples |
390 | Seismic Mitigation Considerations |
391 | Mitigation Examples |
392 | Mitigation Details |
396 | 43_FEMAE-74-Chapter6_4_3_8 6.4 Mechanical, Electrical, and Plumbing Components 6.4.3 Pressure Piping 6.4.3.8 Penetrations Provisions Building Code Provisions Retrofit Standard Provisions |
397 | Typical Causes of Damage |
398 | Damage Examples |
401 | Seismic Mitigation Considerations |
402 | Mitigation Examples |
405 | Mitigation Details |
407 | 44_FEMAE-74-Chapter6_4_4_1 6.4 Mechanical, Electrical, and Plumbing Components 6.4.4 Fire Protection piping 6.4.4.1 Suspended Fire Protection Piping Provisions Building Code Provisions |
408 | Retrofit Standard Provisions Typical Causes of Damage |
410 | Damage Examples |
414 | Seismic Mitigation Considerations |
415 | Mitigation Examples |
417 | Mitigation Details |
418 | 45_FEMAE-74-Chapter6_4_5_1 6.4 Mechanical, Electrical, and Plumbing Components 6.4.5 Fluid Piping, not Fire Protection 6.4.5.1 Hazardous Materials Piping Provisions Building Code Provisions Retrofit Standard Provisions |
419 | Typical Causes of Damage |
420 | Damage Examples |
423 | Seismic Mitigation Considerations |
425 | Mitigation Examples |
430 | Mitigation Details |
431 | 46_FEMAE-74-Chapter6_4_5_2 6.4 Mechanical, Electrical, and Plumbing Components 6.4.5 Fluid Piping, not Fire Protection 6.4.5.2 Nonhazardous Materials Piping Provisions Building Code Provisions |
432 | Retrofit Standard Provisions Typical Causes of Damage |
433 | Damage Examples |
436 | Seismic Mitigation Considerations Mitigation Examples |
439 | 47_FEMAE-74-Chapter6_4_6_1 6.4 Mechanical, Electrical, and Plumbing Components 6.4.6 Ductwork 6.4.6.1 Suspended Ductwork Provisions Building Code Provisions |
440 | Retrofit Standard Provisions Typical Causes of Damage |
441 | Damage Examples |
443 | Seismic Mitigation Considerations |
444 | Mitigation Examples |
447 | Mitigation Details |
449 | 48-82.pdf 48_FEMAE-74-Chapter6_4_6_2 6.4 Mechanical, Electrical, and Plumbing Components 6.4.6 Ductwork 6.4.6.2 Air Diffusers Provisions Building Code Provisions Retrofit Standard Provisions Typical Causes of Damage |
450 | Damage Examples |
451 | Seismic Mitigation Considerations |
452 | Mitigation Details |
453 | 49_FEMAE-74-Chapter6_4_7_1 6.4 Mechanical, Electrical, and Plumbing Components 6.4.7 Electrical and Communications Equipment 6.4.7.1 Control Panels, Motor Control Centers, and Switchgear Provisions Building Code Provisions |
454 | Retrofit Standard Provisions Typical Causes of Damage |
455 | Damage Example |
457 | Seismic Mitigation Considerations Mitigation Examples |
459 | Mitigation Details |
461 | 50_FEMAE-74-Chapter6_4_7_2 6.4 Mechanical, Electrical, and Plumbing Components 6.4.7 Electrical and Communications Equipment 6.4.7.2 Emergency Generators Provisions Building Code Provisions Rehabilitation Code Provisions |
462 | Typical Causes of Damage Seismic Mitigation Considerations |
463 | Mitigation Examples |
465 | Mitigation Details |
466 | 51_FEMAE-74-Chapter6_4_7_3 6.4 Mechanical, Electrical, and Plumbing Components 6.4.7 Electrical and Communications Equipment 6.4.7.3 Transformers Provisions Building Code Provisions |
467 | Retrofit Standard Provisions Typical Causes of Damage |
468 | Damage Examples |
469 | Seismic Mitigation Considerations |
474 | Mitigation Details |
475 | 52_FEMAE-74-Chapter6_4_7_4 6.4 Mechanical, Electrical, and Plumbing Components 6.4.7 Electrical and Communications Equipment 6.4.7.4 Batteries and Battery Racks Provisions Building Code Provisions Retrofit Standard Provisions |
476 | Typical Causes of Damage |
477 | Damage Examples Seismic Mitigation Considerations |
478 | Mitigation Examples |
480 | Mitigation Details |
481 | 53_FEMAE-74-Chapter6_4_7_5 6.4 Mechanical, Electrical, and Plumbing Components 6.4.7 Electrical And Communications Equipment 6.4.7.5 Photovoltaic (PV) Power Systems Provisions Building Code Provisions |
482 | Retrofit Standard Provisions Typical Causes of Damage Seismic Mitigation Considerations |
484 | Mitigation Examples |
488 | Mitigation Details |
490 | 54_FEMAE-74-Chapter6_4_7_6 6.4 Mechanical, Electrical, and Plumbing Components 6.4.7 Electrical and Communications Equipment 6.4.7.6 Communications Antennae Provisions Building Code Provisions Retrofit Standard Provisions |
491 | Typical Causes of Damage |
492 | Damage Examples |
494 | Seismic Mitigation Considerations |
495 | Mitigation Examples |
497 | Mitigation Details |
499 | 55_FEMAE-74-Chapter6_4_8_1 6.4 Mechanical, Electrical, and Plumbing Components 6.4.8 Electrical and Communications Distribution Equipment 6.4.8.1 Electrical Raceways, Conduit, and Cable Trays Provisions Building Code Provisions |
500 | Retrofit Standard Provisions Typical Causes of Damage |
501 | Damage Examples Seismic Mitigation Considerations |
502 | Mitigation Examples |
503 | Mitigation Details |
504 | 56_FEMAE-74-Chapter6_4_8_2 6.4 Mechanical, Electrical, and Plumbing Components 6.4.8 Electrical and Communications Distribution Equipment 6.4.8.2 Electrical Distribution Panels Provisions Building Code Provisions Retrofit Standard Provisions |
505 | Typical Causes of Damage |
506 | Damage Examples Seismic Mitigation Considerations |
507 | Mitigation Examples |
508 | Mitigation Details |
509 | 57_FEMAE-74-Chapter6_4_9_1 6.4 Mechanical, Electrical, and Plumbing Components 6.4.9 Light Fixtures 6.4.9.1 Recessed Light Fixtures Provisions Building Code Provisions |
510 | Retrofit Standard Provisions |
511 | Typical Causes of Damage |
512 | Damage Examples |
516 | Seismic Mitigation Considerations |
517 | Mitigation Examples |
518 | Mitigation Details |
520 | 58_FEMAE-74-Chapter6_4_9_2 6.4 Mechanical, Electrical, and Plumbing Components 6.4.9 Light Fixtures 6.4.9.2 Surface-Mounted lighting Provisions Building Code Provisions |
522 | Retrofit Standard Provisions Typical Causes of Damage |
523 | Damage Examples |
525 | Seismic Mitigation Considerations |
526 | Mitigation Examples |
527 | Mitigation Details |
528 | 59_FEMAE-74-Chapter6_4_9_3 6.4 Mechanical, ElectricaL, and Plumbing Components 6.4.9 Light Fixtures 6.4.9.3 Pendant Light Fixtures Provisions Building Code Provisions Retrofit Standard Provisions |
529 | Typical Causes of Damage Damage Examples |
532 | Seismic Mitigation Considerations |
533 | Mitigation Details |
534 | 60_FEMAE-74-Chapter6_4_9_4 6.4 Mechanical, Electrical, and Plumbing Components 6.4.9 Light Fixtures 6.4.9.4 Heavy Light Fixtures Provisions Building Code Provisions Retrofit Standard Provisions |
535 | Typical Causes of Damage Damage Examples |
536 | Seismic Mitigation Considerations |
537 | Mitigation Examples |
539 | Mitigation Details |
541 | 61-82.pdf 61_FEMAE-74-Chapter6_4_10_1 6.4 Mechanical, Electrical, and Plumbing Components 6.4.10 Elevators and Escalators 6.4.10.1 Hydraulic Elevators Provisions Building Code Provisions |
542 | Retrofit Standard Provisions Typical Causes of Damage |
543 | Seismic Mitigation Considerations |
544 | Mitigation Details |
546 | 62_FEMAE-74-Chapter6_4_10_2 |
564 | 63_FEMAE-74-Chapter6_4_10_3 6.4 Mechanical, Electrical, and Plumbing Components 6.4.10 Elevators and Escalators 6.4.10.3 Escalators Provisions Building Code Provisions Retrofit Standard Provisions |
565 | Typical Causes of Damage |
566 | Damage Examples |
567 | Seismic Mitigation Considerations |
568 | Mitigation Details |
569 | 64_FEMAE-74-Chapter6_4_11_1 6.4 Mechanical, Electrical, and Plumbing Components 6.4.11 Conveyors 6.4.11.1 Conveyors Provisions Building Code Provisions Retrofit Standard Provisions |
570 | Typical Causes of Damage Damage Examples |
573 | Seismic Mitigation Considerations |
574 | Mitigation Details |
575 | 65_FEMAE-74-Chapter6_5_1_1 6.5 Furniture, Fixtures, Equipment and Contents 6.5.1 Storage Racks 6.5.1.1 Light Duty SHelving Provisions Building Code Provisions Retrofit Standard Provisions Typical Causes of Damage |
576 | Damage Examples |
577 | Seismic Mitigation Considerations |
578 | Mitigation Examples |
583 | Mitigation Details |
584 | 66_FEMAE-74-Chapter6_5_1_2 6.5 Furniture, Fixtures, Equipment and Contents 6.5.1 Storage Racks 6.5.1.2 Industrial Storage Racks Provisions Building Code Provisions Retrofit Standard Provisions |
585 | Typical Causes of Damage |
586 | Damage Examples |
590 | Seismic Mitigation Considerations |
591 | Mitigation Examples |
593 | Mitigation Details |
594 | 67_FEMAE-74-Chapter6_5_2_1 6.5 Furniture, Fixtures, Equipment and Contents 6.5.2 Bookcases, Shelving 6.5.2.1 Bookshelves Provisions Building Code Provisions Retrofit Standard Provisions Typical Causes of Damage |
595 | Damage Examples |
597 | Seismic Mitigation Considerations |
599 | Mitigation Details |
601 | 68_FEMAE-74-Chapter6_5_2_2 6.5 Furniture, Fixtures, Equipment and Contents 6.5.2 Bookcases, shelving 6.5.2.2 Library and Other Shelving Provisions Building Code Provisions Retrofit Standard Provisions Typical Causes of Damage |
602 | Damage Examples |
606 | Seismic Mitigation Considerations |
607 | Mitigation Examples |
608 | Mitigation Details |
611 | 69_FEMAE-74-Chapter6_5_3_1 6.5 Furniture, Fixtures, Equipment and Contents 6.5.3 Computer and Communication Equipment 6.5.3.1 Computer Access Floors and Equipment Provisions Building Code Provisions Retrofit Standard Provisions Typical Causes of Damage |
612 | Damage Examples |
615 | Seismic Mitigation Considerations Mitigation Examples |
619 | Mitigation Details |
622 | 70_FEMAE-74-Chapter6_5_3_2 6.5 Furniture, Fixtures, Equipment and Contents 6.5.3 Computer and Communication Equipment 6.5.3.2 Computer and Communication Racks Provisions Building Code Provisions |
623 | Retrofit Standard Provisions Typical Causes of Damage Damage Examples |
624 | Seismic Mitigation Considerations |
625 | Mitigation Examples |
626 | Mitigation Details |
628 | 71_FEMAE-74-Chapter6_5_3_3 6.5 Furniture, Fixtures, Equipment and Contents 6.5.3 Computer and Communication Equipment 6.5.3.3 Desktop Computers and Accessories Typical Causes of Damage Damage Examples |
629 | Seismic Mitigation Considerations |
630 | Mitigation Details |
631 | 72_FEMAE-74-Chapter6_5_3_4 6.5 Furniture, Fixtures, Equipment and Contents 6.5.3 Computer and Communication Equipment 6.5.3.4 Televisions and Video Monitors, Wall-Mounted Provisions Building Code Provisions Retrofit Standard Provisions Typical Causes of Damage |
632 | Existing Condition |
633 | Seismic Mitigation Considerations |
634 | Mitigation Examples |
636 | Mitigation Details |
637 | 73_FEMAE-74-Chapter6_5_4_1 6.5 Furniture, Fixtures, Equipment and Contents 6.5.4 Hazardous Materials Storage 6.5.4.1 Hazardous Materials Storage Provisions Building Code Provisions Retrofit Standard Provisions |
638 | Typical Causes of Damage Damage Examples |
641 | Seismic Mitigation Considerations |
643 | 74_FEMAE-74-Chapter6_5_5_1 6.5 Furniture, Fixtures, Equipment and Contents 6.5.5 Miscellaneous Furniture, Fixtures and Equipment 6.5.5.1 File Cabinets Typical Causes of Damage |
644 | Damage Examples |
646 | Seismic Mitigation Considerations |
647 | Mitigation Details |
650 | 75-82.pdf 75_FEMAE-74-Chapter6_5_5_2 6.5 Furniture, Fixtures, Equipment and Contents 6.5.5 Miscellaneous Furniture, Fixtures and Equipment 6.5.5.2 Demountable Partitions Typical Causes of Damage Damage Examples |
651 | Seismic Mitigation Considerations |
652 | Mitigation Details |
654 | 76_FEMAE-74-Chapter6_5_5_3 6.5 Furniture, Fixtures, Equipment and Contents 6.5.5 Miscellaneous Furniture, Fixtures and Equipment 6.5.5.3 Miscellaneous Furniture and Fixtures Typical Causes of Damage Damage Examples |
656 | Seismic Mitigation Considerations |
657 | Mitigation Examples |
659 | 77_FEMAE-74-Chapter6_5_6_1 6.5 Furniture, Fixtures, Equipment and Contents 6.5.6 Miscellaneous Contents 6.5.6.1 Shelf-Mounted Items Typical Causes of Damage Damage Examples |
660 | Seismic Mitigation Considerations |
661 | Mitigation Examples |
664 | Mitigation Details |
665 | 78_FEMAE-74-Chapter6_5_6_2 6.5 Furniture, Fixtures, Equipment and Contents 6.5.6 Miscellaneous Contents 6.5.6.2 DeskTop, CounterTop Items Typical Causes of Damage Damage Examples |
666 | Seismic Mitigation Considerations |
667 | Mitigation Examples |
668 | Mitigation Details |
670 | 79_FEMAE-74-Chapter6_5_6_3 6.5 Furniture, Fixtures, Equipment and Contents 6.5.6 Miscellaneous Contents 6.5.6.3 Fragile Artwork Typical Causes of Damage Damage Examples |
672 | Seismic Mitigation Considerations |
673 | Mitigation Examples |
676 | Mitigation Details |
677 | 80_FEMAE-74-Chapter6_5_6_4 6.5 Furniture, Fixtures, Equipment and Contents 6.5.6 Miscellaneous Contents 6.5.6.4 Fire Extinguisher and Cabinet Typical Causes of Damage |
678 | Damage Example |
679 | Seismic Mitigation Considerations Mitigation Details |
680 | 81_FEMAE-74-Chapter6_part2 6.6 Installation Notes, Safety Warnings, and additional guidelines 6.6.1 Positive Connections |
681 | 6.6.2 Typical Wall Attachment Details Anchorage to Wood or Metal Stud Partition Walls |
682 | Hardware – Recommended Hardware – Not Recommended |
683 | Anchorage to Concrete or Masonry Walls |
684 | Hardware and Procedures – Recommended |
685 | Hardware and Procedures – Not Recommended 6.6.3 Typical Floor and Ceiling Attachment Details Anchorage to Wood Framing Hardware and Procedures – Recommended |
686 | Hardware and Procedures – Not Recommended Anchorage to Steel Framing Hardware – Recommended Anchorage to Concrete Floor or Roof Slabs Hardware and Procedures – Recommended |
687 | Hardware and Procedures – Not Recommended 6.6.4 Typical Shelf or Countertop Attachment Details Hardware and Procedures – Recommended |
688 | 6.6.5 Purchasing 6.6.6 Patching, Painting, and Corrosion Protection |
689 | 6.6.7 Safety Precautions Procedures – Recommended 6.6.8 Electrical Danger Warnings and guidelines |
691 | 82_FEMAE-74-Chapter7 |
692 | 83_FEMAE-74-AppendixA |
694 | 84_FEMAE-74-AppendixB |
696 | 85_FEMAE-74-AppendixC |
698 | 86_FEMAE-74-AppendixD |
726 | 87_FEMAE-74-AppendixE.pdf |
739 | 83_FEMAE-74-AppendixA |
757 | 84_FEMAE-74-AppendixB |
759 | 85_FEMAE-74-AppendixC |
761 | 86_FEMAE-74-AppendixD |
789 | 87_FEMAE-74-AppendixE |
802 | 88_FEMAE-74-AppendixF |
803 | FEMAE-74_AppendixF_SuspendedAcousticalTileCeiling |
810 | FEMAE-74_AppendixF_MetalStudPartition |
819 | 89_FEMAE-74-AppendixG |
865 | 90_FEMAE-74-AppendixH |
874 | 91_FEMAE-74-AppendixI |
882 | FEMA Project Officers Project Managers |
883 | Project Management Committee |
884 | Project Review Panel |
885 | Additional Reviewers Additional Contributor |