FL FuelGas 07 2007
$48.34
Florida Building Code – Fuel Gas
Published By | Publication Date | Number of Pages |
FL | 2007 | 178 |
This is a fully integrated code based on the 2006 International Fuel Gas Code.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2007 FLORIDA BUILDING CODE – FUEL GAS CODE |
2 | COPYRIGHT© 2008 |
3 | PREFACE |
5 | TABLE OF CONTENTS |
7 | CHAPTER 1 – ADMINISTRATION SECTION 101 (IFGC) GENERAL SECTION 102 (IFGC)APPLICABILITY RESERVED SECTION 103 (IFGC)DEPARTMENT OF INSPECTION RESERVED SECTION 104 (IFGC) DUTIES AND POWERS OF THE CODE OFFICIAL RESERVED SECTION 105 (IFGC) APPROVAL RESERVED SECTION 106 (IFGC) PERMITS RESERVED SECTION 107 (IFGC) INSPECTIONS AND TESTING RESERVED SECTION 108 (IFGC) VIOLATIONS RESERVED SECTION 109 (IFGC) MEANS OF APPEAL RESERVED |
9 | CHAPTER 2 – DEFINITIONS SECTION 201 (IFGC) GENERAL SECTION 202 (IFGC) GENERAL DEFINITIONS |
17 | CHAPTER 3 – GENERAL REGULATIONS SECTION 301 (IFGC) GENERAL |
18 | SECTION 302 (IFGC) STRUCTURAL SAFETY |
19 | SECTION 303 (IFGC) APPLIANCE LOCATION SECTION 304 (IFGS) COMBUSTION, VENTILATION AND DILUTION AIR |
20 | (EQUATION 3-1) (EQUATION 3-2) FIGURE 304.5.3 – ALL AIR FROM INSIDE THE BUILDING(SEE SECTION 304.5.3) |
21 | FIGURE 304.6.1(1) – ALL AIR FROM OUTDOORS—INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC(see Section 304.6.1) FIGURE 304.6.1(2) – ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC(SEE SECTION 304.6.1) FIGURE 304.6.1(3) – ALL AIR FROM OUTDOORS(SEE SECTION 304.6.1) |
22 | FIGURE 304.6.2 – SINGLE COMBUSTION AIR OPENING,ALL AIR FROM THE OUTDOORS(SEE SECTION 304.6.2) SECTION 305 (IFGC) INSTALLATION |
23 | SECTION 306 (IFGC) ACCESS AND SERVICE SPACE |
25 | SECTION 307 (IFGC) CONDENSATE DISPOSAL SECTION 308 (IFGS) CLEARANCE REDUCTION |
26 | TABLE 308.2a – THROUGH k REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTION |
27 | FIGURE 308.2(1) – EXTENT OF PROTECTION NECESSARY TO REDUCE CLEARANCES FROM APPLIANCE OR VENT CONNECTIONS FIGURE 308.2(2) – WALL PROTECTOR CLEARANCE REDUCTION SYSTEM FIGURE 308.2(3) – MASONRY CLEARANCE REDUCTION SYSTEM |
28 | SECTION 309 (IFGC) ELECTRICAL SECTION 310 (IFGS) ELECTRICAL BONDING |
29 | CHAPTER 4 – GAS PIPING INSTALLATIONS SECTION 401 (IFGC) GENERAL SECTION 402 (IFGS) PIPE SIZING |
30 | TABLE 402.2 – APPROXIMATE GAS INPUT FOR TYPICAL APPLIANCES (EQUATION 4-1) (EQUATION 4-2) TABLE 402.4Cr AND Y VALUES FOR NATURAL GAS ANDUNDILUTED PROPANE AT STANDARD CONDITIONS |
31 | TABLE 402.4(1) – SCHEDULE 40 METALLIC PIPE |
32 | TABLE 402.4(2) – SCHEDULE 40 METALLIC PIPE |
33 | TABLE 402.4(3) – SCHEDULE 40 METALLIC PIPE |
34 | TABLE 402.4(4) – SCHEDULE 40 METALLIC PIPE |
35 | TABLE 402.4(5) – SCHEDULE 40 METALLIC PIPE |
36 | TABLE 402.4(6) – SEMIRIGID COPPER TUBING |
37 | TABLE 402.4(7) – SEMIRIGID COPPER TUBING |
38 | TABLE 402.4(8) – SEMIRIGID COPPER TUBING |
39 | TABLE 402.4(9) – SEMIRIGID COPPER TUBING |
40 | TABLE 402.4(10) – SEMIRIGID COPPER TUBING |
41 | TABLE 402.4(11) – SEMIRIGID COPPER TUBING |
42 | TABLE 402.4(12) – SEMIRIGID COPPER TUBING |
43 | TABLE 402.4(13) -CORRUGATED STAINLESS STEEL TUBING (CSST) |
44 | TABLE 402.4(14) -CORRUGATED STAINLESS STEEL TUBING (CSST) |
45 | TABLE 402.4(15) – CORRUGATED STAINLESS STEEL TUBING (CSST) |
46 | TABLE 402.4(16) – CORRUGATED STAINLESS STEEL TUBING (CSST) |
47 | TABLE 402.4(17) – CORRUGATED STAINLESS STEEL TUBING (CSST) |
48 | TABLE 402.4(18) – POLYETHYLENE PLASTIC PIPE |
49 | TABLE 402.4(19) – POLYETHYLENE PLASTIC PIPE |
50 | TABLE 402.4(20) – POLYETHYLENE PLASTIC PIPE |
51 | TABLE 402.4(21) – POLYETHYLENE PLASTIC TUBING TABLE 402.4(22) – POLYETHYLENE PLASTIC TUBING |
52 | TABLE 402.4(23) – SCHEDULE 40 METALLIC PIPE |
53 | TABLE 402.4(24) – SCHEDULE 40 METALLIC PIPE |
54 | TABLE 402.4(25) – SCHEDULE 40 METALLIC PIPE |
55 | TABLE 402.4(26) – SCHEDULE 40 METALLIC PIPE |
56 | TABLE 402.4(27) – SEMIRIGID COPPER TUBING |
57 | TABLE 402.4(28) – SEMIRIGID COPPER TUBING |
58 | TABLE 402.4(29) – SEMIRIGID COPPER TUBING |
59 | TABLE 402.4(30) – CORRUGATED STAINLESS STEEL TUBING (CSST) |
60 | TABLE 402.4(31) – CORRUGATED STAINLESS STEEL TUBING (CSST) |
61 | TABLE 402.4(32) – CORRUGATED STAINLESS STEEL TUBING (CSST) |
62 | TABLE 402.4(33) – POLYETHYLENE PLASTIC PIPE |
63 | TABLE 402.4(34) – POLYETHYLENE PLASTIC PIPE |
64 | TABLE 402.4(35) -POLYETHYLENE PLASTIC TUBING SECTION 403 (IFGS) PIPING MATERIALS |
66 | TABLE 403.9.2 SPECIFICATIONS FOR THREADING METALLIC PIPE |
67 | SECTION 404 (IFGC) PIPING SYSTEM INSTALLATION |
68 | SECTION 405 (IFGS) PIPING BENDS AND CHANGES IN DIRECTION SECTION 406 (IFGS) INSPECTION, TESTING AND PURGING |
70 | TABLE 406.7.1 LENGTH OF PIPING REQUIRING PURGING WITH INERT GAS FOR SERVICING OR MODIFICATION TABLE 406.7.2 LENGTH OF PIPING REQUIRING PURGING WITH INERT GAS BEFORE PLACING IN OPERATION SECTION 407 (IFGC) PIPING SUPPORT SECTION 408 (IFGC) DRIPS AND SLOPED PIPING SECTION 409 (IFGC) SHUTOFF VALVES |
71 | TABLE 409.1.1 MANUAL GAS VALVE STANDARDS SECTION 410 (IFGC) FLOW CONTROLS |
72 | SECTION 411 (IFGC) APPLIANCE AND MANUFACTURED HOME CONNECTIONS SECTION 412 (IFGC) LIQUEFIED PETROLEUM GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES |
73 | SECTION 413 (IFGC) COMPRESSED NATURAL GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES |
75 | [F] TABLE 413.9.2.3 SEPARATION DISTANCE FOR ATMOSPHERIC VENTING OF CNG SECTION 414 (IFGC) SUPPLEMENTAL AND STANDBY GAS SUPPLY SECTION 415 (IFGS) PIPING SUPPORT INTERVALS TABLE 415.1 SUPPORT OF PIPING SECTION 416 (IFGS) OVER PRESSURE PROTECTION DEVICES |
77 | CHAPTER 5 – CHIMNEYS AND VENTS SECTION 501 (IFGC) GENERAL |
78 | SECTION 502 (IFGC) VENTS |
79 | SECTION 503 (IFGS) VENTING OF APPLIANCES |
80 | TABLE 503.4 TYPE OF VENTING SYSTEM TO BE USED |
81 | FIGURE 503.5.4 TYPICAL TERMINATION LOCATIONS FOR CHIMNEYS AND SINGLE-WALL METAL PIPES SERVING RESIDENTIAL-TYPE AND LOW-HEAT EQUIPMENT |
83 | FIGURE 503.6.4 TERMINATION LOCATIONS FOR GAS VENTS WITH LISTED CAPS 12 INCHES OR LESS IN SIZE AT LEAST 8 FEETFROM A VERTICAL WALL FIGURE 503.6.10.1 PLAN VIEW OF PRACTICAL SEPARATION METHOD FOR MULTISTORY GAS VENTING |
85 | TABLE 503.7.7a CLEARANCES FOR CONNECTORS |
86 | TABLE 503.10.2.4 MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES TABLE 503.10.2.5 MINIMUM THICKNESS FOR STEEL VENT CONNECTORS FORMEDIUM-HEAT APPLIANCES AND COMMERCIAL ANDINDUSTRIAL INCINERATORS VENT CONNECTOR SIZE |
88 | SECTION 504 (IFGS) SIZING OF CATEGORY I APPLIANCE VENTING SYSTEMS |
90 | TABLE 504.2(1) – TYPE B DOUBLE-WALL GAS VENT |
91 | TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT |
92 | TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT |
93 | TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT |
94 | TABLE 504.2(2) – TYPE B DOUBLE-WALL GAS VENT |
95 | TABLE 504.2(2)—continued TYPE B DOUBLE-WALL GAS VENT |
96 | TABLE 504.2(3) – MASONRY CHIMNEY |
97 | TABLE 504.2(3)—continued MASONRY CHIMNEY |
98 | TABLE 504.2(4) – MASONRY CHIMNEY |
99 | TABLE 504.2(4)—continued MASONRY CHIMNEY |
100 | TABLE 504.2(5) – SINGLE-WALL METAL PIPE OR TYPE BASBESTOS CEMENT VENT |
101 | TABLE 504.2(6) – EXTERIOR MASONRY CHIMNEY |
103 | TABLE 504.3.2 – MAXIMUM VENT CONNECTOR LENGTH |
105 | SECTION 505 (IFGC)DIRECT-VENT, INTEGRAL VENT,MECHANICAL VENT AND VENTILATION/EXHAUST HOOD VENTING SECTION 506 (IFGC)FACTORY-BUILT CHIMNEYS |
106 | TABLE 504.3(1) – TYPE B DOUBLE-WALL VENT |
107 | TABLE 504.3(1)—continuedTYPE B DOUBLE-WALL VENT |
108 | TABLE 504.3(2) – TYPE B DOUBLE-WALL VENT |
109 | TABLE 504.3(3) – MASONRY CHIMNEY |
110 | TABLE 504.3(4) – MASONRY CHIMNEY |
111 | TABLE 504.3(5) – SINGLE-WALL METAL PIPE OR TYPE ASBESTOS CEMENT VENT |
112 | TABLE 504.3(6a) – EXTERIOR MASONRY CHIMNEY TABLE 504.3(6b) – EXTERIOR MASONRY CHIMNEY TABLE 504.3(6b) – EXTERIOR MASONRY CHIMNEY—continued |
113 | TABLE 504.3(7a)EXTERIOR MASONRY CHIMNEY TABLE 504.3(7b)EXTERIOR MASONRY CHIMNEY TABLE 504.3(7b)EXTERIOR MASONRY CHIMNEY—continued |
115 | CHAPTER 6 – SPECIFIC APPLIANCES SECTION 601 (IFGC) GENERAL SECTION 602 (IFGC) DECORATIVE APPLIANCES FOR INSTALLATION IN FIREPLACES SECTION 603 (IFGC) LOG LIGHTERS SECTION 604 (IFGC) VENTED GAS FIREPLACES(DECORATIVE APPLIANCES) SECTION 605 (IFGC) VENTED GAS FIREPLACE HEATERS SECTION 606 (IFGC) INCINERATORS AND CREMATORIES SECTION 607 (IFGC) COMMERCIAL-INDUSTRIAL INCINERATORS SECTION 608 (IFGC) VENTED WALL FURNACES SECTION 609 (IFGC) FLOOR FURNACES |
116 | SECTION 610 (IFGC) DUCT FURNACES SECTION 611 (IFGC) NON RECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS |
117 | SECTION 612 (IFGC) RECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS SECTION 613 (IFGC) CLOTHES DRYERS SECTION 614 (IFGC) CLOTHES DRYER EXHAUST |
118 | SECTION 615 (IFGC) SAUNA HEATERS RESERVED SECTION 616 (IFGC) ENGINE AND GAS TURBINE POWERED EQUIPMENT SECTION 617 (IFGC) POOL AND SPA HEATERS SECTION 618 (IFGC) FORCED-AIR WARM-AIR FURNACES |
119 | SECTION 619 (IFGC) CONVERSION BURNERS SECTION 620 (IFGC) UNIT HEATERS SECTION 621 (IFGC) UNVENTED ROOM HEATERS |
120 | SECTION 622 (IFGC) VENTED ROOM HEATERS SECTION 623 (IFGC) COOKING APPLIANCES SECTION 624 (IFGC) WATER HEATERS SECTION 625 (IFGC) REFRIGERATORS SECTION 626 (IFGC) GAS-FIRED TOILETS SECTION 627 (IFGC) AIR-CONDITIONING EQUIPMENT |
121 | SECTION 628 (IFGC) ILLUMINATING APPLIANCES SECTION 629 (IFGC) SMALL CERAMIC KILNS |
122 | SECTION 630 (IFGC) INFRARED RADIANT HEATERS SECTION 631 (IFGC) BOILERS SECTION 632 (IFGC) EQUIPMENT INSTALLED IN EXISTING UNLISTED BOILERS SECTION 633 (IFGC) STATIONARY FUEL-CELL POWER SYSTEMS SECTION 634 (IFGS) CHIMNEY DAMPER OPENING AREA TABLE 634.1 FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING FLUE GASES FROM UNLISTED DECORATIVE APPLIANCES FOR INSTALLATION IN VENTED FIREPLACES SECTION 635 (IFGC) GASEOUS HYDROGEN SYSTEMS |
123 | CHAPTER 7 – GASEOUS HYDROGEN SYSTEMS SECTION 701 (IFGC) GENERAL SECTION 702 (IFGC) GENERAL DEFINITIONS SECTION 703 (IFGC) GENERAL REQUIREMENTS |
124 | SECTION 704 (IFGC) PIPING, USE AND HANDLING |
125 | SECTION 705 (IFGC) TESTING OF HYDROGEN PIPING SYSTEMS |
126 | SECTION 706 (IFGC) LOCATION OF GASEOUS HYDROGEN SYSTEMS |
127 | SECTION 707 (IFGC) OPERATION AND MAINTENANCE OFGASEOUS HYDROGEN SYSTEMS SECTION 708 (IFGC) DESIGN OF LIQUEFIED HYDROGEN SYSTEMS ASSOCIATED WITH HYDROGEN VAPORIZATION OPERATIONS |
129 | IFGC/IFGS CHAPTER 8 – REFERENCED STANDARDS ANSI |
130 | ASME ASTM AWWA CGA |
131 | CSA DOTn FLORIDA CODES MSS |
132 | NFPA UL |
133 | APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING |
134 | TABLE A.2.2 – EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES |
135 | TABLE A.2.2—continued EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES |
136 | TABLE A.2.4 – MULTIPLIERS TO BE USED WITH TABLES 402.4(1)THROUGH 402.4(22) WHERE THE SPECIFIC GRAVITY OF THE GAS IS OTHER THAN 0.60 |
138 | TABLE A.3.4 – THOUSANDS OF Btu/h (MBH) OF NATURAL GAS PER 100 FEET OF PIPE ATVARIOUS PRESSURE DROPS AND PIPE DIAMETERS |
139 | TABLE A.5.1 – SCHEDULE 40 STEEL PIPE STANDARD SIZES TABLE A.5.2 – COPPER TUBE STANDARD SIZES |
140 | FIGURE A.6 (a) – CAPACITY OF NATURAL GAS PIPING, LOW PRESSURE (0.60 WC) FIGURE A.6 (b) – CAPACITY OF NATURAL GAS PIPING, HIGH PRESSURE (1.5 psi and above) |
141 | FIGURE A.7.1 – PIPING PLAN SHOWING A STEEL PIPING SYSTEM |
142 | FIGURE A.7.2 – PIPING PLAN SHOWING A CSST SYSTEM FIGURE A.7.3 – PIPING PLAN SHOWING A COPPER TUBING SYSTEM |
143 | FIGURE A.7.4 – PIPING PLAN SHOWING A MODIFICATIONTO EXISTING PIPING SYSTEM |
145 | APPENDIX B (IFGS) SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES, AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS EXAMPLES USING SINGLE APPLIANCE VENTING TABLES FIGURE B-1 – TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A TYPE B DOUBLE-WALL VENT FIGURE B-2 – TYPE B DOUBLE-WALL VENT SYSTEM SERVINGA SINGLE APPLIANCE WITH A SINGLE-WALLMETAL VENT CONNECTOR |
146 | FIGURE B-3 – VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A MASONRY CHIMNEY OF TYPE B DOUBLE-WALL VENT CONNECTOR FIGURE B-4 – VENT SYSTEM SERVING A SINGLE APPLIANCE USING A MASONRY CHIMNEY AND ASINGLE-WALL METAL VENT CONNECTOR FIGURE B-5 – ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING A SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE FIGURE B-6 – VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND TYPE B DOUBLE-WALL VENT CONNECTOR |
147 | FIGURE B-7 – VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND SINGLE-WALL METAL VENT CONNECTORS FIGURE B-8 – MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT CONNECTOR FIGURE B-9 – MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH SINGLE-WALL METAL VENT CONNECTORS FIGURE B-10 – ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING TWO OR MORE DRAFT-HOOD-EQUIPPED APPLIANCES |
148 | FIGURE B-11 – USE OF MANIFOLD COMMON VENT CONNECTOR FIGURE B-12 – USE OF OFFSET COMMON VENT FIGURE B-13 – MULTISTORY GAS VENT DESIGN PROCEDURE FOR EACH SEGMENT OF SYSTEM FIGURE B-14 – MULTISTORY VENT SYSTEMS |
149 | FIGURE B-15 – (EXAMPLE 1)SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE FIGURE B-16 – (EXAMPLE 2)SINGLE FAN-ASSISTED APPLIANCE |
150 | FIGURE B-17 – (EXAMPLE 4)COMMON VENTING TWO DRAFTHOOD-EQUIPPED APPLIANCES FIGURE B-18 – (EXAMPLE 5A)COMMON VENTING A DRAFT HOOD WITH A FAN-ASSISTEDFURNACE INTO A TYPE B DOUBLE-WALL COMMON VENT |
152 | TABLE B-1 – MASONRY CHIMNEY LINER DIMENSIONS WITH CIRCULAR EQUIVALENTSa |
153 | FIGURE B-19 |
155 | APPENDIX C (IFGS) EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS |
157 | APPENDIX D (IFGS) RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION |
159 | INDEX |
163 | 2007 FLORIDA BUILDING CODE CHAPTER 1 BUILDING |
165 | CHAPTER 1 ADMINISTRATION SECTION 101 GENERAL SECTION 102 APPLICABILITY |
167 | SECTION 103 DEPARTMENT OF BUILDING SAFETY RESERVED SECTION 104 DUTIES AND POWERS OF THE BUILDING OFFICIAL SECTION 105 PERMITS |
171 | SECTION 106 CONSTRUCTION DOCUMENTS |
174 | SECTION 107 TEMPORARY STRUCTURES AND USES SECTION 108 FEES |
175 | SECTION 109 INSPECTIONS |
177 | SECTION 110 CERTIFICATES OF OCCUPANCY AND COMPLETION |
178 | SECTION 111 SERVICE UTILITIES SECTION 112 BOARD OF APPEALS RESERVED SECTION 113 VIOLATIONS RESERVED SECTION 114 STOP WORK ORDER SECTION 115 UNSAFE STRUCTURES AND EQUIPMENT RESERVED |