Shopping Cart

No products in the cart.

FL FuelGas 07 2007

$48.34

Florida Building Code – Fuel Gas

Published By Publication Date Number of Pages
FL 2007 178
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This is a fully integrated code based on the 2006 International Fuel Gas Code.

PDF Catalog

PDF Pages PDF Title
1 2007 FLORIDA BUILDING CODE – FUEL GAS CODE
2 COPYRIGHT© 2008
3 PREFACE
5 TABLE OF CONTENTS
7 CHAPTER 1 –
ADMINISTRATION
SECTION 101 (IFGC) GENERAL
SECTION 102 (IFGC)APPLICABILITY RESERVED
SECTION 103 (IFGC)DEPARTMENT OF INSPECTION RESERVED
SECTION 104 (IFGC) DUTIES AND POWERS OF THE CODE OFFICIAL RESERVED
SECTION 105 (IFGC) APPROVAL RESERVED
SECTION 106 (IFGC) PERMITS RESERVED
SECTION 107 (IFGC) INSPECTIONS AND TESTING RESERVED
SECTION 108 (IFGC) VIOLATIONS RESERVED
SECTION 109 (IFGC) MEANS OF APPEAL RESERVED
9 CHAPTER 2 – DEFINITIONS
SECTION 201 (IFGC) GENERAL
SECTION 202 (IFGC) GENERAL DEFINITIONS
17 CHAPTER 3 – GENERAL REGULATIONS
SECTION 301 (IFGC) GENERAL
18 SECTION 302 (IFGC) STRUCTURAL SAFETY
19 SECTION 303 (IFGC) APPLIANCE LOCATION
SECTION 304 (IFGS) COMBUSTION, VENTILATION AND DILUTION AIR
20 (EQUATION 3-1)
(EQUATION 3-2)
FIGURE 304.5.3 – ALL AIR FROM INSIDE THE BUILDING(SEE SECTION 304.5.3)
21 FIGURE 304.6.1(1) – ALL AIR FROM OUTDOORS—INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC(see Section 304.6.1)
FIGURE 304.6.1(2) – ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC(SEE SECTION 304.6.1)
FIGURE 304.6.1(3) – ALL AIR FROM OUTDOORS(SEE SECTION 304.6.1)
22 FIGURE 304.6.2 – SINGLE COMBUSTION AIR OPENING,ALL AIR FROM THE OUTDOORS(SEE SECTION 304.6.2)
SECTION 305 (IFGC) INSTALLATION
23 SECTION 306 (IFGC) ACCESS AND SERVICE SPACE
25 SECTION 307 (IFGC) CONDENSATE DISPOSAL
SECTION 308 (IFGS) CLEARANCE REDUCTION
26 TABLE 308.2a – THROUGH k REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTION
27 FIGURE 308.2(1) – EXTENT OF PROTECTION NECESSARY TO REDUCE CLEARANCES FROM APPLIANCE OR VENT CONNECTIONS
FIGURE 308.2(2) – WALL PROTECTOR CLEARANCE REDUCTION SYSTEM
FIGURE 308.2(3) – MASONRY CLEARANCE REDUCTION SYSTEM
28 SECTION 309 (IFGC) ELECTRICAL
SECTION 310 (IFGS) ELECTRICAL BONDING
29 CHAPTER 4 – GAS PIPING INSTALLATIONS
SECTION 401 (IFGC) GENERAL
SECTION 402 (IFGS) PIPE SIZING
30 TABLE 402.2 – APPROXIMATE GAS INPUT FOR TYPICAL APPLIANCES
(EQUATION 4-1)
(EQUATION 4-2)
TABLE 402.4Cr AND Y VALUES FOR NATURAL GAS ANDUNDILUTED PROPANE AT STANDARD CONDITIONS
31 TABLE 402.4(1) – SCHEDULE 40 METALLIC PIPE
32 TABLE 402.4(2) – SCHEDULE 40 METALLIC PIPE
33 TABLE 402.4(3) – SCHEDULE 40 METALLIC PIPE
34 TABLE 402.4(4) – SCHEDULE 40 METALLIC PIPE
35 TABLE 402.4(5) – SCHEDULE 40 METALLIC PIPE
36 TABLE 402.4(6) – SEMIRIGID COPPER TUBING
37 TABLE 402.4(7) – SEMIRIGID COPPER TUBING
38 TABLE 402.4(8) – SEMIRIGID COPPER TUBING
39 TABLE 402.4(9) – SEMIRIGID COPPER TUBING
40 TABLE 402.4(10) – SEMIRIGID COPPER TUBING
41 TABLE 402.4(11) – SEMIRIGID COPPER TUBING
42 TABLE 402.4(12) – SEMIRIGID COPPER TUBING
43 TABLE 402.4(13) -CORRUGATED STAINLESS STEEL TUBING (CSST)
44 TABLE 402.4(14) -CORRUGATED STAINLESS STEEL TUBING (CSST)
45 TABLE 402.4(15) – CORRUGATED STAINLESS STEEL TUBING (CSST)
46 TABLE 402.4(16) – CORRUGATED STAINLESS STEEL TUBING (CSST)
47 TABLE 402.4(17) – CORRUGATED STAINLESS STEEL TUBING (CSST)
48 TABLE 402.4(18) – POLYETHYLENE PLASTIC PIPE
49 TABLE 402.4(19) – POLYETHYLENE PLASTIC PIPE
50 TABLE 402.4(20) – POLYETHYLENE PLASTIC PIPE
51 TABLE 402.4(21) – POLYETHYLENE PLASTIC TUBING
TABLE 402.4(22) – POLYETHYLENE PLASTIC TUBING
52 TABLE 402.4(23) – SCHEDULE 40 METALLIC PIPE
53 TABLE 402.4(24) – SCHEDULE 40 METALLIC PIPE
54 TABLE 402.4(25) – SCHEDULE 40 METALLIC PIPE
55 TABLE 402.4(26) – SCHEDULE 40 METALLIC PIPE
56 TABLE 402.4(27) – SEMIRIGID COPPER TUBING
57 TABLE 402.4(28) – SEMIRIGID COPPER TUBING
58 TABLE 402.4(29) – SEMIRIGID COPPER TUBING
59 TABLE 402.4(30) – CORRUGATED STAINLESS STEEL TUBING (CSST)
60 TABLE 402.4(31) – CORRUGATED STAINLESS STEEL TUBING (CSST)
61 TABLE 402.4(32) – CORRUGATED STAINLESS STEEL TUBING (CSST)
62 TABLE 402.4(33) – POLYETHYLENE PLASTIC PIPE
63 TABLE 402.4(34) – POLYETHYLENE PLASTIC PIPE
64 TABLE 402.4(35) -POLYETHYLENE PLASTIC TUBING
SECTION 403 (IFGS) PIPING MATERIALS
66 TABLE 403.9.2 SPECIFICATIONS FOR THREADING METALLIC PIPE
67 SECTION 404 (IFGC) PIPING SYSTEM INSTALLATION
68 SECTION 405 (IFGS) PIPING BENDS AND CHANGES IN DIRECTION
SECTION 406 (IFGS) INSPECTION, TESTING AND PURGING
70 TABLE 406.7.1 LENGTH OF PIPING REQUIRING PURGING WITH INERT GAS FOR SERVICING OR MODIFICATION
TABLE 406.7.2 LENGTH OF PIPING REQUIRING PURGING WITH INERT GAS BEFORE PLACING IN OPERATION
SECTION 407 (IFGC) PIPING SUPPORT
SECTION 408 (IFGC) DRIPS AND SLOPED PIPING
SECTION 409 (IFGC) SHUTOFF VALVES
71 TABLE 409.1.1 MANUAL GAS VALVE STANDARDS
SECTION 410 (IFGC) FLOW CONTROLS
72 SECTION 411 (IFGC) APPLIANCE AND MANUFACTURED HOME CONNECTIONS
SECTION 412 (IFGC) LIQUEFIED PETROLEUM GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES
73 SECTION 413 (IFGC) COMPRESSED NATURAL GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES
75 [F] TABLE 413.9.2.3 SEPARATION DISTANCE FOR ATMOSPHERIC VENTING OF CNG
SECTION 414 (IFGC) SUPPLEMENTAL AND STANDBY GAS SUPPLY
SECTION 415 (IFGS) PIPING SUPPORT INTERVALS
TABLE 415.1 SUPPORT OF PIPING
SECTION 416 (IFGS) OVER PRESSURE PROTECTION DEVICES
77 CHAPTER 5 – CHIMNEYS AND VENTS
SECTION 501 (IFGC) GENERAL
78 SECTION 502 (IFGC) VENTS
79 SECTION 503 (IFGS) VENTING OF APPLIANCES
80 TABLE 503.4 TYPE OF VENTING SYSTEM TO BE USED
81 FIGURE 503.5.4 TYPICAL TERMINATION LOCATIONS FOR CHIMNEYS AND SINGLE-WALL METAL PIPES SERVING RESIDENTIAL-TYPE AND LOW-HEAT EQUIPMENT
83 FIGURE 503.6.4 TERMINATION LOCATIONS FOR GAS VENTS WITH LISTED CAPS 12 INCHES OR LESS IN SIZE AT LEAST 8 FEETFROM A VERTICAL WALL
FIGURE 503.6.10.1 PLAN VIEW OF PRACTICAL SEPARATION METHOD FOR MULTISTORY GAS VENTING
85 TABLE 503.7.7a CLEARANCES FOR CONNECTORS
86 TABLE 503.10.2.4 MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES
TABLE 503.10.2.5 MINIMUM THICKNESS FOR STEEL VENT CONNECTORS FORMEDIUM-HEAT APPLIANCES AND COMMERCIAL ANDINDUSTRIAL INCINERATORS VENT CONNECTOR SIZE
88 SECTION 504 (IFGS) SIZING OF CATEGORY I APPLIANCE VENTING SYSTEMS
90 TABLE 504.2(1) – TYPE B DOUBLE-WALL GAS VENT
91 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
92 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
93 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
94 TABLE 504.2(2) – TYPE B DOUBLE-WALL GAS VENT
95 TABLE 504.2(2)—continued TYPE B DOUBLE-WALL GAS VENT
96 TABLE 504.2(3) – MASONRY CHIMNEY
97 TABLE 504.2(3)—continued MASONRY CHIMNEY
98 TABLE 504.2(4) – MASONRY CHIMNEY
99 TABLE 504.2(4)—continued MASONRY CHIMNEY
100 TABLE 504.2(5) – SINGLE-WALL METAL PIPE OR TYPE BASBESTOS CEMENT VENT
101 TABLE 504.2(6) – EXTERIOR MASONRY CHIMNEY
103 TABLE 504.3.2 – MAXIMUM VENT CONNECTOR LENGTH
105 SECTION 505 (IFGC)DIRECT-VENT, INTEGRAL VENT,MECHANICAL VENT AND VENTILATION/EXHAUST HOOD VENTING
SECTION 506 (IFGC)FACTORY-BUILT CHIMNEYS
106 TABLE 504.3(1) – TYPE B DOUBLE-WALL VENT
107 TABLE 504.3(1)—continuedTYPE B DOUBLE-WALL VENT
108 TABLE 504.3(2) – TYPE B DOUBLE-WALL VENT
109 TABLE 504.3(3) – MASONRY CHIMNEY
110 TABLE 504.3(4) – MASONRY CHIMNEY
111 TABLE 504.3(5) – SINGLE-WALL METAL PIPE OR TYPE ASBESTOS CEMENT VENT
112 TABLE 504.3(6a) – EXTERIOR MASONRY CHIMNEY
TABLE 504.3(6b) – EXTERIOR MASONRY CHIMNEY
TABLE 504.3(6b) – EXTERIOR MASONRY CHIMNEY—continued
113 TABLE 504.3(7a)EXTERIOR MASONRY CHIMNEY
TABLE 504.3(7b)EXTERIOR MASONRY CHIMNEY
TABLE 504.3(7b)EXTERIOR MASONRY CHIMNEY—continued
115 CHAPTER 6 – SPECIFIC APPLIANCES
SECTION 601 (IFGC) GENERAL
SECTION 602 (IFGC) DECORATIVE APPLIANCES FOR INSTALLATION IN FIREPLACES
SECTION 603 (IFGC) LOG LIGHTERS
SECTION 604 (IFGC) VENTED GAS FIREPLACES(DECORATIVE APPLIANCES)
SECTION 605 (IFGC) VENTED GAS FIREPLACE HEATERS
SECTION 606 (IFGC) INCINERATORS AND CREMATORIES
SECTION 607 (IFGC) COMMERCIAL-INDUSTRIAL INCINERATORS
SECTION 608 (IFGC) VENTED WALL FURNACES
SECTION 609 (IFGC) FLOOR FURNACES
116 SECTION 610 (IFGC) DUCT FURNACES
SECTION 611 (IFGC) NON RECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS
117 SECTION 612 (IFGC) RECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS
SECTION 613 (IFGC) CLOTHES DRYERS
SECTION 614 (IFGC) CLOTHES DRYER EXHAUST
118 SECTION 615 (IFGC) SAUNA HEATERS RESERVED
SECTION 616 (IFGC) ENGINE AND GAS TURBINE POWERED EQUIPMENT
SECTION 617 (IFGC) POOL AND SPA HEATERS
SECTION 618 (IFGC) FORCED-AIR WARM-AIR FURNACES
119 SECTION 619 (IFGC) CONVERSION BURNERS
SECTION 620 (IFGC) UNIT HEATERS
SECTION 621 (IFGC) UNVENTED ROOM HEATERS
120 SECTION 622 (IFGC) VENTED ROOM HEATERS
SECTION 623 (IFGC) COOKING APPLIANCES
SECTION 624 (IFGC) WATER HEATERS
SECTION 625 (IFGC) REFRIGERATORS
SECTION 626 (IFGC) GAS-FIRED TOILETS
SECTION 627 (IFGC) AIR-CONDITIONING EQUIPMENT
121 SECTION 628 (IFGC) ILLUMINATING APPLIANCES
SECTION 629 (IFGC) SMALL CERAMIC KILNS
122 SECTION 630 (IFGC) INFRARED RADIANT HEATERS
SECTION 631 (IFGC) BOILERS
SECTION 632 (IFGC) EQUIPMENT INSTALLED IN EXISTING UNLISTED BOILERS
SECTION 633 (IFGC) STATIONARY FUEL-CELL POWER SYSTEMS
SECTION 634 (IFGS) CHIMNEY DAMPER OPENING AREA
TABLE 634.1 FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING FLUE GASES FROM UNLISTED DECORATIVE APPLIANCES FOR INSTALLATION IN VENTED FIREPLACES
SECTION 635 (IFGC) GASEOUS HYDROGEN SYSTEMS
123 CHAPTER 7 – GASEOUS HYDROGEN SYSTEMS
SECTION 701 (IFGC) GENERAL
SECTION 702 (IFGC) GENERAL DEFINITIONS
SECTION 703 (IFGC) GENERAL REQUIREMENTS
124 SECTION 704 (IFGC) PIPING, USE AND HANDLING
125 SECTION 705 (IFGC) TESTING OF HYDROGEN PIPING SYSTEMS
126 SECTION 706 (IFGC) LOCATION OF GASEOUS HYDROGEN SYSTEMS
127 SECTION 707 (IFGC) OPERATION AND MAINTENANCE OFGASEOUS HYDROGEN SYSTEMS
SECTION 708 (IFGC) DESIGN OF LIQUEFIED HYDROGEN SYSTEMS ASSOCIATED WITH HYDROGEN VAPORIZATION OPERATIONS
129 IFGC/IFGS CHAPTER 8 –
REFERENCED STANDARDS
ANSI
130 ASME
ASTM
AWWA
CGA
131 CSA
DOTn
FLORIDA CODES
MSS
132 NFPA
UL
133 APPENDIX A (IFGS)
SIZING AND CAPACITIES OF GAS PIPING
134 TABLE A.2.2 – EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
135 TABLE A.2.2—continued EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
136 TABLE A.2.4 – MULTIPLIERS TO BE USED WITH TABLES 402.4(1)THROUGH 402.4(22) WHERE THE SPECIFIC GRAVITY OF THE GAS IS OTHER THAN 0.60
138 TABLE A.3.4 – THOUSANDS OF Btu/h (MBH) OF NATURAL GAS PER 100 FEET OF PIPE ATVARIOUS PRESSURE DROPS AND PIPE DIAMETERS
139 TABLE A.5.1 – SCHEDULE 40 STEEL PIPE STANDARD SIZES
TABLE A.5.2 – COPPER TUBE STANDARD SIZES
140 FIGURE A.6 (a) – CAPACITY OF NATURAL GAS PIPING, LOW PRESSURE (0.60 WC)
FIGURE A.6 (b) – CAPACITY OF NATURAL GAS PIPING, HIGH PRESSURE (1.5 psi and above)
141 FIGURE A.7.1 – PIPING PLAN SHOWING A STEEL PIPING SYSTEM
142 FIGURE A.7.2 – PIPING PLAN SHOWING A CSST SYSTEM
FIGURE A.7.3 – PIPING PLAN SHOWING A COPPER TUBING SYSTEM
143 FIGURE A.7.4 – PIPING PLAN SHOWING A MODIFICATIONTO EXISTING PIPING SYSTEM
145 APPENDIX B (IFGS)
SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED
WITH DRAFT HOODS, CATEGORY I APPLIANCES, AND
APPLIANCES LISTED FOR USE WITH TYPE B VENTS
EXAMPLES USING SINGLE APPLIANCE VENTING TABLES
FIGURE B-1 – TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A TYPE B DOUBLE-WALL VENT
FIGURE B-2 – TYPE B DOUBLE-WALL VENT SYSTEM SERVINGA SINGLE APPLIANCE WITH A SINGLE-WALLMETAL VENT CONNECTOR
146 FIGURE B-3 – VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A MASONRY CHIMNEY OF TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-4 – VENT SYSTEM SERVING A SINGLE APPLIANCE USING A MASONRY CHIMNEY AND ASINGLE-WALL METAL VENT CONNECTOR
FIGURE B-5 – ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING A SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-6 – VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND TYPE B DOUBLE-WALL VENT CONNECTOR
147 FIGURE B-7 – VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-8 – MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-9 – MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-10 – ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING TWO OR MORE DRAFT-HOOD-EQUIPPED APPLIANCES
148 FIGURE B-11 – USE OF MANIFOLD COMMON VENT CONNECTOR
FIGURE B-12 – USE OF OFFSET COMMON VENT
FIGURE B-13 – MULTISTORY GAS VENT DESIGN PROCEDURE FOR EACH SEGMENT OF SYSTEM
FIGURE B-14 – MULTISTORY VENT SYSTEMS
149 FIGURE B-15 – (EXAMPLE 1)SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-16 – (EXAMPLE 2)SINGLE FAN-ASSISTED APPLIANCE
150 FIGURE B-17 – (EXAMPLE 4)COMMON VENTING TWO DRAFTHOOD-EQUIPPED APPLIANCES
FIGURE B-18 – (EXAMPLE 5A)COMMON VENTING A DRAFT HOOD WITH A FAN-ASSISTEDFURNACE INTO A TYPE B DOUBLE-WALL COMMON VENT
152 TABLE B-1 – MASONRY CHIMNEY LINER DIMENSIONS WITH CIRCULAR EQUIVALENTSa
153 FIGURE B-19
155 APPENDIX C (IFGS)
EXIT TERMINALS OF MECHANICAL DRAFT AND
DIRECT-VENT VENTING SYSTEMS
157 APPENDIX D (IFGS)
RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN
EXISTING APPLIANCE INSTALLATION
159 INDEX
163 2007 FLORIDA BUILDING CODE CHAPTER 1 BUILDING
165 CHAPTER 1 ADMINISTRATION
SECTION 101 GENERAL
SECTION 102 APPLICABILITY
167 SECTION 103 DEPARTMENT OF BUILDING SAFETY RESERVED
SECTION 104 DUTIES AND POWERS OF THE BUILDING OFFICIAL
SECTION 105 PERMITS
171 SECTION 106 CONSTRUCTION DOCUMENTS
174 SECTION 107 TEMPORARY STRUCTURES AND USES
SECTION 108 FEES
175 SECTION 109 INSPECTIONS
177 SECTION 110 CERTIFICATES OF OCCUPANCY AND COMPLETION
178 SECTION 111 SERVICE UTILITIES
SECTION 112 BOARD OF APPEALS RESERVED
SECTION 113 VIOLATIONS RESERVED
SECTION 114 STOP WORK ORDER
SECTION 115 UNSAFE STRUCTURES AND EQUIPMENT RESERVED
FL FuelGas 07 2007
$48.34