Shopping Cart

No products in the cart.

ICC IFGC Commentary 2015

$80.71

International Fuel Gas Code and Commentary

Published By Publication Date Number of Pages
ICC 2015 427
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

A practical tool that helps you to master the code you deal with every day!This comprehensive publication provides a convenient reference for regulations in the 2015 International Fuel Gas Code® (IFGC®). Presented in an easy-to-reference format the commentary includes the full text of the code, including tables and figures, followed by corresponding commentary at the end of each section in one document. Every chapter begins with “General Comments” and “Purpose” sections followed by code and commentary to subsequent sections, tables and figures. This in-depth publication focuses on providing the full meaning and implications of the 2015 IFGC®. The commentaries are designed to suggest the most effective method of application, and the consequences of not adhering to the code. This is an excellent reference for code officials, engineers, architects, inspectors, plans examiners, contractors and anyone who needs a better understanding of the 2015 IFGC®.

PDF Catalog

PDF Pages PDF Title
1 2015 INTERNATONAL FUEL GAS CODE® AND COMMENTARY
2 2015 IFGC® CODE AND COMMENTARY TITLE PAGE
3 COPYRIGHT
4 PREFACE
6 TABLE OF CONTENTS
8 CHAPTER 1: SCOPE AND ADMINISTRATION
GENERAL COMMENTS
PURPOSE
PART 1—SCOPE AND APPLICATION
SECTION 101 (IFGC) GENERAL
10 SECTION 102 (IFGC) APPLICABILITY
12 PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION 103 (IFGC) DEPARTMENT OF INSPECTION
SECTION 104 (IFGC) DUTIES AND POWERS OF THE CODE OFFICIAL
14 SECTION 105 (IFGC) APPROVAL
16 SECTION 106 (IFGC) PERMITS
19 SECTION 107 (IFGC) INSPECTIONS AND TESTING
23 SECTION 108 (IFGC) VIOLATIONS
24 SECTION 109 (IFGC) MEANS OF APPEAL
26 SECTION 110 (IFGC) TEMPORARY EQUIPMENT, SYSTEMS AND USES
28 CHAPTER 2: DEFINITIONS
GENERAL COMMENTS
PURPOSE
SECTION 201 (IFGC) GENERAL
SECTION 202 (IFGC) GENERAL DEFINITIONS
30 FIGURE 202(1) ANODELESS RISERS
31 FIGURE 202(2) BAROMETRIC DRAFT REGULATOR
32 FIGURE 202(3) LABEL FOR LOW-PRESSURE BOILER
34 FIGURE 202(4) FACTORY-BUILT CHIMNEYS
FIGURE 202(5) AIR-COOLED FACTORY-BUILT CHIMNEY SECTION
37 FIGURE 202(6) DIRECT-VENT APPLIANCE
FIGURE 202(7) DIRECT-VENT APPLIANCE
38 FIGURE 202(8) DRAFT-HOOD-EQUIPPED APPLIANCE
41 FIGURE 202(9) CHIMNEY FLUE LINER SYSTEM FOR GAS APPLIANCE
42 FIGURE 202(10) GAS CONVENIENCE OUTLET
FIGURE 202(11) GAS CONVENIENCE OUTLET
45 FIGURE 202(12) TYPICAL APPLIANCE LABEL
46 FIGURE 202(13) TYPICAL RESIDENTIAL GAS METER SETTING
47 FIGURE 202(14) VENT OFFSET
FIGURE 202(15) OXYGEN DEPLETION SAFETY SHUTOFF
48 FIGURE 202(16) QUICK-DISCONNECT DEVICE
50 FIGURE 202(17) SERVICE REGULATOR
51 FIGURE 202(18) UNVENTED ROOM HEATER
52 FIGURE 202(19) TRANSITION FITTINGS
53 FIGURE 202(20) TYPE B VENT
55 BIBLIOGRAPHY
56 CHAPTER 3: GENERAL REGULATIONS
GENERAL COMMENTS
PURPOSE
SECTION 301 (IFGC) GENERAL
59 FIGURE 301.5(1) TYPCIAL LABEL FOR A CATEGORY I GAS-FIRED FURNACE
60 FIGURE 301.5(2) ROOFTOP HVAC UNIT LABEL
61 SECTION 302 (IFGC) STRUCTURAL SAFETY
63 FIGURE 302.3.2(1) CUTTING, NOTCHING AND BORING IN JOIST
FIGURE 302.3.2(2) BORING JOISTS
64 FIGURE 302.3.3 BORING AND NOTCHING OF STUDS
65 SECTION 303 (IFGC) APPLIANCE LOCATION
66 FIGURE 303.3(1) UNVENTED WALL-MOUNTED ROOM HEATER
67 FIGURE 303.3(2) APPLIANCE ENCLOSURE
FIGURE 303.4 APPLIANCE PROTECTED FROM VEHICLE IMPACT
68 SECTION 304 (IFGS) COMBUSTION, VENTILATION AND DILUTION AIR
69 FIGURE 304.1(1) THE CHEMISTRY OF IDEAL COMBUSTION
FIGURE 304.1(2) THE CHEMISTRY OF INCOMPLETE COMBUSTION
70 FIGURE 304.1(3) COMBUSTION AIR SUPPLY METHODS
71 FIGURE 304.1(4) DIRECT-VENT APPLIANCE
FIGURE 304.1(5) DIRECT COMBUSTION AIR CONNECTION TO THE OUTDOORS
FIGURE 304.1(6) BOILER WITH POWER BURNER
73 FIGURE 304.4 DEPLETION OF COMBUSTION AIR
EQUATION 3-1
74 EQUATION 3-2
FIGURE 304.5.3 ALL AIR FROM INSIDE THE BUILDING (see Section 304.5.3)
75 FIGURE 304.5.2 CALCULATED VOLUMES
77 FIGURE 304.5.3.2 COMBINING SPACES IN DIFFERENT STORIES
78 FIGURE 304.6.1(1) ALL AIR FROM OUTDOORS—INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC (see Section 304.6.1)
FIGURE 304.6.1(2) ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC (see Section 304.6.1)
FIGURE 304.6.1(3) ALL AIR FROM OUTDOORS (see Section 304.6.1)
79 FIGURE 304.6.2 SINGLE COMBUSTION AIR OPENING, ALL AIR FROM THE OUTDOORS (see Section 304.6.2)
81 FIGURE 304.7.3 ROOM CONFIGURATION USED IN EXAMPLE 2
82 FIGURE 304.8(1) MECHANICAL COMBUSTION AIR/MAKEUP AIR SUPPLY SYSTEM
FIGURE 304.8(2) MECHANICAL COMBUSTION AIR SUPPLY SYSTEM
83 FIGURE 304.8(3) MECHANICAL COMBUSTION AIR/MAKEUP AIR SUPPLY SYSTEM
FIGURE 304.9 MECHANICALLY SUPPLIED COMBUSTION AIR
84 FIGURE 304.9.2 SIMPLIFIED EXAMPLE SCHEMATIC OF INTERLOCK BETWEEN APPLIANCE AND POWER COMBUSTION AIR UNIT
86 FIGURE 304.10 SIMPLIFIED EXAMPLE SCHEMATIC OF COMBUSTION AIR DAMPER/APPLIANCE INTERLOCK
87 FIGURE 304.11 COMMON DUCT PROHIBITED
SECTION 305 (IFGC) INSTALLATION
89 FIGURE 305.3(1) GAS-FIRED WATER HEATER INSTALLATION IN A GARAGE
90 FIGURE 305.3(2) SOURCES OF IGNITION ELEVATED IN PRIVATE GARAGE
FIGURE 305.3(3) GARAGE SPACE VS. LIVING SPACE
FIGURE 305.3(4) EXAMPLE OF FLAMMABLE VAPOR IGNITION RESISTANT WATER HEATER TECHNOLOGY
91 FIGURE 305.3(5) EXAMPLE OF FLAMMABLE VAPOR IGNITION RESISTANT WATER HEATER TECHNOLOGY
FIGURE 305.3(6) EXAMPLE OF FLAMMABLE VAPOR IGNITION RESISTANT WATER HEATER TECHNOLOGY
FIGURE 305.3.1 ELEVATION OF APPLIANCES NOT REQUIRED
93 FIGURE 305.5(1) SUSPENDED UNIT HEATER
FIGURE 305.5(2) PROTECTED BY WALLS
94 FIGURE 305.5(3) PROTECTED BY GUARDS
FIGURE 305.5(4) PROTECTED BY A PLATFORM
95 FIGURE 305.5(5) PROTECTED BY A CURB STOP
96 SECTION 306 (IFGC) ACCESS AND SERVICE SPACE
97 FIGURE 306.3 ATTIC FURNACE INSTALLATION
98 FIGURE 306.4 CRAWL SPACE FURNACE INSTALLATION
99 FIGURE 306.5 APPLIANCE ACCESS
100 FIGURE 306.5.1 ROOFTOP HVAC UNIT WITH WORK PLATFORM
101 FIGURE 306.6(1) GUARDS
102 FIGURE 306.6(2) ROOF PLAN VIEW
SECTION 307 (IFGC) CONDENSATE DISPOSAL
103 FIGURE 307.4 AUXILIARY DRAIN PAN REQUIRED (WITH OR WITHOUT COOLING COIL)
104 FIGURE 307.3 CONDENSATE PUMP
SECTION 308 (IFGS) CLEARANCE REDUCTION
105 FIGURE 308.1 CLEARANCE TO COMBUSTIBLES—EXAMPLES OF HOW TO MEASURE
106 FIGURE 308.2(1) EXTENT OF PROTECTION NECESSARY TO REDUCE CLEARANCES FROM APPLIANCE OR VENT CONNECTIONS
FIGURE 308.2(2) WALL PROTECTOR CLEARANCE REDUCTION SYSTEM
FIGURE 308.2(3) MASONRY CLEARANCE REDUCTION SYSTEM
107 TABLE 308.2 a through k REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTION
108 FIGURE 308.2 REDUCED CLEARANCE TO COMBUSTIBLES
110 SECTION 309 (IFGC) ELECTRICAL
SECTION 310 (IFGS) ELECTRICAL BONDING
111 FIGURE 310.1 GAS PIPE BONDING BY APPLIANCE BRANCH CIRCUIT
112 FIGURE 310.1.1.1 POINT OF CONNECTION
113 FIGURE 310.1.1(1) CSST BONDING
FIGURE 310.1.1(2) ALTERNATIVE LOCATION FOR BONDING CLAMP
114 BIBLIOGRAPHY
115 FIGURE 310.1.1.3 BONDING JUMPER LENGTH
116 CHAPTER 4: GAS PIPING INSTALLATIONS
GENERAL COMMENTS
FIGURE 400 GAS FLAMMABILITY LIMITS
PURPOSE
117 SECTION 401 (IFGC) GENERAL
FIGURE 401.1(1) SCOPE OF CODES
118 FIGURE 401.1(2) TYPICAL POINT OF DELIVERY FOR NATURAL GAS SERVICE
120 SECTION 402 (IFGS) PIPE SIZING
121 EQUATION 4-1
EQUATION 4-2
122 TABLE 402.4 Cr AND Y VALUES FOR NATURAL GAS AND UNDILUTED PROPANE AT STANDARD CONDITIONS
FIGURE 402.4 GAS PIPING LAYOUT
123 FIGURE 402.4.1 STEEL PIPE BRANCH SYSTEM FOR ROOFTOP UNITS
124 FIGURE 402.4.2(1) BRANCH PIPING SYSTEM WITH SCHEDULE 40 STEEL PIPE TRUNKLINE AND CSST BRANCHES
FIGURE 402.4.2(2) SINGLE PRESSURE CSST MANIFOLD SYSTEM
126 SUMMARY TABLE FOR BRANCH LENGTH METHOD EXAMPLE 2
127 SUMMARY TABLE FOR HYBRID PRESSURE EXAMPLE 2
128 FIGURE 402.4.3(1) HYBRID PRESSURE BRANCH SYSTEM
FIGURE 402.4.3(2) HYBRID PRESSURE PARALLEL DISTRIBUTION SYSTEM
130 TABLE 402.4(1) SCHEDULE 40 METALLIC PIPE
131 TABLE 402.4(2) SCHEDULE 40 METALLIC PIPE
132 TABLE 402.4(3) SCHEDULE 40 METALLIC PIPE
133 TABLE 402.4(4) SCHEDULE 40 METALLIC PIPE
134 TABLE 402.4(5) SCHEDULE 40 METALLIC PIPE
135 TABLE 402.4(6) SCHEDULE 40 METALLIC PIPE
136 TABLE 402.4(7) SCHEDULE 40 METALLIC PIPE
137 TABLE 402.4(8) SEMIRIGID COPPER TUBING
138 TABLE 402.4(9) SEMIRIGID COPPER TUBING
139 TABLE 402.4(10) SEMIRIGID COPPER TUBING
140 TABLE 402.4(11) SEMIRIGID COPPER TUBING
141 TABLE 402.4(12) SEMIRIGID COPPER TUBING
142 TABLE 402.4(13) SEMIRIGID COPPER TUBING
143 TABLE 402.4(14) SEMIRIGID COPPER TUBING
144 TABLE 402.4(15) CORRUGATED STAINLESS STEEL TUBING (CSST)
145 TABLE 402.4(16) CORRUGATED STAINLESS STEEL TUBING (CSST)
146 TABLE 402.4(17) CORRUGATED STAINLESS STEEL TUBING (CSST)
147 TABLE 402.4(18) CORRUGATED STAINLESS STEEL TUBING (CSST)
148 TABLE 402.4(19) CORRUGATED STAINLESS STEEL TUBING (CSST)
149 TABLE 402.4(20) POLYETHYLENE PLASTIC PIPE
150 TABLE 402.4(21) POLYETHYLENE PLASTIC PIPE
151 TABLE 402.4(22) POLYETHYLENE PLASTIC PIPE
152 TABLE 402.4(23) POLYETHYLENE PLASTIC TUBING
TABLE 402.4(24) POLYETHYLENE PLASTIC TUBING
153 TABLE 402.4(25) SCHEDULE 40 METALLIC PIPE
154 TABLE 402.4(26) SCHEDULE 40 METALLIC PIPE
155 TABLE 402.4(27) SCHEDULE 40 METALLIC PIPE
156 TABLE 402.4(28) SCHEDULE 40 METALLIC PIPE
157 TABLE 402.4(29) SEMIRIGID COPPER TUBING
158 TABLE 402.4(30) SEMIRIGID COPPER TUBING
159 TABLE 402.4(31) SEMIRIGID COPPER TUBING
160 TABLE 402.4(32) CORRUGATED STAINLESS STEEL TUBING (CSST)
161 TABLE 402.4(33) CORRUGATED STAINLESS STEEL TUBING (CSST)
162 TABLE 402.4(34) CORRUGATED STAINLESS STEEL TUBING (CSST)
163 TABLE 402.4(35) POLYETHYLENE PLASTIC PIPE
164 TABLE 402.4(36) POLYETHYLENE PLASTIC PIPE
165 TABLE 402.4(37) POLYETHYLENE PLASTIC TUBING
166 SECTION 403 (IFGS) PIPING MATERIALS
FIGURE 403.5 PLASTIC-SHEATHED COPPER TUBING
167 FIGURE 403.5.4(1) CSST AND SYSTEM COMPONENTS
FIGURE 403.5.4 (2) CSST FITTING
168 FIGURE 403.5.4(3) CSST FITTING
FIGURE 403.5.4(4) CSST FITTING
FIGURE 403.5.4(5) MULTIPORT MANIFOLD INSTALLATION USING CSST
FIGURE 403.5.4(6) TOP PLATE TUBING PROTECTION SHIELD
169 FIGURE 403.5.4(7) LOW-PRESSURE GAS PIPING SYSTEM USING CSST
FIGURE 403.5.4(8) MEDIUM-PRESSURE GAS PIPING SYSTEM USING CSST
170 FIGURE 403.5.4(9) CSST MANUFACTURED FOR UNDERGROUND INSTALLATION
171 FIGURE 403.5.4 (10) EXCERPT FROM CSST MANUFACTURER’S INSTALLATION INSTRUCTIONS
FIGURE 403.5.4(11) EXCERPT FROM CSST MANUFACTURER’S INSTALLATION INSTRUCTIONS
FIGURE 403.5.4(12) MANIFOLD FOR 2 PSI PARALLEL DISTRIBUTION SYSTEM
172 FIGURE 403.5.4(13) “STUB-OUT” TERMINATION TRANSITION FITTING
FIGURE 403.5.4(14) “VALVE BOX” TERMINATION TRANSITION FITTING
FIGURE 403.5.4(15) TERMINATION TRANSITION FITTING
173 FIGURE 403.6 APPROVED POLYETHYLENE GAS PIPING WITH MARKINGS IN ACCORDANCE WITH THE CODE AND ASTM D2513
FIGURE 403.6.1(1) SERVICE HEAD ADAPTERS
174 FIGURE 403.6.1(2) SERVICE HEAD ADAPTERS
FIGURE 403.6.1(3) FLEXIBLE ANODELESS RISER
175 FIGURE 403.9 TAPERED THREAD COUPLING IN CONNECTION TO FURNACE
TABLE 403.9.2 SPECIFICATIONS FOR THREADING METALLIC PIPE
176 FIGURE 403.10.2 PRESS-CONNECT COPPER FITTING
178 FIGURE 403.10.4(1) METER SETTING
FIGURE 403.10.4(2) ELBOW WITH DRILLED AND TAPPED HOLE
180 FIGURE 403.11(1) MECHANICAL JOINTS
FIGURE 403.11(2) MECHANICAL JOINT
SECTION 404 (IFGC) PIPING SYSTEM INSTALLATION
181 FIGURE 403.11(3) PLASTIC PIPE TRANSITION FITTING
FIGURE 403.11(4) PLASTIC PIPE TRANSITION FITTING
182 FIGURE 403.12 FLANGED JOINTS
183 FIGURE 404.3 PROHIBITED TOWNHOUSE INSTALLATION
184 FIGURE 404.6 ABOVE GRADE ENTRANCE/EXIT
185 FIGURE 404.7 PIPE PROTECTION
FIGURE 404.8 PIPING IN SOLID FLOORS
186 FIGURE 404.8.2 PIPE UNDER SLAB BETWEEN INTERIOR POINTS
187 FIGURE 404.10 LP-GAS PIPING ISOLATION
188 FIGURE 404.12 MINIMUM BURIAL DEPTH
190 FIGURE 404.17.1 PIPING UNDER SLABS
191 SECTION 405 (IFGS) PIPING BENDS AND CHANGES IN DIRECTION
192 SECTION 406 (IFGS) INSPECTION, TESTING AND PURGING
193 FIGURE 406.1.4 PIPING ISOLATION ARRANGEMENT FOR TESTING
194 FIGURE 406.3.3 MANUFACTURER’S WARNING REGARDING PRESSURE TESTING OF GAS PIPING
195 FIGURE 406.4(1) TYPICAL TEST SET-UP FOR AIR PRESSURE TESTING
FIGURE 406.4(2) ELECTRONIC PRESSURE GAUGE
196 FIGURE 406.4(3) LEAK DETECTOR INSTRUMENT
FIGURE 406.4(4) ELECTRONIC LEAK DETECTOR INSTRUMENT
198 TABLE 406.7.1.1 SIZE AND LENGTH OF PIPING
200 SECTION 407 (IFGC) PIPING SUPPORT
201 SECTION 408 (IFGC) DRIPS AND SLOPED PIPING
FIGURE 408.4 METHOD OF INSTALLING A TEE FITTING SEDIMENT TRAP
202 FIGURE 408.4(1) EFFECTIVE SEDIMENT TRAP
FIGURE 408.4(2) LESS EFFECTIVE OR INEFFECTIVE SEDIMENT TRAP CONFIGURATION
SECTION 409 (IFGC) SHUTOFF VALVES
203 FIGURE 409.1.1(1) TYPICAL BALL-TYPE GAS SHUTOFF VALVE
FIGURE 409.1.1(2) BALL-TYPE GAS SHUTOFF VALVE DESIGNED TO MATE WITH A CONNECTOR
TABLE 409.1.1 MANUAL GAS VALVE STANDARDS
204 FIGURE 409.5.1 SHUTOFF VALVE IN CONTROL COMPARTMENT OF GAS FIREPLACE
206 SECTION 410 (IFGC) FLOW CONTROLS
FIGURE 410.1(1) GAS PRESSURE REGULATORS
207 FIGURE 410.1(2) SERVICE REGULATOR
FIGURE 410.1(3) GAS PRESSURE REGULATOR
208 FIGURE 410.1(4) SYSTEM PRESSURES
209 FIGURE 410.2(1) SYSTEM PRESSURES
FIGURE 410.2(2) PRESSURE REGULATOR/OVERPRESSURE PROTECTION DEVICE ASSEMBLIES
210 FIGURE 410.2(3) AT LEAST ONE UNION, INSTALLED UPSTREAM OR DOWNSTREAM, IS REQUIRED FOR AN MP REGULATOR CONNECTED TO RIGID PIPING
FIGURE 410.3(1) REGULATOR WITH VENT PROTECTION
211 FIGURE 410.3(2) PRESSURE REGULATOR WITH VENT-LIMITING DEVICE
FIGURE 410.4 EXAMPLE OF EXCESS FLOW VALVE
SECTION 411 (IFGC) APPLIANCE AND MANUFACTURED HOME CONNECTIONS
213 FIGURE 411.1(1) PIPING SYSTEM SIZING AND APPLIANCE CONNECTION AND CONNECTOR SIZING
FIGURE 411.1(2) QUICK-DISCONNECT DEVICE FOR USE WITH COMMERCIAL APPLIANCE CONNECTORS
FIGURE 411.1(3) QUICK-DISCONNECT DEVICE FOR USE WITH COMMERCIAL APPLIANCE CONNECTORS
214 FIGURE 411.1(4) CSST DIRECTLY CONNECTED TO NONMOVEABLE APPLIANCE
FIGURE 411.1(5) CSST TERMINATED AT APPLIANCE LOCATION
215 FIGURE 411.1(6) SEMIRIGID (FLEXIBLE) APPLIANCE CONNECTOR
FIGURE 411.1(7) OUTDOOR MOBILE HOME CONNECTOR
FIGURE 411.1(8) NATURAL GAS HOSE AND CONNECTOR FOR PORTABLE OUTDOOR GAS APPLIANCES
216 FIGURE 411.1.1(1) COMMERCIAL COOKING APPLIANCE CONNECTOR WITH TRAVEL RESTRAINT
FIGURE 411.1.1(2) COMMERCIAL COOKING APPLIANCE CONNECTOR WITH TRAVEL RESTRAINT
FIGURE 411.1.1(3) COMMERCIAL COOKING APPLIANCE FUEL CONNECTORS
FIGURE 411.1.1(4) COMMERCIAL COOKING APPLIANCE FUEL CONNECTORS
217 FIGURE 411.1.3.1(1) APPLIANCE FUEL CONNECTOR
FIGURE 411.1.3.1(2) APPLIANCE FUEL CONNECTOR
218 FIGURE 411.1.3.3 CONNECTOR PIPING DOWNSTREAM OF SHUTOFF VALVE
219 FIGURE 411.3(1) EXAMPLE OF ONE MANUFACTURER’S INSTALLATION INSTRUCTIONS
220 FIGURE411.3(2) END VIEW OF FIGURE 411.3(1)
SECTION 412 (IFGC) LIQUEFIED PETROLEUM GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES
222 SECTION 413 (IFGC) COMPRESSED NATURAL GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES
223 FIGURE 413.1 CNG FUEL-DISPENSING STATION
225 [F] TABLE 413.9.2.3 SEPARATION DISTANCE FOR ATMOSPHERIC VENTING OF CNG
SECTION 414 (IFGC) SUPPLEMENTAL AND STANDBY GAS SUPPLY
226 SECTION 415 (IFGS) PIPING SUPPORT INTERVALS
TABLE 415.1 SUPPORT OF PIPING
SECTION 416 (IFGS) OVERPRESSURE PROTECTION DEVICES
228 BIBLIOGRAPHY
230 CHAPTER 5: CHIMNEYS AND VENTS
GENERAL COMMENTS
PURPOSE
SECTION 501 (IFGC) GENERAL
231 FIGURE 501.6 VENT DESIGNED FOR CATEGORY III AND IV (POSITIVE PRESSURE) APPLICATIONS
234 FIGURE 501.13(1) MASONRY CHIMNEY RELINING SYSTEM
FIGURE 501.13(2) MASONRY CHIMNEY RELINING SYSTEM
FIGURE 501.13(3) MASONRY CHIMNEY RELINING BY INSTALLATION OF TYPE B VENT SYSTEM
235 FIGURE 501.13(4) MASONRY CHIMNEY RELINING SYSTEM
FIGURE 501.14 SPECIAL VENT SYSTEM FOR CATEGORY II, III AND IV APPLIANCES
236 FIGURE 501.15.1 APPLIANCE REPLACEMENTS AFFECTING EXISTING APPLIANCES
237 SECTION 502 (IFGC) VENTS
FIGURE 502.1(1) CATEGORY I FAN-ASSISTED FURNACE
238 FIGURE 502.1(2) CATEGORY IV APPLIANCE (FURNACE)
FIGURE 502.1(3) TYPE B GAS VENT SERVING TWO CATEGORY I APPLIANCES
239 FIGURE 502.1(4) TYPE B VENT SECTIONS WITH AIR SPACE BETWEEN PIPE WALLS
240 FIGURE 502.7 PLAN VIEW OF STUD WALL
FIGURE 502.7.1(1) DOOR SWING
241 FIGURE 502.7.1(2) DOOR SWING
SECTION 503 (IFGS) VENTING OF APPLIANCES
242 FIGURE 503.2.3(1) DIRECT-VENT APPLIANCE
FIGURE 503.2.3(2) DIRECT-VENT (SEPARATED COMBUSTION) UNIT HEATERS
FIGURE 503.2.3(3) EXAMPLE OF MANUFACTURER’S DETAIL FOR DIRECT-VENT APPLIANCE CONCENTRIC VENT-AIR INTAKE TERMINAL
FIGURE 503.2.3(4) DIRECT-VENT APPLIANCES
243 FIGURE 503.2.3(5) GRAVITY DIRECT-VENT WATER HEATER
FIGURE 503.2.3(6) DIRECT-VENT SYSTEM COMPONENTS
FIGURE 503.2.4(1) HOT WATER BOILER WITH INTEGRAL VENT FOR OUTDOOR INSTALLATION
244 FIGURE 503.2.4(2) OUTDOOR DUCT FURNACE WITH INTEGRAL POWER VENTING
FIGURE 503.2.4(3) ROOFTOP HVAC UNIT WITH INTEGRAL POWER VENT
246 FIGURE 503.3.3(1) VERTICAL DRAFT INDUCER
FIGURE 503.3.3(2) HORIZONTAL POWER EXHAUSTER
FIGURE 503.3.3(3) HORIZONTAL POWER EXHAUSTERS
FIGURE 503.3.3(4) VERTICAL POWER EXHAUSTERS
FIGURE 503.3.3(5) VERTICAL POWER EXHAUSTERS
247 FIGURE 503.3.3(6) POWER EXHAUSTER OUTDOOR TERMINAL-TYPE UNIT
FIGURE 503.3.3(7) EXHAUSTER AND CONTROL PACKAGE
FIGURE 503.3.3(8) TYPICAL POWER EXHAUSTER
FIGURE 503.3.3(9) TYPICAL EXHAUSTER APPLICATIONS
FIGURE 503.3.3(10) DRAFT INDUCER
248 FIGURE 503.3.3(11) DRAFT INDUCER
FIGURE 503.3.3 (12) POWER-VENTED WATER HEATER
FIGURE 503.3.3(13) DRAFT CONDITIONS WITH EQUIPMENT BURNER-INLET BLOWER
249 FIGURE 503.3.3(14) SIMPLIFIED SAMPLE INTERLOCK CIRCUIT DIAGRAM FOR APPLIANCE SERVED BY POWER EXHAUSTER
250 FIGURE 503.3.6 VENTS THROUGH AIR PLENUMS
FIGURE 503.4 DETERMINING VENT HEIGHT
251 FIGURE 503.4.1 DIRECT-VENT APPLIANCE
TABLE 503.4 TYPE OF VENTING SYSTEM TO BE USED
254 FIGURE 503.5.4(1) LOW-HEAT CHIMNEY TERMINATIONS
FIGURE 503.5.4(2) DECORATIVE SHROUDS
255 FIGURE 503.5.6.1(1) CHIMNEY LINING SYSTEM FOR GAS APPLIANCES
FIGURE 503.5.6.1(2) DIRECT-VENT APPLIANCE FOR INSTALLATION IN SOLID FUEL FIREPLACE
258 FIGURE 503.6.4 TERMINATION LOCATIONS FOR GAS VENTS WITH LISTED CAPS 12 INCHES OR LESS IN SIZE AT LEAST 8 FEET FROM A VERTICAL WALL
259 FIGURE 503.6.4 TOP LOCATION RULES
FIGURE 503.6.4.1 DECORATIVE SHROUDS
260 FIGURE 503.6.7 B-VENT TERMINATIONS WITH RESPECT TO FORCED AIR INTAKES
262 FIGURE 503.6.10.1(1) APPLIANCE AND VENT SEPARATED FROM LIVING SPACE
263 FIGURE 503.6.10.1(2) APPLIANCE CLOSETS ACCESSED FROM OUTDOOR BALCONY
FIGURE 503.6.13 FASTENER PENETRATIONS
267 FIGURE 503.8(1) MECHANICAL DRAFT VENTING SYSTEM EXHAUSTER TERMINATIONS
268 FIGURE 503.8(2) EXAMPLE OF MANUFACTURER’S DETAIL FOR DIRECT-VENT APPLIANCE
FIGURE 503.8(3) EXAMPLE OF MANUFACTURER’S DETAIL FOR DIRECT-VENT APPLIANCE VENT AND COMBUSTION AIR TERMINALS
269 FIGURE 503.8(4) DIRECT-VENT HOT WATER BOILER
FIGURE 503.8(5) VENT TERMINATION
270 FIGURE 503.10.2.2 LISTED BENDABLE DOUBLE-WALL CONNECTOR
271 TABLE 503.10.2.4 MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES
TABLE 503.10.2.5 MINIMUM THICKNESS FOR STEEL VENT CONNECTORS FOR MEDIUM-HEAT APPLIANCES
273 FIGURE 503.10.3.4(1) MANIFOLD SIZING
FIGURE 503.10.3.4(2) COMMON VENT OFFSET AND MANIFOLD
274 FIGURE 503.10.4.1 OPPOSING OPENINGS IN CHIMNEY
TABLE 503.10.5a CLEARANCES FOR CONNECTORS
275 FIGURE 503.10.8 VENT HEIGHT
277 FIGURE 503.10.13 TYPE B VENT CONNECTOR PENETRATIONS
FIGURE 503.12.1 DRAFT-HOOD-EQUIPPED APPLIANCE
280 FIGURE 503.14 AUTOMATIC VENT DAMPERS
281 SECTION 504 (IFGS) SIZING OF CATEGORY I APPLIANCE VENTING SYSTEMS
282 FIGURE 504.1(1) COMBUSTION PROCESS FOR NATURAL GAS
FIGURE 504.1(2) FLUE GAS COMPOSITION
FIGURE 504.1(3) DRAFT-HOOD APPLIANCE COMPARED TO FAN-ASSISTED APPLIANCE
283 FIGURE 504.1(4) ILLUSTRATION OF THE BASIC PRINCIPLE OF FAN-ASSISTED COMBUSTION
FIGURE 504.1(5) FAN-ASSISTED HOT WATER BOILER
284 FIGURE 504.2(1) EXAMPLE OF INDIVIDUAL VENT DIMENSIONS
285 FIGURE 504.2(2) INDIVIDUAL VENT—LATERAL AND HEIGHT
FIGURE 504.2.1 CATEGORY I NATURAL DRAFT HOT WATER BOILER WITH AUTOMATIC VENT DAMPER
289 FIGURE 504.2.9 HEIGHT ABOVE ROOF
290 FIGURE 504.2.9(1) MASONRY CHIMNEY COMPARED TO TYPE B VENT
FIGURE 504.2.9(2) EXTERIOR CHIMNEY SIZING-EXAMPLE
295 FIGURE 504.3(1) COMBINED VENT DIMENSIONS
296 FIGURE 504.3(2) FAN AND NAT VENT SIZING EXAMPLE
297 TABLE 504.3.2 MAXIMUM VENT CONNECTOR LENGTH
299 FIGURE 504.3.5 COMMON VENT OFFSET IN ATTIC FOR THE PURPOSE OF AVOIDING A STREET-SIDE ROOF PENETRATION
300 FIGURE 504.3.6(1) OFFSET IN COMMON VENT AND CONNECTORS
FIGURE 504.3.6(2) TYPE B VENT ADJUSTABLE 45-DEGREE ELBOW FITTING
FIGURE 504.3.6(3) TYPE B VENT ADJUSTABLE 90-DEGREE ELBOW FITTING
301 FIGURE 504.3.9(1) TYPE B VENT REDUCING TEE
FIGURE 504.3.9(2) TYPE B VENT REDUCING WYE
302 FIGURE 504.3.9.1 SINGLE-WALL TEES AND WYES PROHIBITED IN TYPE B COMMON VENT SYSTEMS
303 FIGURE 504.3.11 CONNECTOR RISE
304 FIGURE 504.3.20 EXTERIOR CHIMNEY SIZING—EXAMPLE
305 SECTION 505 (IFGC) DIRECT-VENT, INTEGRAL VENT, MECHANICAL VENT AND VENTILATION/EXHAUST HOOD VENTING
306 FIGURE 505.1.1(1) EXHAUST HOOD INTERLOCK WITH COOKING APPLIANCES (SOLENOID)
307 FIGURE 505.1.1(2) PROHIBITED SOLENOID VALVE BYPASS
SECTION 506 (IFGC) FACTORY-BUILT CHIMNEYS
FIGURE 506.1(1) FACTORY-BUILT CHIMNEY
308 FIGURE 506.1(2) AIR-COOLED FACTORY-BUILT CHIMNEY SYSTEM
BIBLIOGRAPHY
309 TABLE 504.2(1) TYPE B DOUBLE-WALL GAS VENT
310 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
311 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
312 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
313 TABLE 504.2(2) TYPE B DOUBLE-WALL GAS VENT
314 TABLE 504.2(2)—continued TYPE B DOUBLE-WALL GAS VENT
315 TABLE 504.2(3) MASONRY CHIMNEY
316 TABLE 504.2(3)—continued MASONRY CHIMNEY
317 TABLE 504.2(4) MASONRY CHIMNEY
318 TABLE 504.2(4)—continued MASONRY CHIMNEY
319 TABLE 504.2(5) SINGLE-WALL METAL PIPE OR TYPE B ASBESTOS CEMENT VENT
320 TABLE 504.2(6) EXTERIOR MASONRY CHIMNEY
321 TABLE 504.3(1) TYPE B DOUBLE-WALL VENT
322 TABLE 504.3(1)—continued TYPE B DOUBLE-WALL VENT
323 TABLE 504.3(2) TYPE B DOUBLE-WALL VENT
324 TABLE 504.3(3) MASONRY CHIMNEY
325 TABLE 504.3(4) MASONRY CHIMNEY
326 TABLE 504.3(5) SINGLE-WALL METAL PIPE OR TYPE ASBESTOS CEMENT VENT
327 TABLE 504.3(6a) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(6b) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(6b) EXTERIOR MASONRY CHIMNEY—continued
328 TABLE 504.3(7a) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(7b) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(7b) EXTERIOR MASONRY CHIMNEY—continued
330 CHAPTER 6: SPECIFIC APPLIANCES
GENERAL COMMENTS
PURPOSE
SECTION 601 (IFGC) GENERAL
SECTION 602 (IFGC) DECORATIVE APPLIANCES FOR INSTALLATION IN FIREPLACES
FIGURE 602.1 VENTED GAS LOG SET
332 FIGURE 602.2(1) COMBINATION GAS CONTROL
FIGURE 602.2(2) COMBINATION GAS CONTROL FOR APPLIANCES
333 SECTION 603 (IFGC) LOG LIGHTERS
SECTION 604 (IFGC) VENTED GAS FIREPLACES (DECORATIVE APPLIANCES)
FIGURE 604.1(1) VENTED DECORATIVE APPLIANCE
FIGURE 604.1(2) DIRECT-VENT DECORATIVE APPLIANCE
334 FIGURE 604.1(3) DIRECT-VENT GAS FIREPLACE
SECTION 605 (IFGC) VENTED GAS FIREPLACE HEATERS
FIGURE 605.1 VENTED GAS FIREPLACE HEATER
SECTION 606 (IFGC) INCINERATORS AND CREMATORIES
335 SECTION 607 (IFGC) COMMERCIAL-INDUSTRIAL INCINERATORS
SECTION 608 (IFGC) VENTED WALL FURNACES
336 SECTION 609 (IFGC) FLOOR FURNACES
FIGURE 609.1 FLOOR FURNACE
337 SECTION 610 (IFGC) DUCT FURNACES
FIGURE 610.1(1) INTEGRAL POWER-VENTED OUTDOOR DUCT FURNACE
FIGURE 610.1(2) INTEGRAL GRAVITY-VENTED OUTDOOR DUCT FURNACE
FIGURE 610.1(3) OUTDOOR DUCT FURNACES WITH AIR HANDLER
338 FIGURE 610.1(4) DUCT FURNACE
SECTION 611 (IFGC) NONRECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS
339 FIGURE 611.1 DIRECT-FIRED MAKE-UP AIR HEATER
340 SECTION 612 (IFGC) RECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS
FIGURE 612.1(1) BASIC PRINCIPLE OF DIRECT-FIRED SPACE HEATING APPLIANCE
341 FIGURE 612.1(2) BASIC PRINCIPLE OF INDIRECT-FIRED SPACE HEATING APPLIANCE
342 SECTION 613 (IFGC) CLOTHES DRYERS
FIGURE 613.1 TYPE 1 CLOTHES DRYER LABEL
SECTION 614 (IFGC) CLOTHES DRYER EXHAUST
344 FIGURE 614.5(1) DEDPV
345 FIGURE 614.5(2) DEDPV
347 FIGURE 614.8.2 DUCT JOINTS
348 [M] TABLE 614.8.4.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH
349 FIGURE 614.8.5 EXAMPLE OF A DRYER EXHAUST LENGTH LABEL
350 FIGURE 614.8.6 MULTIPLE DRYER EXHAUST SYSTEM
351 SECTION 615 (IFGC) SAUNA HEATERS
352 SECTION 616 (IFGC) ENGINE AND GAS TURBINE-POWERED EQUIPMENT
SECTION 617 (IFGC) POOL AND SPA HEATERS
353 SECTION 618 (IFGC) FORCED-AIR WARM-AIR FURNACES
354 SECTION 619 (IFGC) CONVERSION BURNERS
355 SECTION 620 (IFGC) UNIT HEATERS
FIGURE 620.1(1) DIRECT-VENT UNIT HEATER
FIGURE 620.1(2) POWER-VENTED UNIT HEATER
356 FIGURE 620.1(3) UNIT HEATER VENTING (TYPICAL)
FIGURE 620.1(4) DRAFT-HOOD-EQUIPPED UNIT HEATER
SECTION 621 (IFGC) UNVENTED ROOM HEATERS
357 FIGURE 620.1(5) FUNDAMENTAL COMPONENTS OF UNIT HEATER
FIGURE 620.2 UNIT HEATER SUPPORT
358 FIGURE 621.1(1) UNVENTED ROOM HEATER
FIGURE 621.2 UNVENTED ROOM HEATER (DECORATIVE)
FIGURE 621.1(2) FIREBOX FOR UNVENTED ROOM HEATER
359 SECTION 622 (IFGC) VENTED ROOM HEATERS
FIGURE 622.1(1) VENTED GAS FIREPLACE HEATER
FIGURE 622.1(2) VENTED ROOM HEATER
SECTION 623 (IFGC) COOKING APPLIANCES
360 FIGURE 623.1(1) COMMERCIAL OVEN
FIGURE 623.1(2) COMMERCIAL DECK OVEN
361 FIGURE 623.2(1) DOMESTIC RANGE
FIGURE 623.2(2) DOMESTIC RANGE
FIGURE 623.3(1) DOMESTIC (HOUSEHOLD) RANGE
FIGURE 623.3(2) HOUSEHOLD-TYPE COOKING APPLIANCE LABEL
362 FiIGURE 623.7 CLEARANCE ABOVE COOKING TOP
363 SECTION 624 (IFGC) WATER HEATERS
FIGURE 624.2(1) DIRECT-VENT WATER HEATER DESIGNED FOR BOTH POTABLE WATER HEATING AND SPACE HEATING APPLICATIONS
SECTION 625 (IFGC) REFRIGERATORS
364 FIGURE 624.2(2) WATER HEATER LABEL INDICATING SUITABILITY FOR BOTH POTABLE WATER HEATING AND SPACE HEATING
SECTION 626 (IFGC) GAS-FIRED TOILETS
SECTION 627 (IFGC) AIR-CONDITIONING APPLIANCES
366 SECTION 628 (IFGC) ILLUMINATING APPLIANCES
SECTION 629 (IFGC) SMALL CERAMIC KILNS
SECTION 630 (IFGC) INFRARED RADIANT HEATERS
367 FIGURE 630.1(1) CERAMIC BURNER INFRARED RADIANT HEATER
FIGURE 630.1(2) TUBE-TYPE INFRARED RADIANT HEATER
FIGURE 630.1(3) TUBE-TYPE INFRARED RADIANT HEATER
368 FIGURE 630.1(4) SAMPLE LABEL INFRARED RADIANT TUBE HEATER
369 SECTION 631 (IFGC) BOILERS
FIGURE 631.1(1) STEAM HEATING BOILER WITH GAUGE-GLASS, LOW WATER CUTOFF CONTROL, PRESSURE GAUGE, PRESSURE LIMIT CONTROL AND AUTOMATIC VENT DAMPER
FIGURE 631.1(2) STEAM BOILER WITH POWER BURNER, LOW-WATER CUTOFF CONTROLS AND PRESSURE CONTROLS
370 FIGURE 631.2(1) ELECTRONIC PROBE-TYPE LOW-WATER CUTOFF CONTROL WITH GAUGE GLASS AND TRI-COCKS FOR STEAM BOILER APPLICATION
FIGURE 631.2(2) ELECTRONIC PROBE-TYPE LOW-WATER CUTOFF CONTROL FOR HOT WATER BOILER APPLICATION
FIGURE 631.2(3) ELECTRONIC PROBE-TYPE LOW-WATER CUTOFF CONTROL FOR HOT WATER BOILER APPLICATION
SECTION 632 (IFGC) EQUIPMENT INSTALLED IN EXISTING UNLISTED BOILERS
SECTION 633 (IFGC) STATIONARY FUEL-CELL POWER SYSTEMS
371 SECTION 634 (IFGS) CHIMNEY DAMPER OPENING AREA
TABLE 634.1 FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING FLUE GASES FROM UNLISTED DECORATIVE APPLIANCES FOR INSTALLATION IN VENTED FIREPLACES
SECTION 635 (IFGC) GASEOUS HYDROGEN SYSTEMS
SECTION 636 (IFGC) OUTDOOR DECORATIVE APPLIANCES
FIGURE 636.1 OUTDOOR (CAMPFIRE) DECORATIVE APPLIANCE
372 BIBLIOGRAPHY
374 CHAPTER 7: GASEOUS HYDROGEN SYSTEMS
GENERAL COMMENTS
FIGURE 700(1) ELECTROLYSIS OF WATER
PURPOSE
375 FIGURE 700(2) FUEL CELL PRINCIPLE OF OPERATION
FIGURE 700(3) FUEL CELL PRINCIPLE OF OPERATION
376 SECTION 701 (IFGC) GENERAL
SECTION 702 (IFGC) GENERAL DEFINITIONS
SECTION 703 (IFGC) GENERAL REQUIREMENTS
377 FIGURE 702.1 HYDROGEN-GENERATING APPLIANCE
379 SECTION 704 (IFGC) PIPING, USE AND HANDLING
382 SECTION 705 (IFGC) TESTING OF HYDROGEN PIPING SYSTEMS
384 SECTION 706 (IFGC) LOCATION OF GASEOUS HYDROGEN SYSTEMS
SECTION 707 (IFGC) OPERATION AND MAINTENANCE OF GASEOUS HYDROGEN SYSTEMS
385 SECTION 708 (IFGC) DESIGN OF LIQUEFIED HYDROGEN SYSTEMS ASSOCIATED WITH HYDROGEN VAPORIZATION OPERATIONS
BIBLIOGRAPHY
386 CHAPTER 8: REFERENCED STANDARDS
GENERAL COMMENTS
PURPOSE
387 FIGURE 800 REFERENCED STANDARDS
388 ANSI
389 ASME
ASTM
CGA
390 CSA
DOTn
ICC
MSS
391 NFPA
UL
392 APPENDIX A (IFGS): SIZING AND CAPACITIES OF GAS PIPING
A.1 GENERAL PIPING CONSIDERATIONS
A.2 DESCRIPTION OF TABLES
393 TABLE A.2.2 EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
394 TABLE A.2.2—continued EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
395 TABLE A.2.4 MULTIPLIERS TO BE USED WITH TABLES 402.4(1) THROUGH 402.4(22) WHERE THE SPECIFIC GRAVITY OF THE GAS IS OTHER THAN 0.60
A.3 USE OF CAPACITY TABLES
397 TABLE A.3.4 THOUSANDS OF BTU/H (MBH) OF NATURAL GAS PER 100 FEET OF PIPE AT VARIOUS PRESSURE DROPS AND PIPE DIAMETERS
A.4 USE OF SIZING EQUATIONS
A.5 PIPE AND TUBE DIAMETERS
398 TABLE A.5.1 SCHEDULE 40 STEEL PIPE STANDARD SIZES
TABLE A.5.2 COPPER TUBE STANDARD SIZES
A.6 EXAMPLES OF PIPING SYSTEM DESIGN AND SIZING
399 FIGURE A.6.1 PIPING PLAN SHOWING A STEEL PIPING SYSTEM
FIGURE A.6.2 PIPING PLAN SHOWING A CSST SYSTEM
400 FIGURE A.6.3 PIPING PLAN SHOWING A COPPER TUBING SYSTEM
401 FIGURE A.6.4 PIPING PLAN SHOWING A MODIFICATION TO EXISTING PIPING SYSTEM
402 APPENDIX B (IFGS): SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS
EXAMPLES USING SINGLE APPLIANCE VENTING TABLES
FIGURE B-1 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A TYPE B DOUBLE-WALL VENT
FIGURE B-2 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A SINGLE-WALL METAL VENT CONNECTOR
403 FIGURE B-3 VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A MASONRY CHIMNEY OF TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-4 VENT SYSTEM SERVING A SINGLE APPLIANCE USING A MASONRY CHIMNEY AND A SINGLE-WALL METAL VENT CONNECTOR
FIGURE B-5 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING A SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-6 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND TYPE BDOUBLE-WALL VENT CONNECTOR
404 FIGURE B-7 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-8 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-9 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-10 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING TWO OR MORE DRAFT-HOOD-EQUIPPED APPLIANCES
405 FIGURE B-11 USE OF MANIFOLD COMMON VENT CONNECTOR
FIGURE B-12 USE OF OFFSET COMMON VENT
FIGURE B-13 MULTISTORY GAS VENT DESIGN PROCEDURE FOR EACH SEGMENT OF SYSTEM
FIGURE B-14 MULTISTORY VENT SYSTEMS
406 FIGURE B-15 (EXAMPLE 1) SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-16 (EXAMPLE 2) SINGLE FAN-ASSISTED APPLIANCE
407 EXAMPLES USING COMMON VENTING TABLES
FIGURE B-17 (EXAMPLE 4) COMMON VENTING TWO DRAFTHOOD-EQUIPPED APPLIANCES
FIGURE B-18 (EXAMPLE 5A) COMMON VENTING A DRAFT HOOD WITH A FAN-ASSISTED FURNACE INTO A TYPE B DOUBLE-WALL COMMON VENT
409 TABLE B-1 MASONRY CHIMNEY LINER DIMENSIONS WITH CIRCULAR EQUIVALENTS
410 FIGURE B-19
412 APPENDIX C (IFGS): EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
FIGURE: APPENDIX C EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
414 APPENDIX D (IFGS): RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION
D.1 GENERAL
D.2 OCCUPANT AND INSPECTOR SAFETY
415 D.3 GAS PIPING AND CONNECTION INSPECTIONS
D.4 INSPECTIONS TO BE PERFORMED WITH APPLIANCE NOT OPERATING
416 D.5 INSPECTIONS TO BE PERFORMED WITH THE APPLIANCE OPERATING
417 D.6 APPLIANCE-SPECIFIC INSPECTIONS
419 TABLE D.6 CO THRESHOLDS
420 INDEX
424 2015 I-CODE ESSENTIALS
425 ICC TRAINING AND EDUCATION DEPARTMENT
426 GET IMMEDIATE DOWNLOADS OF THE STANDARDS YOU NEED
427 VALUABLE GUIDES TO CHANGES IN THE 2015 I-CODES
ICC IFGC Commentary 2015
$80.71