IFGC 12:2012 Edition

$45.77

International Fuel Gas Code

Published By Publication Date Number of Pages
ICC 2012 185
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Addresses the design and installation of fuel gas systems and gas fired appliances through requirements that emphasize performance. Changes include:

  • All piping, tubing and fittings in a fuel gas system must bear the manufacturer’s identification.
  • Clarification that gypsum board requires reduced clearances to combustibles the same as any other combustible material.
  • Requirement of flashback arrestors and check valves in fuel gas systems used with oxygen.

PDF Catalog

PDF Pages PDF Title
1 2012 INTERNATIONAL FUEL GAS CODE®
2 2012 INTERNATIONAL FUEL GAS CODE® IFGC® TITLE PAGE
3 COPYRIGHT
4 PREFACE
8 EFFECTIVE USE OF THE INTERNATIONAL FUEL GAS CODE
10 LEGISLATION
12 TABLE OF CONTENTS
14 CHAPTER 1 SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION 101 (IFGC) GENERAL
15 SECTION 102 (IFGC) APPLICABILITY
PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION 103 (IFGC) DEPARTMENT OF INSPECTION
16 SECTION 104 (IFGC) DUTIES AND POWERS OF THE CODE OFFICIAL
SECTION 105 (IFGC) APPROVAL
17 SECTION 106 (IFGC) PERMITS
18 SECTION 107 (IFGC) INSPECTIONS AND TESTING
20 SECTION 108 (IFGC) VIOLATIONS
SECTION 109 (IFGC) MEANS OF APPEAL
21 SECTION 110 (IFGC) TEMPORARY EQUIPMENT, SYSTEMS AND USES
22 CHAPTER 2 DEFINITIONS
SECTION 201 (IFGC) GENERAL
SECTION 202 (IFGC) GENERAL DEFINITIONS
30 CHAPTER 3 GENERAL REGULATIONS
SECTION 301 (IFGC) GENERAL
31 SECTION 302 (IFGC) STRUCTURAL SAFETY
SECTION 303 (IFGC) APPLIANCE LOCATION
32 SECTION 304 (IFGS) COMBUSTION, VENTILATION AND DILUTION AIR
EQUATION 3-1
EQUATION 3-2
33 FIGURE 304.5.3 ALL AIR FROM INSIDE THE BUILDING (see Section 304.5.3)
FIGURE 304.6.1(1) ALL AIR FROM OUTDOORS—INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC (see Section 304.6.1)
FIGURE 304.6.1(2) ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC (see Section 304.6.1)
34 FIGURE 304.6.1(3) ALL AIR FROM OUTDOORS (see Section 304.6.1)
FIGURE 304.6.2 SINGLE COMBUSTION AIR OPENING,ALL AIR FROM THE OUTDOORS (see Section 304.6.2)
35 SECTION 305 (IFGC) INSTALLATION
36 SECTION 306 (IFGC) ACCESS AND SERVICE SPACE
38 SECTION 307 (IFGC) CONDENSATE DISPOSAL
SECTION 308 (IFGS) CLEARANCE REDUCTION
39 TABLE 308.2 a through k REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTION
SECTION 309 (IFGC) ELECTRICAL
40 FIGURE 308.2(1) EXTENT OF PROTECTION NECESSARY TO REDUCE CLEARANCES FROM APPLIANCE OR VENT CONNECTIONS
FIGURE 308.2(2) WALL PROTECTOR CLEARANCE REDUCTION SYSTEM
FIGURE 308.2(3) MASONRY CLEARANCE REDUCTION SYSTEM
41 SECTION 310 (IFGS) ELECTRICAL BONDING
42 CHAPTER 4 GAS PIPING INSTALLATIONS
SECTION 401 (IFGC) GENERAL
SECTION 402 (IFGS) PIPE SIZING
EQUATION 4-1
43 EQUATION 4-2
TABLE 402.4 Cr AND Y VALUES FOR NATURAL GAS AND UNDILUTED PROPANE AT STANDARD CONDITIONS
TABLE 402.2 APPROXIMATE GAS INPUT FOR TYPICAL APPLIANCES
44 TABLE 402.4(1) SCHEDULE 40 METALLIC PIPE
45 TABLE 402.4(2) SCHEDULE 40 METALLIC PIPE
46 TABLE 402.4(3) SCHEDULE 40 METALLIC PIPE
47 TABLE 402.4(4) SCHEDULE 40 METALLIC PIPE
48 TABLE 402.4(5) SCHEDULE 40 METALLIC PIPE
49 TABLE 402.4(6) SCHEDULE 40 METALLIC PIPE
50 TABLE 402.4(7) SCHEDULE 40 METALLIC PIPE
51 TABLE 402.4(8) SEMIRIGID COPPER TUBING
52 TABLE 402.4(9) SEMIRIGID COPPER TUBING
53 TABLE 402.4(10) SEMIRIGID COPPER TUBING
54 TABLE 402.4(11) SEMIRIGID COPPER TUBING
55 TABLE 402.4(12) SEMIRIGID COPPER TUBING
56 TABLE 402.4(13) SEMIRIGID COPPER TUBING
57 TABLE 402.4(14) SEMIRIGID COPPER TUBING
58 TABLE 402.4(15) CORRUGATED STAINLESS STEEL TUBING (CSST)
59 TABLE 402.4(16) CORRUGATED STAINLESS STEEL TUBING (CSST)
60 TABLE 402.4(17) CORRUGATED STAINLESS STEEL TUBING (CSST)
61 TABLE 402.4(18) CORRUGATED STAINLESS STEEL TUBING (CSST)
62 TABLE 402.4(19) CORRUGATED STAINLESS STEEL TUBING (CSST)
63 TABLE 402.4(20) POLYETHYLENE PLASTIC PIPE
64 TABLE 402.4(21) POLYETHYLENE PLASTIC PIPE
65 TABLE 402.4(22) POLYETHYLENE PLASTIC PIPE
66 TABLE 402.4(23) POLYETHYLENE PLASTIC TUBING
TABLE 402.4(24) POLYETHYLENE PLASTIC TUBING
67 TABLE 402.4(25) SCHEDULE 40 METALLIC PIPE
68 TABLE 402.4(26) SCHEDULE 40 METALLIC PIPE
69 TABLE 402.4(27) SCHEDULE 40 METALLIC PIPE
70 TABLE 402.4(28) SCHEDULE 40 METALLIC PIPE
71 TABLE 402.4(29) SEMIRIGID COPPER TUBING
72 TABLE 402.4(30) SEMIRIGID COPPER TUBING
73 TABLE 402.4(31) SEMIRIGID COPPER TUBING
74 TABLE 402.4(32) CORRUGATED STAINLESS STEEL TUBING (CSST)
75 TABLE 402.4(33) CORRUGATED STAINLESS STEEL TUBING (CSST)
76 TABLE 402.4(34) CORRUGATED STAINLESS STEEL TUBING (CSST)
77 TABLE 402.4(35) POLYETHYLENE PLASTIC PIPE
78 TABLE 402.4(36) POLYETHYLENE PLASTIC PIPE
79 TABLE 402.4(37) POLYETHYLENE PLASTIC TUBING
80 SECTION 403 (IFGS) PIPING MATERIALS
81 TABLE 403.9.2 SPECIFICATIONS FOR THREADING METALLIC PIPE
82 SECTION 404 (IFGC) PIPING SYSTEM INSTALLATION
84 SECTION 405 (IFGS) PIPING BENDS AND CHANGES IN DIRECTION
SECTION 406 (IFGS) INSPECTION, TESTING AND PURGING
86 TABLE 406.7.1.1 SIZE AND LENGTH OF PIPING
87 SECTION 407 (IFGC) PIPING SUPPORT
SECTION 408 (IFGC) DRIPS AND SLOPED PIPING
FIGURE 408.4 METHOD OF INSTALLING A TEE FITTING SEDIMENT TRAP
SECTION 409 (IFGC) SHUTOFF VALVES
TABLE 409.1.1 MANUAL GAS VALVE STANDARDS
88 SECTION 410 (IFGC) FLOW CONTROLS
89 SECTION 411 (IFGC) APPLIANCE AND MANUFACTURED HOME CONNECTIONS
90 SECTION 412 (IFGC) LIQUEFIED PETROLEUM GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES
SECTION 413 (IFGC) COMPRESSED NATURAL GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES
92 [F] TABLE 413.9.2.3 SEPARATION DISTANCE FOR ATMOSPHERIC VENTING OF CNG
SECTION 414 (IFGC) SUPPLEMENTAL AND STANDBY GAS SUPPLY
SECTION 415 (IFGS) PIPING SUPPORT INTERVALS
TABLE 415.1 SUPPORT OF PIPING
SECTION 416 (IFGS) OVERPRESSURE PROTECTION DEVICES
96 CHAPTER 5 CHIMNEYS AND VENTS
SECTION 501 (IFGC) GENERAL
97 SECTION 502 (IFGC) VENTS
98 SECTION 503 (IFGS) VENTING OF APPLIANCES
99 TABLE 503.4 TYPE OF VENTING SYSTEM TO BE USED
101 FIGURE 503.6.4 TERMINATION LOCATIONS FOR GAS VENTS WITH LISTED CAPS 12 INCHES OR LESS IN SIZE AT LEAST 8 FEET FROM A VERTICAL WALL
104 TABLE 503.10.2.4 MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES
TABLE 503.10.2.5 MINIMUM THICKNESS FOR STEEL VENT CONNECTORS FOR MEDIUM-HEAT APPLIANCES
105 TABLE 503.10.5a CLEARANCES FOR CONNECTORS
107 SECTION 504 (IFGS) SIZING OF CATEGORY I APPLIANCE VENTING SYSTEMS
109 TABLE 504.3.2 MAXIMUM VENT CONNECTOR LENGTH
111 SECTION 505 (IFGC) DIRECT-VENT, INTEGRAL VENT, MECHANICAL VENT AND VENTILATION/EXHAUST HOOD VENTING
SECTION 506 (IFGC) FACTORY-BUILT CHIMNEYS
112 TABLE 504.2(1) TYPE B DOUBLE-WALL GAS VENT
113 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
114 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
115 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
116 TABLE 504.2(2) TYPE B DOUBLE-WALL GAS VENT
117 TABLE 504.2(2)-continued TYPE B DOUBLE-WALL GAS VENT
118 TABLE 504.2(3) MASONRY CHIMNEY
119 TABLE 504.2(3)—continued MASONRY CHIMNEY
120 TABLE 504.2(4) MASONRY CHIMNEY
121 TABLE 504.2(4)—continued MASONRY CHIMNEY
122 TABLE 504.2(5) SINGLE-WALL METAL PIPE OR TYPE B ASBESTOS CEMENT VENT
123 TABLE 504.2(6) EXTERIOR MASONRY CHIMNEY
124 TABLE 504.3(1) TYPE B DOUBLE-WALL VENT
125 TABLE 504.3(1)-continued TYPE B DOUBLE-WALL VENT
126 TABLE 504.3(2) TYPE B DOUBLE-WALL VENT
127 TABLE 504.3(3) MASONRY CHIMNEY
128 TABLE 504.3(4) MASONRY CHIMNEY
129 TABLE 504.3(5) SINGLE-WALL METAL PIPE OR TYPE ASBESTOS CEMENT VENT
130 TABLE 504.3(6a) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(6b) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(6b) EXTERIOR MASONRY CHIMNEY-continued
131 TABLE 504.3(7a) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(7b) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(7b) EXTERIOR MASONRY CHIMNEY—continued
132 CHAPTER 6 SPECIFIC APPLIANCES
SECTION 601 (IFGC) GENERAL
SECTION 602 (IFGC) DECORATIVE APPLIANCES FOR INSTALLATION IN FIREPLACES
SECTION 603 (IFGC) LOG LIGHTERS
SECTION 604 (IFGC) VENTED GAS FIREPLACES (DECORATIVE APPLIANCES)
SECTION 605 (IFGC) VENTED GAS FIREPLACE HEATERS
SECTION 606 (IFGC) INCINERATORS AND CREMATORIES
SECTION 607 (IFGC) COMMERCIAL-INDUSTRIAL INCINERATORS
SECTION 608 (IFGC) VENTED WALL FURNACES
133 SECTION 609 (IFGC) FLOOR FURNACES
SECTION 610 (IFGC) DUCT FURNACES
SECTION 611 (IFGC) NONRECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS
134 SECTION 612 (IFGC) RECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS
SECTION 613 (IFGC) CLOTHES DRYERS
SECTION 614 (IFGC) CLOTHES DRYER EXHAUST
135 [M] TABLE 614.6.5.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH
136 SECTION 615 (IFGC) SAUNA HEATERS
SECTION 616 (IFGC) ENGINE AND GAS TURBINE-POWERED EQUIPMENT
137 SECTION 617 (IFGC) POOL AND SPA HEATERS
SECTION 618 (IFGC) FORCED-AIR WARM-AIR FURNACES
138 SECTION 619 (IFGC) CONVERSION BURNERS
SECTION 620 (IFGC) UNIT HEATERS
SECTION 621 (IFGC) UNVENTED ROOM HEATERS
SECTION 622 (IFGC) VENTED ROOM HEATERS
SECTION 623 (IFGC) COOKING APPLIANCES
139 SECTION 624 (IFGC) WATER HEATERS
SECTION 625 (IFGC) REFRIGERATORS
SECTION 626 (IFGC) GAS-FIRED TOILETS
SECTION 627 (IFGC) AIR-CONDITIONING APPLIANCES
140 SECTION 628 (IFGC) ILLUMINATING APPLIANCES
SECTION 629 (IFGC) SMALL CERAMIC KILNS
141 SECTION 630 (IFGC) INFRARED RADIANT HEATERS
SECTION 631 (IFGC) BOILERS
SECTION 632 (IFGC) EQUIPMENT INSTALLED IN EXISTING UNLISTED BOILERS
SECTION 633 (IFGC) STATIONARY FUEL-CELL POWER SYSTEMS
SECTION 634 (IFGS) CHIMNEY DAMPER OPENING AREA
TABLE 634.1 FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING FLUE GASES FROM UNLISTED DECORATIVE APPLIANCES FOR INSTALLATION IN VENTED FIREPLACES
SECTION 635 (IFGC) GASEOUS HYDROGEN SYSTEMS
SECTION 636 (IFGC) OUTDOOR DECORATIVE APPLIANCES
142 CHAPTER 7 GASEOUS HYDROGEN SYSTEMS
SECTION 701 (IFGC) GENERAL
SECTION 702 (IFGC) GENERAL DEFINITIONS
SECTION 703 (IFGC) GENERAL REQUIREMENTS
143 SECTION 704 (IFGC) PIPING, USE AND HANDLING
144 SECTION 705 (IFGC) TESTING OF HYDROGEN PIPING SYSTEMS
145 SECTION 706 (IFGC) LOCATION OF GASEOUS HYDROGEN SYSTEMS
146 SECTION 707 (IFGC) OPERATION AND MAINTENANCE OF GASEOUS HYDROGEN SYSTEMS
SECTION 708 (IFGC) DESIGN OF LIQUEFIED HYDROGEN SYSTEMS ASSOCIATED WITH HYDROGEN VAPORIZATION OPERATIONS
148 IFGC/IFGS CHAPTER 8 REFERENCED STANDARDS
ANSI
149 ASME
ASTM
CGA
CSA
150 DOTn
ICC
MSS
NFPA
151 UL
152 APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING
A.1 GENERAL PIPING CONSIDERATIONS
A.2 DESCRIPTION OF TABLES
153 TABLE A.2. 2EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
154 TABLE A.2.2—continued EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
155 TABLE A.2.4 MULTIPLIERS TO BE USED WITH TABLES 402.4(1) THROUGH 402.4(22) WHERE THE SPECIFIC GRAVITY OF THE GAS IS OTHER THAN 0.60
A.3 USE OF CAPACITY TABLES
157 TABLE A.3.4 THOUSANDS OF BTU/H (MBH) OF NATURAL GAS PER 100 FEET OF PIPE AT VARIOUS PRESSURE DROPS AND PIPE DIAMETERS
A.4 USE OF SIZING EQUATIONS
158 A.5 PIPE AND TUBE DIAMETERS
TABLE A.5.1 SCHEDULE 40 STEEL PIPE STANDARD SIZES
TABLE A.5.2 COPPER TUBE STANDARD SIZES
A.6 USE OF SIZING CHARTS
159 FIGURE A.6(a) CAPACITY OF NATURAL GAS PIPING, LOW PRESSURE (0.60 WC)
A.7 EXAMPLES OF PIPING SYSTEM DESIGN AND SIZING
FIGURE A.7.1 PIPING PLAN SHOWING A STEEL PIPING SYSTEM
160 FIGURE A.6(b) CAPACITY OF NATURAL GAS PIPING, HIGH PRESSURE (1.5 psi and above)
161 FIGURE A.7.2 PIPING PLAN SHOWING A CSST SYSTEM
162 FIGURE A.7.3 PIPING PLAN SHOWING A COPPER TUBING SYSTEM
FIGURE A.7.4 PIPING PLAN SHOWING A MODIFICATION TO EXISTING PIPING SYSTEM
164 APPENDIX B (IFGS) SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS
EXAMPLES USING SINGLE APPLIANCE VENTING TABLES
FIGURE B-1 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A TYPE B DOUBLE-WALL VENT
FIGURE B-2 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A SINGLE-WALL METAL VENT CONNECTOR
165 FIGURE B-3 VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A MASONRY CHIMNEY OF TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-4 VENT SYSTEM SERVING A SINGLE APPLIANCE USING A MASONRY CHIMNEY AND A SINGLE-WALL METAL VENT CONNECTOR
FIGURE B-5 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING A SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-6 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND TYPE B DOUBLE-WALL VENT CONNECTOR
166 FIGURE B-7 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-8 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-9 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-10 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING TWO OR MORE DRAFT-HOOD-EQUIPPED APPLIANCES
167 FIGURE B-11 USE OF MANIFOLD COMMON VENT CONNECTOR
FIGURE B-12 USE OF OFFSET COMMON VENT
FIGURE B-13 MULTISTORY GAS VENT DESIGN PROCEDURE FOR EACH SEGMENT OF SYSTEM
FIGURE B-14 MULTISTORY VENT SYSTEMS
168 FIGURE B-15 (EXAMPLE 1) SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-16 (EXAMPLE 2) SINGLE FAN-ASSISTED APPLIANCE
169 EXAMPLES USING COMMON VENTING TABLES
FIGURE B-17 (EXAMPLE 4) COMMON VENTING TWO DRAFT HOOD-EQUIPPED APPLIANCES
FIGURE B-18 (EXAMPLE 5A) COMMON VENTING A DRAFT HOOD WITH A FAN-ASSISTED FURNACE INTO A TYPE B DOUBLE-WALL COMMON VENT
171 TABLE B-1 MASONRY CHIMNEY LINER DIMENSIONS WITH CIRCULAR EQUIVALENTSa
172 FIGURE B-19
174 APPENDIX C (IFGS) EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
APPENDIX C EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
176 APPENDIX D (IFGS) RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION
178 INDEX
182 ICC MEMBERSHIP
183 ICC-ES ICC EVALUATION SERVICES PMG PROGRAM
184 LEARN AND APPLY PLUMBING, MECHANICAL, AND FUEL GAS CODES
185 VALUABLE GUIDES TO CHANGES IN THE 2012 I-CODES®
IFGC 12