Shopping Cart

No products in the cart.

IEC 62439-1:2010

$88.40

Industrial communication networks – High availability automation networks – Part 1: General concepts and calculation methods

Published By Publication Date Number of Pages
IEC 2010-02-25 114
Guaranteed Safe Checkout
Categories: , ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC 62439-1:2010 is applicable to high-availability automation networks based on the ISO/IEC 8802-3 (IEEE 802.3) (Ethernet) technology. It specifies:
– the common elements and definitions for other parts of the IEC 62439 series;
– the conformance test specification (normative);
– a classification scheme for network characteristics (informative);
– a methodology for estimating network availability (informative);
– the configuration rules, calculation and measurement method for a deterministic recovery time in RSTP. This standard cancels and replaces IEC 62439 published in 2008 and constitutes a technical revision. It includes the following changes:
– a new calculation method for RSTP (rapid spanning tree protocol, IEEE 802.1Q),
– two new redundancy protocols: HSR (High-availability Seamless Redundancy) and DRP (Distributed Redundancy Protocol),
– a new method to calculate the maximum recovery time of RSTP in a restricted configuration (ring) to IEC 62439-1 as Clause 8, new specifications of the HSR (High-availability Seamless Redundancy) protocol, which shares the principles of PRP to IEC 62439-3 as Clause 5, and
– introduces the DRP protocol as IEC 62439-6. This bilingual version (2013-07) corresponds to the monolingual English version, published in 2010-02.

IEC 62439-1:2010
$88.40