Shopping Cart

No products in the cart.

IEEE 515 2011

$57.42

IEEE Standard for the Testing, Design, Installation, and Maintenance of Electrical Resistance Trace Heating for Industrial Applications

Published By Publication Date Number of Pages
IEEE 2011 91
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Revision Standard – Active. Specific testing requirements for qualifying electrical resistance heating cables and heating devices for use in industrial applications, as well as a basis for electrical and thermal design, are included in this standard. Unclassified applications and explosive atmosphere applications that use both Divisions and Zone methods of classification are included.

PDF Catalog

PDF Pages PDF Title
1 IEEE Std 515-2011 Front Cover
3 Title Page
6 Introduction
Notice to users
Laws and regulations
Copyrights
7 Updating of IEEE documents
Errata
Interpretations
Patents
8 Participants
10 Contents
13 Important Notice
1. Overview
1.1 Scope
1.2 Purpose
14 2. Normative references
3. Definitions
17 4. General product testing
4.1 Type test—general purpose tests
27 4.2 Type test—verification of sheath temperatures
32 4.3 Specific type test requirements for hazardous (classified) locations
34 4.4 Routine tests
35 5. Marking and installation instructions
5.1 Product markings for heating devices
5.2 Markings for field-assembled components
36 5.3 Installation instructions
6. Design
6.1 Process considerations
37 6.2 Environmental/site considerations
38 6.3 Thermal insulation and heat-loss considerations
42 6.4 Maximum temperature determination
47 6.5 Design parameters
48 6.6 Design information
49 6.7 Power system
51 6.8 Special considerations
56 6.9 Controlling and monitoring considerations
59 6.10 Division 1 and Zone 1 design requirements
6.11 Safety shower design requirements
60 7. Installation
7.1 Personnel
7.2 Receiving and storage of materials
61 7.3 Scheduling of installation
7.4 General installation recommendations
63 7.5 Special Division 1 and Zone 1 installation requirements
64 7.6 Controls and sensors
65 7.7 Testing after installation
7.8 Thermal insulation—recommendations
66 7.9 Functional check and field documentation—recommendations
8. Maintenance
8.1 General maintenance recommendations
67 8.2 Division 1/Zone 1 maintenance recommendations
8.3 Visual inspection
8.4 Periodic operational check
68 8.5 Record keeping
69 Annex A (informative) Bibliography
71 Annex B (informative) Pipe heat-loss considerations
77 Annex C (informative) Vessel heat-loss considerations
81 Annex D (informative) Heat-up and cool-down considerations
84 Annex E (informative) Method to determine equivalent thicknesses of insulating cements
85 Annex F (informative) Type test matrix for Clause 4
87 Annex G (informative) Design basic data—example (see 6.6)
88 Annex H (informative) Trace heater installation record—example (see 7.2.2)
89 Annex I (normative) Division 1/Zone 1—checklist example (see 7.5)
90 Annex J (informative) Trace heater commissioning record—example (see 7.9)
91 Annex K (informative) Maintenance log record—example (see 8.5.3)
IEEE 515 2011
$57.42