Shopping Cart

No products in the cart.

IEEE C37.43-2008

$49.83

IEEE Standard Specifications for High-Voltage Expulsion, Current-Limiting, and Combination-Type Distribution and Power Class External Fuses, with Rated Voltages from 1 kV through 38 kV, Used for the Protection of Shunt Capacitors

Published By Publication Date Number of Pages
IEEE 2008
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

New IEEE Standard – Superseded. This standard establishes specifications for high-voltage (above 1000 V) distribution and power class expulsion, current-limiting, and combination-type external capacitor fuses and accessories, with rated voltages from 1 kV through 38 kV, for protecting shunt capacitors complying with IEEE Std 18-2002 and NEMA CP 1-2000. All of these devices are intended for use on ac systems. These fuses may be used with capacitor units, groups of units, or entire banks and include specific capacitor line [group] and capacitor unit fuse types as follows: a) Current-limiting fuses; b) Expulsion fuses; c) Combination of current-limiting and expulsion fuses; d) Fuse supports, fuse mountings, and accessories used with fuses of type a), type b), and type c); and e) Current-limiting, expulsion, and combination-type capacitor fuses [type a), type b), and type c), respectively] used in fuse enclosure packages (FEPs). (Superseded by IEEE C37.42-2016.)

PDF Catalog

PDF Pages PDF Title
1 IEEE Std C37.43™-2008 Front cover
3 Title page
6 Introduction
7 Notice to users
Laws and regulations
Copyrights
Updating of IEEE documents
Errata
Interpretations
8 Patents
Participants
10 Contents
11 Important notice
1. Overview
1.1 Scope
12 1.2 Background
2. Normative references
13 3. General rating information
3.1 Ratings of capacitor fuse supports
14 3.2 Ratings of fuseholders, fuses, fuse units, refill units, and fuse links for capacitor fuses
3.3 Preferred ratings and performance requirements
18 4. Design test requirements
4.1 Dielectric tests
4.2 Interrupting [breaking] tests
19 4.3 Radio-influence tests
4.4 Temperature-rise tests
4.5 Time-current tests
20 5. Time-current-characteristic requirements for capacitor fuse refill units, fuse units, and fuse links
5.1 General
5.2 Melting current tolerance
6. Conformance test requirements for capacitor fuses
7. Construction requirements for capacitor fuses
8. Nameplate marking requirements
8.1 Fuses, fuse units, and fuseholders for capacitor fuses
21 8.2 Fuse links and refill units
8.3 Fuse supports
8.4 Additional information
9. Application requirements
22 Annex A (informative) Bibliography