Shopping Cart

No products in the cart.

IEEE C63.10 2009

$58.50

American National Standard for Testing Unlicensed Wireless Devices

Published By Publication Date Number of Pages
IEEE 2009 131
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

– Active. This standard is intended to cover procedures for testing the compliance of a wide variety of unlicensed wireless devices (also called unlicensed intentional radiators) including but not limited to: remote control and security unlicensed wireless devices, frequency hopping and direct sequence spread spectrum devices, anti-pilferage devices, cordless telephones, wireless medical unlicensed wireless devices, Unlicensed National Information Infrastructure devices, intrusion detectors, unlicensed wireless devices operating on frequencies below 30 MHz, automatic vehicle identification systems, and other unlicensed wireless devices authorized by a radio regulatory authority. The test procedures for new technology wireless devices will be added to future editions of this standard as soon as practical after consensus is achieved for compliance testing methods of the new devices. However, this standard excludes test procedures for unlicensed wireless devices already covered in other published standards, e.g., Unlicensed Personal Communication Services (UPCS) devices.

PDF Catalog

PDF Pages PDF Title
1 ANSI C63.10-2009 Front Cover
3 Title page
6 Introduction
Notice to users
Laws and regulations
Copyrights
Updating of IEEE documents
7 Errata
Interpretations
Patents
8 Participants
10 CONTENTS
13 Important Notice
1. Overview
1.1 Scope
14 1.2 Purpose
15 2. Normative references
16 3. Definitions and acronyms
3.1 Definitions
17 3.2 Acronyms
19 4. Measurement instrumentation
4.1 General considerations
4.2 Emission measuring instrumentation
4.2.1 Receiver
4.2.2 Spectrum analyzer
21 4.2.3 Detector functions and selection of bandwidth
23 4.2.4 Signal monitoring
4.3 Line impedance stabilization network (LISN)
25 4.4 Voltage probe
26 4.5 Antennas
27 4.5.1 Magnetic field measurements (9 kHz to 30 MHz)
4.5.2 Electric field measurements (30 MHz to 1000 MHz)
4.5.3 Electric field measurements (above 1 GHz)
4.6 Calibration of measuring equipment
4.6.1 Confirmation interval
28 4.6.2 Antenna calibration
4.6.3 LISN impedance and insertion loss measurements
4.6.4 Cable insertion loss
29 5. General measurement and setup considerations
5.1 General requirements
5.2 Radiated emission test site
5.3 Radiated emission test distance
5.3.1 Test distance for frequencies at or above 30 MHz
30 5.3.2 Test distance for frequencies below 30 MHz
5.4 Measurements around the EUT
5.5 Frequency range of radiated emission measurements
31 5.6 Number of fundamental frequencies to be tested in EUT transmit band
5.7 Swept-frequency device measurements
5.8 EUT antenna requirements
5.9 Restricted frequency bands of operation
32 5.10 General unlicensed wireless device configurations and test setups
5.10.1 Stand-alone unlicensed wireless devices
5.10.2 Modular unlicensed wireless devices
5.10.3 Module-like unlicensed wireless device embedded in a host device
33 5.10.4 Unlicensed wireless transmission systems with external antennas
5.10.5 Software requirements for specific unlicensed wireless devices
5.10.6 Maximization of EUT controls
5.10.7 Composite systems
34 5.10.8 External accessories
5.10.9 Central control units
5.11 Operational requirements during testing
35 5.12 Applied modulation
5.13 Variations in supply voltage
5.14 Special accessories
36 6. Standard test methods
6.1 General
6.2 Standard test method for AC power-line conducted emissions from unlicensed wireless devices
6.2.1 General considerations
6.2.2 Measurement requirements
37 6.2.3 Arrangement of EUT
40 6.2.4 Exploratory ac power-line conducted emission measurements
6.2.5 Final ac power-line conducted emission measurements
41 6.3 Radiated emissions testing—general requirements
6.3.1 Radiated total peak emission level
6.3.2 Radiated spurious emissions testing including unlicensed wireless device harmonics
6.3.3 Unlicensed wireless device operational configuration
42 6.3.4 Test setup
6.4 Standard test method for radiated emissions from unlicensed wireless devices below 30 MHz
6.4.1 General testing requirements
43 6.4.2 Antenna selection, location, and test distance
6.4.3 Equipment arrangement
6.4.4 Radiated emission test procedure
44 6.4.5 Test reporting
6.5 Standard test method for radiated emissions from unlicensed wireless devices in the frequency range of 30 MHz to 1000 MHz
6.5.1 General test requirements
45 6.5.2 Equipment arrangement
6.5.3 Antenna selection, location and test distance
6.5.4 Radiated emission test procedure
47 6.5.5 Test reporting
6.6 Standard test method for radiated emissions from unlicensed wireless devices above 1 GHz
6.6.1 General test requirements
48 6.6.2 Antenna selection, location and measuring distance
6.6.3 Equipment arrangement
6.6.4 Radiated emissions tests
51 6.6.5 Reporting of test data
6.7 Antenna-port conducted emission measurements
6.8 Frequency stability tests
6.8.1 Frequency stability with respect to ambient temperature
52 6.8.2 Frequency stability when varying supply voltage
53 6.9 Occupied bandwidth and band-edge tests
6.9.1 Occupied bandwidth testing
54 6.9.2 Band-edge testing
55 6.9.3 Marker-delta method for band-edge measurements
56 6.9.4 Band edge data reporting requirements
6.10 Output power testing for certain unlicensed wireless devices
6.10.1 Output power test procedure for frequency-hopping spread-spectrum (FHSS) devices
6.10.2 Output power test procedure for digital transmission system (DTS) devices
57 6.10.3 Output power for Unlicensed National Information Infrastructure (U-NII) band devices
60 6.10.4 Peak excursion measurement for U-NII devices
6.11 Power spectral density measurements for frequencies below 40 GHz
61 6.11.1 Peak power spectral density (PPSD) for U-NII devices
62 6.11.2 Power spectral density testing for DTS devices
64 6.12 On-site (in-situ) radiated emission measurements
6.12.1 In-situ measurements for frequencies below 30 MHz
65 6.12.2 In-situ measurements for frequencies above 30 MHz
6.12.3 On-site ac power-line conducted measurements
6.12.4 Other on-site measurements
6.13 Figures for Clause 6
70 7. Additional tests and requirements for specific devices
7.1 Test method for determining compliance of cordless telephone handset security code
71 7.2 Frequency pairing for cordless phones
7.2.1 Requirements
7.2.2 Reporting
7.3 Input power to final RF stage for unlicensed wireless devices
72 7.4 Procedure for determining compliance of unlicensed wireless device with periodic operation
7.5 Procedure for determining the average value of pulsed emissions
73 7.6 Evaluation of certain unlicensed wireless devices with periodic emissions against limits
74 7.6.1 Determination of spurious and fundamental emissions
7.6.2 Calculation of the limit
7.6.3 Example of calculation of emission from a pulse-modulated unlicensed wireless device
76 7.7 Evaluation of frequency-hopping device parameters
7.7.1 Test setup
7.7.2 Carrier frequency separation
7.7.3 Number of hopping frequencies
77 7.7.4 Time of occupancy (dwell time)
7.7.5 Pseudorandom frequency-hopping sequence
7.7.6 Equal hopping frequency usage
7.7.7 System receiver input bandwidth
7.7.8 Reporting requirements
78 7.7.9 Band-edge measurements for RF conducted emissions
7.7.10 Conducted spurious emissions test methodology
7.8 Procedures for testing millimeter wave systems
7.8.1 General information
79 7.8.2 Calculation of the peak output power of the EUT
80 7.8.3 Calculation of peak power density of an emission
81 7.8.4 Measurement instrumentation
7.8.5 Emission bandwidth measurement procedures and test setup for millimeter wave devices
82 7.8.6 Field-strength measurement procedures for millimeter wave devices
83 7.8.7 Frequency stability instrumentation and measurement procedures for millimeter wave devices
7.9 Evaluation of transmitter etiquette
84 7.9.1 Requirements
7.9.2 Verification
7.9.3 Reporting
7.10 Procedures for measuring ultra-wideband (UWB) devices
7.10.1 Evaluation of –10 dB bandwidth
85 7.10.2 Radiated measurement procedure below 960 MHz
86 7.10.3 Radiated measurement procedure above 960 MHz
88 7.11 Figures for Clause 7
91 8. Test reports
93 Annex A (informative) Example regulatory requirements and associated test methods for unlicensed wireless devices
99 Annex B (informative) Example test report contents template
B.1 Example EUT and test purpose executive summary
100 B.2 Manufacturer’s statement/attestation
101 B.3 Sample of test requirements and test methods summary listing
102 B.4 Product description
B.5 Test setup and conditions
B.6 Product modifications
B.7 Test results
B.7.1 Line conducted emission 150 kHz to 30 MHz
B.7.1.1 Requirements
B.7.1.2 Test setup details
B.7.1.3 Test data
B.7.1.4 Test equipment
103 B.7.1.5 Test information
B.7.2 Radiated emissions below 30 MHz
B.7.2.1 Requirements
B.7.2.2 Test setup details
B.7.2.3 Test data
B.7.2.4 Test equipment
B.7.2.5 Test information
104 B.7.3 Radiated emissions measurements 30 MHz to 1000 MHz
B.7.3.1 Requirements
B.7.3.2 Test setup details
B.7.3.3 Test data
B.7.3.4 Test equipment
B.7.3.5 Test information
105 B.7.4 Radiated emissions measurements above 1 GHz
B.7.4.1 Requirements
B.7.4.2 Test setup details
B.7.4.3 Test data
B.7.4.4 Test equipment
B.7.4.5 Test information
106 B.7.5 Frequency stability measurements
B.7.5.1 Requirements
B.7.5.2 Test setup details
B.7.5.3 Test data
B.7.5.4 Test equipment
B.7.5.5 Test information
B.7.6 Occupied bandwidth
B.7.6.1 Requirements
B.7.6.2 Test setup details
B.7.6.3 Test data
107 B.7.6.4 Test equipment
B.7.6.5 Test information
B.7.7 Antenna port conducted output power
B.7.7.1 Requirements
B.7.7.2 Test setup details
B.7.7.3 Test data
B.7.7.4 Test equipment
B.7.7.5 Test information
108 B.7.8 Polar plots—EUT radiation patterns
B.7.8.1 Requirements
B.7.8.2 Test setup details
B.7.8.3 Test data
B.7.8.4 Test equipment
B.7.8.5 Test information
109 Annex C (informative) Pulse desensitization considerations for emission measurements using a spectrum analyzer
C.1 Narrowband emission
110 C.1.1 Pulse desensitization factor αL for line spectrum display
C.2 Broadband emission
112 C.2.1 Pulse desensitization factor αP for pulse spectrum display
C.3 Application procedure
114 Annex D (informative) Detector functions
D.1 Introduction
D.2 Detector types
D.2.1 RMS voltage detector
115 D.2.2 Quasi-peak voltage detector
D.2.2.1 Pulse amplitude response
116 D.2.2.2 Pulse repetition rate response
D.2.3 Peak-voltage detector
D.2.3.1 Direct peak
117 D.2.3.2 Manual slideback peak
D.2.4 Average envelope-voltage detector
D.3 Detector accuracy
D.4 Associated output/display devices
D.4.1 RMS-voltage detector output
D.4.2 Quasi-peak voltage detector output
D.4.3 Peak-voltage detector output
D.4.4 Average-voltage detector output
118 D.4.5 Vd Output
D.5 Comparison of detector functions
119 Annex E (informative) Glossary
128 Additional references for Glossary not listed in Annex F or Clause 2
130 Annex F (informative) Selected background, source material, and additional reading
IEEE C63.10 2009
$58.50