{"id":111244,"date":"2024-10-18T16:08:07","date_gmt":"2024-10-18T16:08:07","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-c37-122-1993\/"},"modified":"2024-10-24T22:00:48","modified_gmt":"2024-10-24T22:00:48","slug":"ieee-c37-122-1993","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-c37-122-1993\/","title":{"rendered":"IEEE C37.122 1993"},"content":{"rendered":"
Revision Standard – Inactive – Superseded. Guidance in the application of relays and relaying schemes for protection against stator ground faults on high-impedance grounded generators is provided.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | Title Page <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1. Overview 2. References <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 3. Definitions <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 4. Service conditions 4.1 Normal service conditions <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 4.2 Special service conditions 4.3 Other conditions that may affect design and application 5. Ratings and requirements 5.1 Equipment ratings <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 5.2 Pressurized bus enclosures and expansion joints 5.2.1 Criteria for enclosure design <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 5.2.2 Supporting structures and platforms 5.2.3 Bus expansion joints 5.3 Cable terminations and future expansion facilities 5.3.1 Cable terminations <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 5.3.2 Future expansion facilities 5.4 Gas system 5.4.1 Gas density 5.4.2 Contacts <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 5.4.3 Calibration 5.4.4 Piping 5.5 Leakage rate 5.6 Grounding 5.6.1 Grounding of enclosures 5.6.2 Grounding of high-voltage circuit 5.7 Seismic requirements 5.8 Type and routing testing 5.8.1 Type tests <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 5.8.2 Routine tests 5.9 Field testing 5.9.1 Mechanical tests–Leakage 5.9.2 Operational tests 5.9.3 Electrical tests <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 5.10 Shipment and storage 5.11 Installation 5.12 GIS nameplates <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 5.12.1 One-line diagram 5.12.2 Ratings <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 5.12.3 Equipment nameplates 5.12.4 Nameplate for high-voltage cable terminations 5.12.5 Insulating gas system 6. Bibliography <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 6.1 Dielectric <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | 6.2 Equipment <\/td>\n<\/tr>\n | ||||||
100<\/td>\n | 6.3 General <\/td>\n<\/tr>\n | ||||||
116<\/td>\n | 6.4 Index of authors <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" IEEE Standard for Gas-Insulated Substations<\/b><\/p>\n |