{"id":197485,"date":"2024-10-19T12:34:12","date_gmt":"2024-10-19T12:34:12","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/asa-s12-57-2011\/"},"modified":"2024-10-25T05:07:47","modified_gmt":"2024-10-25T05:07:47","slug":"asa-s12-57-2011","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/asa\/asa-s12-57-2011\/","title":{"rendered":"ASA S12.57 2011"},"content":{"rendered":"
None<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
13<\/td>\n | 1 Scope 1.1 General 1.2 Types of noise and noise sources 1.3 Test environment 1.4 Measurement uncertainty <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 4 Test environment 4.1 Criterion for acoustic adequacy of test environment 4.2 Criterion for background noise <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 5 Instrumentation and measurement equipment 5.1 General 5.2 Calibration 6 Location, installation and operation of noise source under test 6.1 Source location and installation <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 6.2 Auxiliary equipment 6.3 Operation of source during test 7 Measurement procedure 7.1 General <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 7.2 Characterization of noise source under test 7.3 Locations of the reference sound source <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 7.4 Microphone positions <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 7.5 Measurement of sound pressure levels for a noise source which emits steady or nonsteady \n noise <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 7.6 Measurement of sound pressure levels for a noise source which emits impulsive noise 8 Calculation of sound power levels and sound energy levels 8.1 Corrections for background noise <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 8.2 Mean time-averaged sound pressure levels for a noise source which emits steady or \n non-steady noise <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 8.3 Sound power levels 8.4 Mean single event sound pressure level for a noise source which emits impulsive noise <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 8.5 Sound energy levels 8.6 A-weighted sound power level and A-weighted sound energy level 9 Measurement uncertainty 9.1 Methodology <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 9.2 Determination of .omc <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 9.3 Determination of .R0 <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 9.4 Typical upper bound values of .R0 <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 9.5 Total standard deviation, .tot, and expanded uncertainty, U 10 Information to be recorded 10.1 General ii \u00a9 2011 Acoustical Society of America\u2014All rights reserved. \n 10.2 Noise source under test 10.3 Test environment <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 10.4 Instrumentation 10.5 Acoustic data <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | 11 Test report <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | Annex A (normative) Evaluation of the excess of sound pressure level at a given distance <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | Annex B (informative) Recommendations for the location of the reference sound source and the \n microphones, if only one position is used for the reference sound source B.1 General B.2 Recommendation 1 <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | B.3 Recommendation 2 <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | B.4 Recommendation 3 B.5 Recommendation 4 <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | Annex C (normative) Sound power level and sound energy level under reference meteorological \n conditions <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | Annex D (normative) Calculation of A-weighted sound power levels and A-weighted sound energy levels \n from octave-band levels D.1 A-weighted sound power levels D.2 A-weighted sound energy levels D.3 Values of k and Ck for use in calculations <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | Annex E (informative) Guidance on the development of information on measurement uncertainty E.1 General E.2 Considerations on the total standard deviation, .tot <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | E.3 Considerations on .omc <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | E.4 Considerations on .R0 <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | E.5 Combined standard uncertainty E.6 Measurement uncertainty based on reproducibility data <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" ANSI\/ASA S12.57-2011 \/ ISO 3747:2010 (R2016) American National Standard Acoustics – Determination of sound power levels and sound energy levels of noise sources using sound pressure – Engineering\/survey methods for use in situ in a reverberant environment (a nationally adopted international standard)<\/b><\/p>\n |