{"id":197672,"date":"2024-10-19T12:34:53","date_gmt":"2024-10-19T12:34:53","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ashrae-guideline-0-2019-spanish\/"},"modified":"2024-10-25T05:08:23","modified_gmt":"2024-10-25T05:08:23","slug":"ashrae-guideline-0-2019-spanish","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ashrae\/ashrae-guideline-0-2019-spanish\/","title":{"rendered":"ASHRAE Guideline 0 2019 SPANISH"},"content":{"rendered":"
This is a Spanish translation of Guideline 0-2019, The Commissioning Process.ASHRAE Guideline 0 presents best practices for applying whole-building commissioning (Cx) to facilities. The principles and processes included apply to all phases of new construction and renovation projects and provide a uniform, integrated, and consistent approach to commissioning. ASHRAE Guideline 0 includes the Total Building Commissioning Process (TBCxP) as defined by National Institute of Building Sciences (NIBS) in its Commissioning Process Guideline 0.This 2019 edition of ASHRAE Guideline 0 updates terminology to reflect an evolving whole-building Commissioning Process (Cx) and harmonizes terminology and its usage with that of ASHRAE\/IES Standard 202.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | Directriz ASHRAE 0-2019, El Proceso de Commissioning <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | \u00cdNDICE <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | PR\u00d3LOGO ALCANCE APLICACI\u00d3N DEFINICIONES <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | FASE DE PREDISE\u00d1O <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | FASE DE DISE\u00d1O <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | FASE DE MONTAJE <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | FASE DE OCUPACI\u00d3N\/FUNCIONAMIENTO <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | REFERENCIAS <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | ANEXO NORMATIVO AGU\u00cdA PARA EL DESARROLLO DE DIRECTRICEST\u00c9CNICAS COMPLEMENTARIAS PARA ELPROCESO DE COMMSSIONING <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | ANEXO INFORMATIVO BDIAGRAMA DE FLUJO DEL PROCESO DECOMMISSIONING <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | ANEXO INFORMATIVO CCOSTE Y BENEFICIOS DEL PROCESO DECOMMISSIONING <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | ANEXO INFORMATIVO DMATRIZ DE DOCUMENTACI\u00d3N DEL PROCESO DECOMMISSIONING <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | ANEXO INFORMATIVO ESOLICITUD DE CUALIFICACIONES PARA ELPROCESO DE COMMISSIONING <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | ANEXO INFORMATIVO FFUNCIONES Y RESPONSABILIDADES <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | ANEXO INFORMATIVO GPLAN DE COMMISSIONING <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | ANEXO INFORMATIVO HPLAN DE CONFORMIDAD <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | ANEXO INFORMATIVO IGU\u00cdA PARA LOS TALLERES DEFORMULACI\u00d3N DE LOS OPR <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | ANEXO INFORMATIVO JREQUERIMIENTOS DE LA PROPIEDAD <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | ANEXO INFORMATIVO KBASES DE DISE\u00d1O (BOD) <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | ANEXO INFORMATIVO LESPECIFICACIONES <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | ANEXO INFORMATIVO MLISTAS DE VERIFICACIONES DE MONTAJE <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | ANEXO INFORMATIVO NEJEMPLOS DE MUESTREOS DE CALIDAD <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | ANEXO INFORMATIVO OMANUAL DE SISTEMAS <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | ANEXO INFORMATIVO PMANUAL Y NECESIDADES DE FORMACI\u00d3N <\/td>\n<\/tr>\n | ||||||
74<\/td>\n | ANEXO INFORMATIVO QINFORMACI\u00d3N DESCRIPCI\u00d3N DE ADENDAS <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | Back Cover <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" ASHRAE Spanish – Guideline 0-2019 — The Commissioning ProcessS<\/b><\/p>\n |