{"id":247524,"date":"2024-10-19T16:17:34","date_gmt":"2024-10-19T16:17:34","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-60794-2-102011\/"},"modified":"2024-10-25T11:24:47","modified_gmt":"2024-10-25T11:24:47","slug":"bs-en-60794-2-102011","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-60794-2-102011\/","title":{"rendered":"BS EN 60794-2-10:2011"},"content":{"rendered":"
IEC 60794-2-10:2011 covers simplex and duplex optical fibre cables for indoor use except for cables used in terminated assemblies specified by IEC 60794-2-50. The requirements of the Sectional specification IEC 60794-2 are applicable to cables covered by this standard. The main changes with respect to the previous edition are as follows: – A new clause has been introduced: Clause 4 – Dimensions; – Test conditions and requirements have been made more accurate; – The new Subclause 5.5 has been added to give useful figures. This publication is to be read in conjunction with \/2, \/2 and \/2.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
6<\/td>\n | English \n CONTENTS <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 3 Construction 3.1 General 3.2 Optical fibres and primary coating 3.3 Buffer 3.4 Ruggedised fibre 3.5 Slotted core Tables \n Table 1 \u2013 Dimensions of buffered fibres <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 3.6 Tube 3.7 Stranded loose tube 3.8 Ribbon structure 3.9 Strength and anti-buckling members 3.10 Ripcord 3.11 Sheath 3.12 Sheath marking 3.13 Identification 3.14 Examples of cable constructions 4 Dimensions \u2013 Optical fibres and primary coating <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 5 Tests 5.1 General 5.2 Dimensions 5.3 Mechanical requirements <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 5.4 Environmental requirements 5.5 Transmission requirements Table 2 \u2013 Temperature cycling conditions Table 3 \u2013 Common single-mode optical fibre requirements <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | Table 4 \u2013 Cabled fibre attenuation requirements for B1.1 optical fibre Table 5 \u2013 Cabled fibre attenuation requirements for B1.3 optical fibre Table 6 \u2013 Cabled fibre attenuation requirements for B6_a optical fibre Table 7 \u2013 Cabled fibre attenuation requirements for B6_b optical fibre <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 5.6 Fire performance Table 8 \u2013 Common multimode optical fibre requirements Table 9 \u2013 Cabled fibre attenuation requirements for A1a and A1b optical fibres <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | Annex A (informative) Examples of some types of cable construction \n Figures \n Figure A.1 \u2013 Simplex loose non-buffered fibre cable Figure A.2 \u2013 Simplex ruggedised fibre cable Figure A.3 \u2013 Duplex loose non-buffered fibre cable <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | Figure A.4 \u2013 Duplex ruggedised fibre cable Figure A.5 \u2013 Duplex ruggedised fibre zip cord Figure A.6 \u2013 Duplex flat cable <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Figure A.7 \u2013 Duplex round cable Figure A.8 \u2013 Simplex and duplex rectangular cables <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Annex B (informative) Family specification of indoor cables – simplex and duplex cables \n Table B.1 \u2013 Cable description <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Table B.2 \u2013 Cable element Table B.3 \u2013 Cable construction <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | Table B.4 \u2013 Installation and operating conditions Table B.5 \u2013 Tests applicable <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Optical fibre cables – Indoor optical fibre cables. Family specification for simplex and duplex cables<\/b><\/p>\n |