{"id":255453,"date":"2024-10-19T16:53:14","date_gmt":"2024-10-19T16:53:14","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-13757-32018\/"},"modified":"2024-10-25T12:20:52","modified_gmt":"2024-10-25T12:20:52","slug":"bs-en-13757-32018","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-13757-32018\/","title":{"rendered":"BS EN 13757-3:2018"},"content":{"rendered":"
This draft European Standard specifies application protocols for communication systems for meters and remote reading of meters. This draft European Standard specifies application protocols, especially the M-Bus application protocol. This draft European Standard is intended to be used with the lower layer specifications determined in EN 13757-2, EN 13757-4, EN 13757-5, EN 13757-6 and prEN 13757-7.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 1 95BScope 2 96BNormative references 3 97BTerms and definitions <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 4 98BAbbreviations and symbols 4.1 110BAbbreviations <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 4.2 111BSymbols 5 99BSelection of an application protocol 6 100BM-Bus protocol 6.1 112BGeneral <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 6.2 113BM-Bus data record 6.3 114BData Information Block (DIB) 6.3.1 126BGeneral 6.3.2 127BData Information Field (DIF) 6.3.3 128BData field <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 6.3.4 129BFunction field 6.3.5 130BStorage number <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 6.3.6 131BExtension bit (E) 6.3.7 132BData Information Field Extension (DIFE) 6.3.8 133BTariff information <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 6.3.9 134BSubunit information 6.4 115BValue Information Block (VIB) 6.4.1 135BGeneral <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 6.4.2 136BPrimary VIFs (main table) <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 6.4.3 137BVIF-codes for special purposes <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 6.4.4 138BVIFE-code extension tables 6.4.4.1 145BMain VIFE-code extension table (following VIF = FDh for primary VIF) <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 6.4.4.2 146B2nd level VIFE-code extension table (following VIF = FDh and VIFE = FDh) 6.4.5 139BAlternate VIFE-code extension table (following VIF = FBh for primary VIF) <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 6.4.6 140BCombinable (orthogonal) VIFE-Code extension table <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 6.4.7 141BGeneralized object layer 6.4.8 142BRecord errors <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 6.5 116BManufacturer specific unstructured data block <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 7 101BApplication reset and application select 7.1 117BApplication reset 7.2 118BApplication select with subcode <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 7.3 119BOverview about CI-Fields for Application reset and Application select <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 7.4 120BRules for application selection 7.4.1 143BReset of current slave response <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | 7.4.2 144BErroneous application select 7.5 121BRules for block selection 7.6 122BSelected application block in M-Bus Application protocol 8 102BClock synchronization <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | 9 103BReport of alarm status (slave to master) 10 104BReport of application error 10.1 123BGeneral 10.2 124BStatus field 10.3 125BGeneral application layer errors <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | 11 105BSwitching baud rate for M-Bus link layer according to EN 137572 <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | 12 106BSynchronize action 13 107BManufacturer specific protocols 14 108BOther application protocols 15 109BImage transfer <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | Annex A 86B(normative)Coding of data records <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | Annex B 87B(normative)Interpretation of hex-codes Ah\u2013Fh in BCD-data fields B.1 0BGeneral description standard reference B.1.1 23BGeneral B.1.2 24BPurpose B.2 1BDefinition B.2.1 25BHex code meanings B.2.2 26BLCD-decoding table <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | Annex C 88B(normative)VIF coding for special units C.1 2BNon-metric units C.2 3BPlain text units <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | C.3 4BRemote enablement\/disablement of valve\/breaker <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | Annex D 89B(informative)Alarm protocol D.1 5BM-Bus according EN 137572 D.2 6BWireless M-Bus according to EN 137574 <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | Annex E 90B(informative)Special sequences for M-Bus devices E.1 7BVIF\/VIFE\/VIFE = FDh 97h 1Dh (error flag) <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | E.2 8BVIF\/VIFE\/VIFE = FDh 9Fh 1Dh for passing remote control on a node <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | E.3 9BClock synchronization <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | Annex F 91B(normative)Transmission of profiles F.1 10BThe standard load profile F.2 11BThe M-Bus compact profile F.2.1 27BGeneral <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | F.2.2 28BThe base value and base parameter F.2.3 29BThe base time F.2.4 30BStructure of the compact profile <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | F.2.5 31BTypes of compact profile F.2.6 32BCompact profile with register numbers (orthogonal VIFE = 1Eh) <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | F.2.7 33BCompact profile (orthogonal VIFE = 1Fh) F.2.8 34BInverse compact profile (orthogonal VIFE = 13h) <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | Annex G 92B(normative)Compact M-Bus frame G.1 12BGeneral G.2 13BCI-fields of the Full and the Compact M-Bus frame G.2.1 35BGeneral <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | G.2.2 36BFull M-Bus frame G.2.3 37BM-Bus- Compact frame <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | G.2.4 38BM-Bus-Format frame G.3 14BCalculation of the Full-Frame-CRC G.4 15BCalculation of the Format Signature G.5 16BFrame examples G.5.1 39BGeneral <\/td>\n<\/tr>\n | ||||||
64<\/td>\n | G.5.2 40BExample without data header G.5.3 41BExample with short data header, no encryption G.5.4 42BExample with short data header, encryption mode 5 <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | Annex H 93B(normative)Translating M-Bus type record descriptors to OBIS-type record descriptors H.1 17BGeneral H.2 18BTranslation of predefined data record types <\/td>\n<\/tr>\n | ||||||
84<\/td>\n | H.3 19BOnline addition of an entry for the M-Bus to OBIS conversion table <\/td>\n<\/tr>\n | ||||||
85<\/td>\n | Annex I 94B(normative)Image Transfer I.1 20BImage Transfer Phases I.1.1 43BGeneral I.1.2 44BTransfer Preparation <\/td>\n<\/tr>\n | ||||||
86<\/td>\n | I.1.3 45BTransfer Synchronization I.1.4 46BImage Transfer <\/td>\n<\/tr>\n | ||||||
87<\/td>\n | I.1.5 47BImage Validation I.1.6 48BImage Activation I.2 21BCommands for Image Transfer I.2.1 49BGeneral I.2.2 50BCommand and response structure <\/td>\n<\/tr>\n | ||||||
88<\/td>\n | I.2.3 51BFunction Field <\/td>\n<\/tr>\n | ||||||
89<\/td>\n | I.2.4 52BPrepare command I.2.4.1 69BGeneral <\/td>\n<\/tr>\n | ||||||
90<\/td>\n | I.2.4.2 70BImage Identifier field I.2.4.3 71BDate and Time field <\/td>\n<\/tr>\n | ||||||
91<\/td>\n | I.2.4.4 72BPace I.2.4.5 73BSize Information field I.2.4.6 74BMAC field <\/td>\n<\/tr>\n | ||||||
93<\/td>\n | I.2.4.7 75BAdditional Information I.2.5 53BPrepare response <\/td>\n<\/tr>\n | ||||||
94<\/td>\n | I.2.6 54BSynchronize Command I.2.6.1 76BGeneral <\/td>\n<\/tr>\n | ||||||
95<\/td>\n | I.2.6.2 77BCount Down field I.2.7 55BTransfer command I.2.7.1 78BGeneral I.2.7.2 79BBlock number <\/td>\n<\/tr>\n | ||||||
96<\/td>\n | I.2.7.3 80BRemaining field I.2.7.4 81BAdditional Information I.2.7.5 82BImage block I.2.8 56BTransfer Response I.2.9 57BCompletion command <\/td>\n<\/tr>\n | ||||||
97<\/td>\n | I.2.10 58BCompletion response I.2.10.1 83BGeneral I.2.10.2 84BTotal Number of Lost Blocks <\/td>\n<\/tr>\n | ||||||
98<\/td>\n | I.2.10.3 85BLost Blocks Field I.2.11 59BState command I.2.12 60BState Response <\/td>\n<\/tr>\n | ||||||
99<\/td>\n | I.2.13 61BValidate command <\/td>\n<\/tr>\n | ||||||
100<\/td>\n | I.2.14 62BValidate Response I.2.15 63BActivate command <\/td>\n<\/tr>\n | ||||||
101<\/td>\n | I.2.16 64BActivate Response <\/td>\n<\/tr>\n | ||||||
102<\/td>\n | I.2.17 65BTerminate Command I.2.18 66BTerminate Response <\/td>\n<\/tr>\n | ||||||
103<\/td>\n | I.2.19 67BActive Images Command I.2.20 68BActive Images Response I.3 22BOverview Image Transfer <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Communication systems for meters – Application protocols<\/b><\/p>\n |