{"id":265678,"date":"2024-10-19T17:43:26","date_gmt":"2024-10-19T17:43:26","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iso-8573-22018-tc\/"},"modified":"2024-10-25T13:41:24","modified_gmt":"2024-10-25T13:41:24","slug":"bs-iso-8573-22018-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iso-8573-22018-tc\/","title":{"rendered":"BS ISO 8573-2:2018 – TC"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
76<\/td>\n | National foreword <\/td>\n<\/tr>\n | ||||||
81<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions 4 Units <\/td>\n<\/tr>\n | ||||||
84<\/td>\n | 5 Reference conditions 6 Guidance for selection of sampling method 7 Method A \u2014 Description, measuring procedure and calculation of results 7.1 Description of sampling equipment and method 7.1.1 General 7.1.2 Sampling equipment <\/td>\n<\/tr>\n | ||||||
86<\/td>\n | 7.2 Sampling procedure 7.2.1 Start-up 7.2.2 Stabilizing sampling filter <\/td>\n<\/tr>\n | ||||||
87<\/td>\n | 7.2.3 Oil measurement 7.2.4 Oil\/water measurements <\/td>\n<\/tr>\n | ||||||
89<\/td>\n | 7.2.5 Air flow-rate (discharge) 7.2.6 Temperature 7.3 Calculation of test results 7.3.1 General 7.3.2 Oil content 8 Method B \u2014 Description, measuring procedure and calculation of results 8.1 General description of sampling equipment and method <\/td>\n<\/tr>\n | ||||||
90<\/td>\n | 8.1.1 Sampling disc 8.1.2 Sampling disc support 8.1.3 Pipes and valves <\/td>\n<\/tr>\n | ||||||
91<\/td>\n | 8.1.4 Sampling disc holder 8.1.5 Construction materials 8.2 Sampling equipment arrangement 8.2.1 Sampling equipment Method B1 \u2014 Full flow sampling 8.2.2 Sampling equipment Method B2 \u2014 Partial flow sampling <\/td>\n<\/tr>\n | ||||||
92<\/td>\n | 8.2.3 Equipment set-up for isokinetic sampling <\/td>\n<\/tr>\n | ||||||
93<\/td>\n | 8.2.4 Compressed air flow-rates for isokinetic conditions <\/td>\n<\/tr>\n | ||||||
95<\/td>\n | 8.3 Equipment and sampling disc preparation 8.3.1 Equipment preparation 8.3.2 Oil vapour 8.3.3 Temperature 8.3.4 Handling <\/td>\n<\/tr>\n | ||||||
96<\/td>\n | 8.3.5 Sampling disc contamination check 8.4 Compressed air sampling procedure 8.4.1 Typical sampling Method B1 <\/td>\n<\/tr>\n | ||||||
97<\/td>\n | 8.4.2 Typical sampling Method B2 <\/td>\n<\/tr>\n | ||||||
98<\/td>\n | 9 Analytical procedure for Methods B1 and B2 9.1 General 9.2 Apparatus 9.2.1 Usual laboratory glassware 9.2.2 Infrared spectrometer (IR) 9.2.3 Gas chromatograph and flame ionization detector (GC-FID) 9.3 Analytical procedure linearity check 9.4 Analytical procedure \u2014 Oil recovery coefficient 9.5 Limit of detection 9.6 Calculation of test results 9.7 General <\/td>\n<\/tr>\n | ||||||
99<\/td>\n | 10 Presentation of results 11 Uncertainty of the method <\/td>\n<\/tr>\n | ||||||
100<\/td>\n | Annex A (informative) Typical test report <\/td>\n<\/tr>\n | ||||||
101<\/td>\n | Annex B (informative) Typical equipment layout and dimensional details <\/td>\n<\/tr>\n | ||||||
105<\/td>\n | Annex C (informative) Example IR analysis and calculation of test results for Method B <\/td>\n<\/tr>\n | ||||||
115<\/td>\n | Annex D (informative) Example GC FID analysis and calculation of test results for Method B <\/td>\n<\/tr>\n | ||||||
126<\/td>\n | Annex E (informative) Alternative oil aerosol detection <\/td>\n<\/tr>\n | ||||||
127<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Tracked Changes. Compressed air. Contaminant measurement – Oil aerosol content<\/b><\/p>\n |